Eco-mode Schedule (Thin Provisioning Pool)

Overview

This function displays the set state of the Eco-mode that is applied for the Thin Provisioning Pool (TPP).

Caution
  • When using the Thin Provisioning function, "Enable" the Thin Provisioning. Refer to the [Set Thin Provisioning] function for details.

Note
  • TPPs with either or both of Deduplication and Compression enabled are not displayed in the TPP list.

  • To check whether the Thin Provisioning function is enabled or disabled, use the [Settings (Thin Provisioning)] function.

  • To use the Eco-mode, it is required to create the common Eco-mode setup and Eco-mode schedule. Refer to the [Modify Eco-mode General Setting] function and the [Create Eco-mode Schedule] function for details.

  • To assign the Eco-mode schedule to TPPs, use the [Eco-mode Schedule (Thin Provisioning Pool)] function.

Display Contents

In this screen, the set state of the Eco-mode that is applied for the TPP is displayed in a list.

TPP List

Item Description

No.

The TPP number is displayed.

Click this item to display the [Thin Provisioning Pool Detail] Screen ([Basic] Tab).

Name

The TPP name is displayed.

Click this item to display the [Thin Provisioning Pool Detail] Screen ([Basic] Tab).

Drive Type

The type of drive that configures the TPP is displayed.

Refer to Drive Type for details.

RAID Level

The level of RAID group that configures the TPP is displayed.

Refer to RAID Level for details.

Status

The TPP status is displayed.

Refer to Thin Provisioning Pool Status for details.

Used Status

The used status of the TPP or the Data Container Volume is displayed.

  • Normal

    TPP usage does not exceed the "Attention" threshold.

  • Attention

    TPP usage exceeds the "Attention" threshold but does not exceed the "Warning" threshold.

    Or the Data Container Volume usage is 80 % or larger.

  • Warning

    TPP usage exceeds the "Warning" threshold.

Total Capacity

The total capacity of TPP is displayed.

Eco-mode Schedule

The Eco-mode schedule name that is assigned to the TPP is displayed.

If the Eco-mode is controlled with Fujitsu ETERNUS SF Storage Management Software, "External" is displayed.

When no Eco-mode schedule has been assigned, the field is blank.

Eco-mode Action

The Eco-mode schedule action status is displayed.

When no Eco-mode schedule has been assigned, a "-" (hyphen) is displayed.

  • Drive power off

    The power for the drive is turned off during Eco-mode operation.

  • Drive motor off

    The drive motor is stopped during Eco-mode operation.

  • Drive always on

    The Eco-mode is disabled and the drive is always on.

Motor Status

The drive motor status is displayed.

  • Active

    The drive motors are activated.

  • In the Boot Process

    The drive motors are starting up.

  • Idle

    The drive motors are stopped.

  • In the Stop Process

    The drive motors are being stopped.

  • Power Off

    The drive power is being turned off.