Controller Enclosure
Overview
This function displays the Controller Enclosure (CE) information.
Display Contents
The CE information is displayed.

CE List
The CE list is displayed only for the ETERNUS DX900 S6 or the ETERNUS DX8900 S6.
Item | Description | |||
---|---|---|---|---|
Enclosure |
The CE number is displayed. Click this item to display the [Controller Enclosure Detail] Screen. CE#n |
|||
Status |
The CE status is displayed. Refer to Component Status for details. |
|||
Cache Mode |
The current status and the factor of the cache are displayed. The normal status is "Write Back Mode".
|
[Controller Enclosure Detail] Screen
[Summary] Tab
CE#n Information (for the ETERNUS DX900 S6 or the ETERNUS DX8900 S6)CE Information (for the ETERNUS DX600 S6 or the ETERNUS DX8100 S6)
Item | Description |
---|---|
Status |
The CE status is displayed. Refer to Component Status for details. |
Cache Mode |
The current status and the factor of the cache are displayed. Write Back Mode Write Through (Pinned Data) Write Through (Battery) Write Through (Maintenance) Write Through (1CM) |
Serial Number |
The serial number of the CE is displayed. |
Other Information |
Other information of the CE is displayed. |
Location |
The installation location of the thermal sensor is displayed. Ambient Temp Internal Temp |
Status |
The thermal sensor status is displayed. Normal Warning Maintenance Error Unknown |
Error Code |
The error code of the thermal sensor is displayed. |
Sensor 1 |
The temperature of CM#0 is displayed. If the thermal information is not available due to problem such as a sensor failure, a "-" (hyphen) is displayed. C: Celsius temperature F: Fahrenheit temperature |
Sensor 2 |
The temperature of CM#1 is displayed. If the thermal information is not available due to problem such as a sensor failure, a "-" (hyphen) is displayed. C: Celsius temperature F: Fahrenheit temperature |
[Front View] Tab (for the ETERNUS DX600 S6, the ETERNUS DX900 S6, the ETERNUS DX8100 S6, and the ETERNUS DX8900 S6)
- CE#n Front View
Item | Description |
---|---|
(Storage system image) |
The front view of the CE that is installed in the storage system is displayed. Twenty-four drives can be installed. If drives are not installed, the field is blank. The drive status is displayed with an icon. Click the drive image to display the [Drive Detail] screen. Refer to Component Status for details. |
CE#n Internal Parts Information
Item | Description |
---|---|
Parts |
The Battery Unit (BTU) number and the Battery Control Unit (BCU) number are displayed. Click the BTU number to display the [Battery Unit Detail] screen. Click the BCU number to display the [Battery Charger Unit Detail] screen. BTU#n BCU#n |
Status |
The status of each component is displayed. Refer to Component Status for details. |
Status Code |
The status code of each component is displayed. |
Error Code |
The error code of each component is displayed. |
CE#n Drives Information (for the ETERNUS DX900 S6 or the ETERNUS DX8900 S6)CE Drives Information (for the ETERNUS DX600 S6 or the ETERNUS DX8100 S6)
Item | Description |
---|---|
Slot No. |
The slot number (0 to 23) is displayed. Click this item to display the [Drive Detail] screen. |
Status |
The drive status is displayed. Refer to Drive Status for details. |
Capacity |
The capacity of the drive is displayed. Caution
|
Speed |
The drive speed is displayed. For SSD, NVMe SSD, SSD SED, or NVMe SSD SED, a "-" (hyphen) is displayed. |
Type |
The drive type is displayed. Refer to Drive Type for details. |
Usage |
The usage of the drive is displayed.
|
RAID Group |
When the drive belongs to a RAID group, the RAID group number and the RAID group name are displayed. However, if the drive usage is "Dedicated Hot Spare", the RAID group number and the RAID group name are displayed even when the drive is not used as a hot spare. Click this item to display the [RAID Group Detail] Screen. When the usage is not "Dedicated Hot Spare" and the drive is not registered in a RAID group, a "-" (hyphen) is displayed. |
Health |
A "-" (hyphen) is displayed in the following conditions:
|
[Rear View] Tab
CE#n Rear View (for the ETERNUS DX900 S6 or the ETERNUS DX8900 S6)CE Rear View (for the ETERNUS DX600 S6 or the ETERNUS DX8100 S6)
Item | Description |
---|---|
(Storage system image) |
The rear view of the CE that is installed in the storage system is displayed. The CM, CA, DA, BUD, and CPSU states are displayed with an icon. The components vary depending on the model. Click the CM number to display the [Controller Module Detail] screen. Click the CA number to display the [Channel Adapter Detail] screen. Click the DA number to display the [Drive Adapter Detail] screen. Click the BUD number to display the [Bootup and Utility Device Detail] screen. Click the CPSU number to display the [PSU/CPSU Detail] screen. Refer to Component Status for details. |
CE#n Internal Parts Information (for the ETERNUS DX900 S6 or the ETERNUS DX8900 S6)CE Internal Parts Information (for the ETERNUS DX600 S6 or the ETERNUS DX8100 S6)
Item | Description |
---|---|
Parts |
The CM number, the CA number, the DA number, the BUD number, and the CPSU number are displayed. The components vary depending on the model. Click the CM number to display the [Controller Module Detail] screen. Click the CA number to display the [Channel Adapter Detail] screen. Click the DA number to display the [Drive Adapter Detail] screen. Click the BUD number to display the [Bootup and Utility Device Detail] screen. Click the CPSU number to display the [PSU/CPSU Detail] screen. CM#n CM#n CA#n CM#n DA#n CM#n BUD#n CPSU#n |
Status |
The status of each component is displayed. Refer to Component Status for details. |