Setup Debug Mode

Overview

This function sets the trace level to store the storage system information and the collection mode for panic dumps when errors occur.

Caution
  • If you need to change the debug mode settings, follow the Support Department instructions.

Note
  • Trace information is included in the panic dump.

  • To collect a panic dump, use the [Export/Delete Panic Dump] function.

Settings

In this screen, specify the conditions for collecting the storage system information.

Master Trace Level Settings

Item Description Setting values

Master Trace Level

Set the master trace level.

  • Off

    Does not save a trace. Equivalent to level "0xFF".

  • Standard

    The firmware trace information is saved. Equivalent to level "0x06".

  • Detail

    All the firmware trace are saved. Equivalent to level "0x00".

  • Specification

    The firmware traces according to the user specified level are saved.

Off

Standard (Default)

Detail

Specification

Level

When selecting "Specification" for the master trace level, input the trace level.

2-digit hexadecimal

0x00 - 0xFF

0x06 (Default)

Level by Group

Item Description Setting values

Group ID

The group ID (0x00 to 0xFF) is displayed.

Level

Input the trace level for each group ID.

2-digit hexadecimal

0x00 - 0xFF

0x06 (Default)

Panic

Item Description Setting values

Collection Mode

Select the collection mode for panic dump.

  • Nose and Tail Mode

    The latest and oldest panic dumps are saved.

  • Fortnight Mode

    The first and second panic dumps are saved.

  • Off

    Does not save panic dumps.

Nose and Tail Mode (Default)

Fortnight Mode

Off

Operating Procedures

  1. Click [Setup Debug Mode] in [Action].

  2. Specify the parameters, and click the [Set] button.

    → A confirmation screen appears.

  3. Click the [OK] button.

    → The debug mode is set.

  4. Click the [Done] button to return to the [System Settings] screen.