Setup Event Notification
Overview
This function specifies whether to report events that are detected in the storage system.
There are six methods for event notification: Host Sense Key Code Qualifier, SNMP Trap, E-Mail, syslog, REMCS, and AIS Connect.
A notification setting can be selected for each type of event.
- For the SNMP Trap notification, performing the following functions is required.
[Setup SNMP Agent Basic Interface]
[Setup SNMP Manager]
[Setup SNMP Agent MIB Access View]
[Setup SNMP Agent User]
[Setup SNMP Agent Community]
[Setup SNMP Agent Trap]
For E-Mail notification, performing [Setup E-Mail Notification] is required.
For syslog notification, performing [Setup Syslog] is required.
For REMCS notification, performing [Setup Remote Support] is required.
For AIS Connect notification, performing [Setup AIS Connect Environment] is required.
- If ETERNUS SF Storage Cruiser is used and configured to automatically obtain the component status of the storage system, event notifications by SNMP traps for the following events are automatically enabled (notified).
Remote Path Error of no Data Transfer
Recovery module
Temperature restoration
FC CA Port Link Status Changed
iSCSI CA Port Link Status Changed
Remote Path Recovery
Events whose notification is enabled by default, but is disabled manually
- If the storage system is deleted from ETERNUS SF Storage Cruiser, event notifications of the SNMP traps revert to the default value. However, if the event notifications of the SNMP traps are changed from a storage system after being automatically changed, the event notifications do not revert to the default value even if the storage system is deleted.
User Privileges
Availability of Executions in the Default Role
Default role | Availability of executions |
---|---|
Monitor | |
Admin | |
StorageAdmin | |
AccountAdmin | |
SecurityAdmin | |
Maintainer |
Refer to "User Roles and Policies" for details on the policies and roles.
Settings
The events are classified into three levels: "Error Severity Level", "Warning Level", and "Informational Level".
Click the [Setting based on Severity] tab, [Error Severity Level] Tab, [Warning Level] Tab, or [Informational Level] Tab to display the setting fields for each level.
Setting based on Severity
Select whether to notify of an event by levels. Checkboxes are displayed for selectable notification methods.
When enabling the notification, select the method from "Host Sense Key Code Qualifier", "SNMP Trap", "E-Mail", "syslog", "REMCS", or "AIS Connect" (multiple selections can be made).
When setting the notification method for each event, move on to the setting fields for each level.
Item | Description | Setting values | |
---|---|---|---|
All Error Events |
Select whether to notify when an error level event occurs. When notifying, select the notification method. By selecting or clearing the checkbox, the same setting can be applied for all the events displayed in the [Error Severity Level] Tab. Display contents: Selected (normal checkbox): Notify all events Selected (lighter colored checkbox): Some events are notified and some events are not notified Cleared: No events are notified |
Selected: Notify all the events Cleared: No events are notified |
|
All Warning Events |
Select whether to notify when a warning level event occurs. When notifying, select the notification method. By selecting or clearing the checkbox, the same setting can be applied for all the events displayed in the [Warning Level] Tab. Display contents: Selected (normal checkbox): Notify all events Selected (lighter colored checkbox): Some events are notified and some events are not notified Cleared: No events are notified |
Selected: Notify all the events Cleared: No events are notified |
|
All Informational Events |
Select whether to notify when an informational level event occurs. When notifying, select the notification method. By selecting or clearing the checkbox, the same setting can be applied for all the events displayed in the [Informational Level] Tab. Display contents: Selected (normal checkbox): Notify all events Selected (lighter colored checkbox): Some events are notified and some events are not notified Cleared: No events are notified |
Selected: Notify all the events Cleared: No events are notified |
|
Individual Settings within Severity Level |
"Yes" is displayed when the target notification method ("Host Sense Key Code Qualifier", "SNMP Trap", "E-Mail", "syslog", "REMCS" or "AIS Connect") is specified for any event in "Error Severity Level", "Warning Level", or "Informational Level", if not, "No" is displayed. |
||
Blink Fault LED at warning |
Select "Enable" when setting the Fault LED in the front panel to blink while a warning level event occurs, or select "Disable" when setting the Fault LED not to blink. |
Enable (Default) Disable |
|
Turn on Fault LED when redundant copy is completed |
Select "Enable" when setting the Fault LED of the drive to turn on when a redundant copy is complete, or select "Disable" when setting the Fault LED not to turn on. Caution
|
Enable Disable (Default) |
|
Display parts (except drive) with error status on LCD |
Select "Enable" when displaying the part (other than drive) error message on the LCD, or select "Disable" not to display the message on the LCD. This item is displayed only for the ETERNUS DX900 S5 or the ETERNUS DX8900 S4. |
Enable (Default) Disable |
|
Display parts (except drive) with warning status on LCD |
Select "Enable" when displaying the part (other than drive) warning message on the LCD, or select "Disable" not to display the message on the LCD. This item is displayed only for the ETERNUS DX900 S5 or the ETERNUS DX8900 S4. |
Enable (Default) Disable |
|
Display drives with error status on LCD |
Any Time |
Select "Enable" when displaying the drive error message on the LCD at any time regardless of whether the hot spare disk exists, or select "Disable" if the message should not be displayed. This item is displayed only for the ETERNUS DX900 S5 or the ETERNUS DX8900 S4. |
Enable (Default) Disable |
when HS<0 |
Select "Enable" when displaying the drive error message only if a drive error occurs when the available hot spare disk is "0", or select "Disable" if the message should not be displayed. This item can be selected only when the "Display drives with error status on LCD (Any Time)" is disabled. This item is displayed only for the ETERNUS DX900 S5 or the ETERNUS DX8900 S4. |
Enable Disable (Default) |
|
Display drives with warning status on LCD |
Any Time |
Select "Enable" when displaying the drive warning message on the LCD at any time regardless of whether the hot spare disk exists, or select "Disable" if the message should not be displayed. This item is displayed only for the ETERNUS DX900 S5 or the ETERNUS DX8900 S4. |
Enable (Default) Disable |
when HS<0 |
Select "Enable" when displaying the drive warning message only if a drive warning occurs when the available hot spare disk is "0", or select "Disable" if the message should not be displayed. This item can be selected only when the "Display drives with warning status on LCD (Any Time)" is disabled. This item is displayed only for the ETERNUS DX900 S5 or the ETERNUS DX8900 S4. |
Enable Disable (Default) |
For the ETERNUS DX900 S5 or the ETERNUS DX8900 S4, the notification methods that are specified in this function determine whether to display the LCD message on the Overview screen and the Operation Panel.
Function Button
Button | Description |
---|---|
[System Defaults] |
Returns the event notification to the "Initial Setting List". |
[REMCS Defaults] |
Specifies the event notification of the "REMCS Recommended Setting List". |
[Error Severity Level] Tab
Select whether to notify of the error event for each event type.
When enabling the notification, select the method from "Host Sense Key Code Qualifier", "SNMP Trap", "E-Mail", "syslog", "REMCS", or "AIS Connect" (multiple selections can be made).
Item | Description | Setting values | |||
---|---|---|---|---|---|
Parts Error |
Select whether to notify when a failure occurs in a part other than the drive. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Drive Error |
Select whether to notify when a failure occurs in a non-protected (non-shielded) drive for each condition that is described below. When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
Drive Error of HDD Shield |
Select whether to notify when a failure occurs in a protected (shielded) drive for each condition that is described below. When notifying, select the notification method.
Note
|
Selected: Notify Cleared |
|||
Succeeded HDD Shield |
Select whether to notify when a failed drive is diagnosed as being available by the protect (shield) function and is activated in the storage system. When notifying, select the notification method. Note
|
Selected: Notify Cleared |
|||
Temperature Error |
Select whether to notify when a temperature error status is detected by the sensor. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
End of battery life |
Select whether to notify when a battery expires. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Rebuild/Copyback w/ redundant |
Select whether to notify when rebuilding or copy backing (with redundancy) (*1) is performed. When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
Rebuild/Copyback w/o redundant |
Select whether to notify when rebuilding or copy backing (without redundancy) (*1) occurs for each condition shown below. When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
Redundant |
Select whether to notify when a redundant copy starts or ends abnormally for each condition shown below. When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
Complete Redundant Copy |
Select whether to notify when a redundant copy and isolation of the non-protected (non-shielded) drive from the storage system are complete. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Complete Redundant Copy of HDD Shield |
Select whether to notify when a redundant copy and isolation of the protected (shielded) drive from the storage system are complete. When notifying, select the notification method. Note
|
Selected: Notify Cleared |
|||
Complete rebuild |
Select whether to notify when a bad sector (*1) is detected in the hot spare where rebuilding is completed. When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
Bad data |
Select whether to notify when a bad sector is detected in the drive. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Pinned data |
Select whether to notify when pinned data (*1) is detected or disappears. When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
Not Ready |
Select whether to notify when the storage system is in the "Not Ready" state (*1). When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
Remote Path Error during Data Transfer |
Select whether to notify when an error occurs in a copy path and an REC session that is not suspended exists. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Remote Path Error of no Data Transfer |
Select whether to notify when an error occurs in a copy path and an REC session that is in one of the following conditions exists. When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
REC Buffer Halt (Path Error) |
Select whether to notify when an REC buffer halt caused by copy path error occurs. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
REC Buffer Halt (Overload) |
Select whether to notify when an REC buffer halt caused by overload occurs. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
REC Buffer Halt (Other Error) |
Select whether to notify when an REC buffer halt caused by an error occurs. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Copy Session Error |
Select whether to notify when an error is detected in the Advanced Copy session or when a failed Advanced Copy session is recovered. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Thin Provisioning Pool Rate |
Select whether to notify when the TPP usage changes (*1). When notifying, select the notification method.
Note
|
Selected: Notify Cleared |
|||
SED Network Error |
Select whether to notify when the communication between the storage system and the key server is disconnected. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
NAS I/O Error |
Select whether to notify when an I/O error is detected in the NAS system. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
NAS Snapshot Error |
Select whether to notify when a snapshot acquisition error is detected in the NAS system. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
Extended System Volume Error |
Select whether to notify the error status of the NAS expanded system volume (such as the unmount state, access error, or out of capacity) for the NAS system. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
Disconnect Storage Cluster Controller |
Select whether to notify when the Storage Cluster controller has been specified and a communication error with the paired storage system is detected. When notifying, select the notification method. This item is only displayed when "Enable" is selected for the Storage Cluster function. |
Selected: Notify Cleared |
|||
Data Access Failed During RAID Group Redundancy Loss |
Select whether to notify of data access failure when the RAID group redundancy is lost. When notifying, select the notification method. |
Selected: Notify Cleared |
[Warning Level] Tab
Select whether to notify of a warning event for each event type.
When enabling the notification, select the method from "Host Sense Key Code Qualifier", "SNMP Trap", "E-Mail", "syslog", or "AIS Connect" (multiple selections can be made).
Item | Description | Setting values | |||
---|---|---|---|---|---|
Parts Warning |
Select whether to notify when a warning level event occurs in a part other than the drive. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Drive Warning |
Select whether to notify when a warning level event occurs in a non-protected (non-shielded) drive for each condition that is described below. When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
Drive Warning of HDD Shield |
Select whether to notify when a warning level event occurs in a protected (shielded) drive for each condition that is described below. When notifying, select the notification method.
Note
|
Selected: Notify Cleared |
|||
Temperature Warning |
Select whether to notify when a temperature warning status is detected by the sensor. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Battery life Warning |
Select whether to notify of a battery expiration in advance (*1). When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
NAS I/O Warning |
Select whether to notify when a warning level I/O error (read error from or write error to the metadata area or the bitmap area) is detected in the NAS system. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
NAS Connection Error |
Select whether to notify when a NAS connection error (receiving incorrect message or blocked file system) is detected in the NAS system. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
Out of NAS Capacity |
Select whether to notify when one of the events described below occurs. When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
NAS Quota Limit Exceeded |
Select whether to notify when the quota setting information (such as Drive Used Size or File Count) for NAS user volumes or shared folders exceeds the threshold in the NAS system. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. Note
|
Selected: Notify Cleared |
|||
Extended System Volume Warning |
Select whether to notify when used capacity of the NAS expanded system volume in the NAS system exceeds 90%. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
RAID Group Redundancy Lost or Recovered |
Select whether to notify when the RAID group redundancy is lost or when the RAID group redundancy is recovered. When notifying, select the notification method. |
Selected: Notify Cleared |
[Informational Level] Tab
Select whether to notify of an informational event for each event type.
When enabling the notification, select the method from "SNMP Trap", "E-Mail", "syslog", or "AIS Connect" (multiple selections can be made).
Item | Description | Setting values | |||
---|---|---|---|---|---|
Recovery module |
Select whether to notify when the failed part is recovered by taking actions such as replacement. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Temperature restoration |
Select whether to notify when a temperature error or warning status is recovered to the normal status. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
User login/logout |
Select whether to notify when a user login/logout is detected. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Operated RAID Group |
Select whether to notify when the RAID group is created or deleted. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Added/Released Hot Spare |
Select whether to notify when the hot spare disk is registered or released. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Operated Volume |
Select whether to notify when the volume is created or deleted. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Power off/on Apply Firmware |
Select whether to notify when the storage system is turned off/on or when the hot controller firmware upgrade is performed. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
SDP Usage Rate Over Lv1 |
Select whether to notify when an SDP Policy Level 1 (Informational) event occurs. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
SDP Usage Rate Over Lv2 |
Select whether to notify when an SDP Policy Level 2 (Warning) event occurs. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
SDP Usage Rate Over Lv3 |
Select whether to notify when an SDP Policy Level 3 (Error) event occurs. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Copy Table Size Usage Rate Over |
Select whether to notify when the copy table usage exceeds the threshold. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Trial copy license expired |
Select whether to notify when a copy trial license expiration event occurs. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
Remote Path Recovery |
Select whether to notify when a remote path is recovered after a remote path error (*1) is notified. When notifying, select the notification method.
|
Selected: Notify Cleared |
|||
No Free Space on ODX Buffer Volume |
Select whether to notify when an insufficient free space event for an ODX Buffer volume occurs. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
SED Network Error Recovered |
Select whether to notify when the communication between the storage system and the key server is recovered. When notifying, select the notification method. |
Selected: Notify Cleared |
|||
FC CA Port Link Status Changed |
Select whether to notify when a link down occurs after an FC link is established and the link status is changed. When notifying, select the notification method. Note that a change in the link status due to user operation is not notified. A change in the link status for all FC ports is notified. The notification is reported regardless of the type (FC), the port mode (CA, RA, CA/RA, Initiator), and the transfer rate. The following FC link status types can be detected and notified:
The FC link status can be checked in the [Port Detail] screen. Refer to the [Channel Adapter] function for details. Note
|
Selected: Notify Cleared |
|||
iSCSI CA Port Link Status Changed |
Select whether to notify when a link down occurs after an iSCSI link is established and the link status is changed. When notifying, select the notification method. Note that a change in the link status due to user operation is not notified. A change in the link status for all iSCSI ports is notified. The notification is reported regardless of the port mode (CA, RA, CA/RA) and transfer rate. The following iSCSI link status types can be detected and notified:
The iSCSI link status can be checked in the [Port Detail] screen. Refer to the [Channel Adapter] function for details. Note
|
Selected: Notify Cleared |
|||
Host Login Over |
Select whether to notify when the number of connected hosts for each CA port exceeds the maximum value (256 hosts). When notifying, select the notification method. This item is notified regardless of the CA type (FC, iSCSI, and SAS). |
Selected: Notify Cleared |
|||
NAS Connection Status |
Select whether to notify when the link status for a NAS connection is changed (such as mount, unmount, or recovery of the file system) in the NAS system. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
Out of NAS Capacity |
Select whether to notify when insufficient capacity in the file system (data area) that is allocated by the NAS is detected in the NAS system. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
Out of NAS File Management Domain |
Select whether to notify when insufficient capacity in the management area for the files and the directories of the NAS function is detected in the NAS system. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
Succeed NAS Snapshot |
Select whether to notify when a snapshot acquisition has succeeded in the NAS system. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
Fall below NAS Quota Limit |
Select whether to notify when the quota setting information (such as Drive Used Size or File Count) for NAS user volumes or shared folders becomes less than the threshold in the NAS system. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. Note
|
Selected: Notify Cleared |
|||
NAS CPU Warning |
Select whether to notify when the used rate of the whole CPU in the NAS system exceeds 90%. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
NAS CPU Recovered |
Select whether to notify when the used rate of the whole CPU in the NAS system goes from 90% or more to 80% or less. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
Extended System Volume Recovered |
Select whether to notify when the used capacity of the NAS expanded system volume in the NAS system goes from 90% or more to 80% or less. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
Multipath Status |
Select whether to notify when the NAS port status in the multipath configuration has changed. When notifying, select the notification method. This item is only displayed in a Unified Storage environment. |
Selected: Notify Cleared |
|||
Automatic Change Storage Cluster Active/Standby State |
Select whether to notify when the Storage Cluster status is changed from "Standby" to "Active" or from "Active" to "Standby" with automatic failover or failback. When notifying, select the notification method. This item is only displayed when "Enable" is selected for the Storage Cluster function. |
Selected: Notify Cleared |
|||
Manual Change Storage Cluster Active/Standby State |
Select whether to notify when the Storage Cluster status is changed from "Standby" to "Active" or from "Active" to "Standby" with manual failover or failback. When notifying, select the notification method. This item is only displayed when "Enable" is selected for the Storage Cluster function. |
Selected: Notify Cleared |
|||
Connect Storage Cluster Controller |
Select whether to notify when communication with the paired storage system is recovered if the Storage Cluster controller has been specified. When notifying, select the notification method. This item is only displayed when "Enable" is selected for the Storage Cluster function. |
Selected: Notify Cleared |
Threshold of SDP usage can be specified with the [Modify Copy Parameters] function.
Threshold of copy table size usage can be specified with the [Modify Copy Table Size] function.
If free space of an ODX Buffer volume is insufficient, expand the volume capacity as required. Refer to the [Expand Volume], [Start RAID Migration], or [Expand Thin Provisioning Volume] function for details.
Operating Procedures
Click [Setup Event Notification] in [Action].
Specify whether to notify each event, and click the [Set] button.
→ A confirmation screen appears.
NoteEvent notifications can be reset to the default state. Click the [System Defaults] button to display the default state and click the [Set] button. For the settings, refer to "Initial Setting List".
When setting the REMCS recommended pattern, click the [REMCS Defaults] button to display the REMCS recommended pattern and click the [Set] button. For the settings, refer to "REMCS Recommended Setting List".
Click the [OK] button.
→ The event notification setting starts.
Click the [Done] button to return to the [Event/Dump] screen.
Initial Setting List
The initial setting of event notification is described below.
Setting based on Severity
Item | Notification method | |||||
---|---|---|---|---|---|---|
Host Sense Key Code Qualifier | SNMP Trap | syslog | REMCS | AIS Connect | ||
All Error Events |
Selected/Cleared |
Selected/Cleared |
Selected/Cleared |
Cleared |
Selected/Cleared |
Selected/Cleared |
All Warning Events |
Selected |
Selected |
Selected |
Cleared |
Cleared |
Selected |
All Informational Events |
- |
Selected/Cleared |
Selected/Cleared |
Cleared |
Cleared |
Selected/Cleared |
Individual Settings within Severity Level |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Selected: Notify
Cleared: Not notify
Selected/Cleared: Some events are notified and other events are not notified
-: Not applicable to notification
Event | Notification | Remarks | |
---|---|---|---|
Blink Fault LED at warning |
Enable |
- | |
Turn on Fault LED when redundant copy is completed |
Disable |
- | |
Display parts (except drive) with error status on LCD |
Enable |
This is displayed only for the ETERNUS DX900 S5 or the ETERNUS DX8900 S4. |
|
Display parts (except drive) with warning status on LCD |
Enable |
||
Display drives with error status on LCD |
Any Time |
Enable |
|
when HS<0 |
Disable |
||
Display drives with warning status on LCD |
Any Time |
Enable |
|
when HS<0 |
Disable |
[Error Severity Level], [Warning Level], and [Informational Level]
Level | Event | Notification method | ||||||
---|---|---|---|---|---|---|---|---|
Host Sense Key Code Qualifier | SNMP Trap | syslog | REMCS | AIS Connect | ||||
Error |
Parts Error |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
|
Drive Error |
Any Time |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
|
when HS<0 |
Cleared |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Drive Error of HDD Shield |
Any Time |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
|
when HS<0 |
Cleared |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Succeeded HDD Shield |
- |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
Temperature Error |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
End of battery life |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Rebuild/Copyback w/ redundant |
Selected |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
Rebuild/Copyback w/o redundant |
Any Time |
Selected |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
|
when HS<0 |
Cleared |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Redundant |
Any Time |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
|
when HS<0 |
Cleared |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Complete Redundant Copy |
Cleared |
Cleared |
Cleared |
Cleared |
Selected |
Selected |
||
Complete Redundant Copy of HDD Shield |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
Complete rebuild |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Bad data |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Pinned data |
Selected (*1) |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Not Ready |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Remote Path Error during Data Transfer |
Selected |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
Remote Path Error of no Data Transfer |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
REC Buffer Halt (Path Error) |
- |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
REC Buffer Halt (Overload) |
- |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
REC Buffer Halt (Other Error) |
- |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
Copy Session Error |
- |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
Thin Provisioning Pool Rate |
- |
Selected |
Selected |
Cleared |
- |
Cleared |
||
SED Network Error |
- |
Selected |
Selected |
Cleared |
Cleared |
Cleared |
||
NAS I/O Error |
- |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
NAS Snapshot Error |
- |
Selected |
Selected |
Cleared |
Cleared |
Cleared |
||
Extended System Volume Error |
- |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Disconnect Storage Cluster Controller |
- |
Selected |
Cleared |
Cleared |
Cleared |
Cleared |
||
Data Access Failed During RAID Group Redundancy Loss |
- |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
Warning |
Parts Warning |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
|
Drive Warning |
Any Time |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
|
when HS<0 |
Cleared |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Drive Warning of HDD Shield |
Any Time |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
|
when HS<0 |
Cleared |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Temperature Warning |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Battery life Warning |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
NAS I/O Warning |
- |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
NAS Connection Error |
- |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Out of NAS Capacity |
- |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
NAS Quota Limit Exceeded |
- |
Selected |
Selected |
Cleared |
Cleared (fixed) |
Cleared |
||
Extended System Volume Warning |
- |
Selected |
Selected |
Cleared |
- |
- |
||
RAID Group Redundancy Lost or Recovered |
- |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
Informational |
Recovery module |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
|
Temperature restoration |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
User login/logout |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Operated RAID Group |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Added/Released Hot Spare |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Operated Volume |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Power off/on Apply Firmware |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
SDP Usage Rate Over Lv1 |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
SDP Usage Rate Over Lv2 |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
SDP Usage Rate Over Lv3 |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Copy Table Size Usage Rate Over |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Trial copy license expired |
- |
Selected |
Selected |
Cleared |
- |
Cleared |
||
Remote Path Recovery |
- |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
No Free Space on ODX Buffer Volume |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
SED Network Error Recovered |
- |
Selected |
Selected |
Cleared |
- |
- |
||
FC CA Port Link Status Changed |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
iSCSI CA Port Link Status Changed |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Host Login Over |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
NAS Connection Status |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Out of NAS Capacity |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Out of NAS File Management Domain |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Succeed NAS Snapshot |
- |
Selected |
Cleared |
Cleared |
- |
Cleared |
||
Fall below NAS Quota Limit |
- |
Selected |
Cleared |
Cleared |
- |
Cleared |
||
NAS CPU Warning |
- |
Cleared |
Cleared |
Cleared |
- |
- |
||
NAS CPU Recovered |
- |
Cleared |
Cleared |
Cleared |
- |
- |
||
Extended System Volume Recovered |
- |
Selected |
Selected |
Cleared |
- |
- |
||
Multipath Status |
- |
Cleared |
Cleared |
Cleared |
- |
- |
||
Automatic Change Storage Cluster Active/Standby State |
- |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
Manual Change Storage Cluster Active/Standby State |
- |
Selected |
Cleared |
Cleared |
Cleared |
Cleared |
||
Connect Storage Cluster Controller |
- |
Selected |
Cleared |
Cleared |
Cleared |
Cleared |
Selected: Notify
Cleared: Not notify
Selected (fixed): Always notify (This setting cannot be changed with this function.)
-: Not applicable to notification
*1 | : | Host Sense Key Code Qualifier is not notified when pinned data disappears. |
REMCS Recommended Setting List
The REMCS recommended setting of event notification is described below. For the notification methods indicated with "*", notification setting has been changed from the system default.
Setting based on Severity
Item | Notification method | |||||
---|---|---|---|---|---|---|
Host Sense Key Code Qualifier | SNMP Trap | syslog | REMCS | AIS Connect | ||
All Error Events |
Selected/Cleared |
Selected/Cleared |
Selected/Cleared |
Cleared |
Selected/Cleared |
Selected/Cleared |
All Warning Events |
Cleared * |
Cleared * |
Cleared * |
Cleared |
Cleared |
Cleared * |
All Informational Events |
- |
Selected/Cleared |
Selected/Cleared |
Cleared |
Cleared |
Selected/Cleared |
Individual Settings within Severity Level |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Selected: Notify
Cleared: Not notify
Selected/Cleared: Some events are notified and other events are not notified
-: Not applicable to notification
Event | Notification | Remarks | |
---|---|---|---|
Blink Fault LED at warning |
Disable * |
- | |
Turn on Fault LED when redundant copy is completed |
Disable |
- | |
Display parts (except drive) with error status on LCD |
Enable |
This is displayed only for the ETERNUS DX900 S5 or the ETERNUS DX8900 S4. |
|
Display parts (except drive) with warning status on LCD |
Disable * |
||
Display drives with error status on LCD |
Any Time |
Disable * |
|
when HS<0 |
Enable * |
||
Display drives with warning status on LCD |
Any Time |
Disable * |
|
when HS<0 |
Disable |
[Error Severity Level], [Warning Level], and [Informational Level]
Level | Event | Notification method | ||||||
---|---|---|---|---|---|---|---|---|
Host Sense Key Code Qualifier | SNMP Trap | syslog | REMCS | AIS Connect | ||||
Error |
Parts Error |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
|
Drive Error |
Any Time |
Cleared * |
Cleared * |
Cleared * |
Cleared |
Selected (fixed) |
Cleared * |
|
when HS<0 |
Cleared |
Selected * |
Selected * |
Cleared |
- |
Selected * |
||
Drive Error of HDD Shield |
Any Time |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
|
when HS<0 |
Cleared |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Succeeded HDD Shield |
- |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
Temperature Error |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
End of battery life |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Rebuild/Copyback w/ redundant |
Cleared * |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
Rebuild/Copyback w/o redundant |
Any Time |
Cleared * |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
|
when HS<0 |
Selected * |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Redundant |
Any Time |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
|
when HS<0 |
Cleared |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Complete Redundant Copy |
Cleared |
Cleared |
Cleared |
Cleared |
Selected |
Selected |
||
Complete Redundant Copy of HDD Shield |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
Complete rebuild |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Bad data |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Pinned data |
Selected (*1) |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Not Ready |
Selected |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Remote Path Error during Data Transfer |
Selected |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
Remote Path Error of no Data Transfer |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
REC Buffer Halt (Path Error) |
- |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
REC Buffer Halt (Overload) |
- |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
REC Buffer Halt (Other Error) |
- |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
Copy Session Error |
- |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
Thin Provisioning Pool Rate |
- |
Selected |
Selected |
Cleared |
- |
Cleared |
||
SED Network Error |
- |
Selected |
Selected |
Cleared |
Cleared |
Cleared |
||
NAS I/O Error |
- |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
NAS Snapshot Error |
- |
Selected |
Selected |
Cleared |
Cleared |
Cleared |
||
Extended System Volume Error |
- |
Selected |
Selected |
Cleared |
Selected (fixed) |
Selected |
||
Disconnect Storage Cluster Controller |
- |
Selected |
Cleared |
Cleared |
Cleared |
Cleared |
||
Data Access Failed During RAID Group Redundancy Loss |
- |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
Warning |
Parts Warning |
Cleared * |
Cleared * |
Cleared * |
Cleared |
Selected (fixed) |
Cleared * |
|
Drive Warning |
Any Time |
Cleared * |
Cleared * |
Cleared * |
Cleared |
Selected (fixed) |
Cleared * |
|
when HS<0 |
Cleared |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Drive Warning of HDD Shield |
Any Time |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
|
when HS<0 |
Cleared |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Temperature Warning |
Cleared * |
Cleared * |
Cleared * |
Cleared |
Selected (fixed) |
Cleared * |
||
Battery life Warning |
Cleared * |
Cleared * |
Cleared * |
Cleared |
Selected (fixed) |
Cleared * |
||
NAS I/O Warning |
- |
Cleared * |
Cleared * |
Cleared |
Selected (fixed) |
Cleared * |
||
NAS Connection Error |
- |
Cleared * |
Cleared * |
Cleared |
Selected (fixed) |
Cleared * |
||
Out of NAS Capacity |
- |
Cleared * |
Cleared * |
Cleared |
Selected (fixed) |
Cleared * |
||
NAS Quota Limit Exceeded |
- |
Selected |
Cleared * |
Cleared |
Cleared (fixed) |
Cleared |
||
Extended System Volume Warning |
- |
Selected |
Selected |
Cleared |
- |
- |
||
RAID Group Redundancy Lost or Recovered |
- |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
Informational |
Recovery module |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
|
Temperature restoration |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
User login/logout |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Operated RAID Group |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Added/Released Hot Spare |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Operated Volume |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Power off/on Apply Firmware |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
SDP Usage Rate Over Lv1 |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
SDP Usage Rate Over Lv2 |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
SDP Usage Rate Over Lv3 |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Copy Table Size Usage Rate Over |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Trial copy license expired |
- |
Selected |
Selected |
Cleared |
- |
Cleared |
||
Remote Path Recovery |
- |
Cleared |
Cleared |
Cleared |
Cleared |
Cleared |
||
No Free Space on ODX Buffer Volume |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
SED Network Error Recovered |
- |
Selected |
Selected |
Cleared |
- |
- |
||
FC CA Port Link Status Changed |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
iSCSI CA Port Link Status Changed |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Host Login Over |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
NAS Connection Status |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Out of NAS Capacity |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Out of NAS File Management Domain |
- |
Cleared |
Cleared |
Cleared |
- |
Cleared |
||
Succeed NAS Snapshot |
- |
Selected |
Cleared |
Cleared |
- |
Cleared |
||
Fall below NAS Quota Limit |
- |
Selected |
Cleared |
Cleared |
- |
Cleared |
||
NAS CPU Warning |
- |
Cleared |
Cleared |
Cleared |
- |
- |
||
NAS CPU Recovered |
- |
Cleared |
Cleared |
Cleared |
- |
- |
||
Extended System Volume Recovered |
- |
Selected |
Selected |
Cleared |
- |
- |
||
Multipath Status |
- |
Cleared |
Cleared |
Cleared |
- |
- |
||
Automatic Change Storage Cluster Active/Standby State |
- |
Selected |
Selected |
Cleared |
Selected |
Selected |
||
Manual Change Storage Cluster Active/Standby State |
- |
Selected |
Cleared |
Cleared |
Cleared |
Cleared |
||
Connect Storage Cluster Controller |
- |
Selected |
Cleared |
Cleared |
Cleared |
Cleared |
Selected: Notify
Cleared: Not notify
Selected (fixed): Always notify (This setting cannot be changed with this function.)
-: Not applicable to notification
*1 | : | Host Sense Key Code Qualifier is not notified when pinned data disappears. |