Setup Power Management

Overview

This function connects the external input device and controls (shuts down) the storage system power.

Caution
  • If this function is enabled by mistake, the storage system may shut down unexpectedly. Make sure to check setting contents before performing settings.

Settings

In this screen, specify the settings to shut down the storage system power by connecting it to the external input device.

Power Control by External Device

Item Description Setting values

RCIL

Select whether to "Enable" or "Disable" the RCIL connection.

Enable

Disable (Default)

Auto Power

Select whether to "Enable" or "Disable" the power interlock mode (the function to automatically power on when the power is supplied).

Enable

Disable (Default)

Power Resume

Select whether to "Enable" or "Disable" the auto power recovery mode (the function to automatically power on at power recovery after a power failure).

Enable

Disable (Default)

Connection Module Settings

Item Description

SCCI

Select the checkbox for each module to enable power management by an external input device. This checkbox is not selected by default.

  • For the ETERNUS DX8100 S6, checkboxes for "CM#0" and "CM#1"

  • For the ETERNUS DX900 S6 or the ETERNUS DX8900 S6, checkboxes for "SVC#0" and "SVC#1"

Operating Procedures

  1. Click [Setup Power Management] in [Action].

  2. Specify the parameters, and click the [Set] button.

    → A confirmation screen appears.

  3. Click the [OK] button.

    → Setting of the power management starts.