Add Channel Adapter

Overview

This function adds a Channel Adapter (CA) without stopping the storage system.

After installing a CA for the storage system, activate it via Web GUI.

Caution
  • Perform the start maintenance operation by using the [Start/End Maintenance] function before adding a CA. If the operation has not been performed, addition cannot be started.

  • Be sure to use authorized additional parts. If parts other than the additional parts are used, operation is not guaranteed.

  • Only one CA can be added at a time.

  • This function cannot be used under the following conditions:
    • The status of the CA that is to be added or the CM to which the target CA belongs is not normal

    • The maximum number of CAs specified for the model have already been installed
      • For the ETERNUS DX600 S6/DX900 S6, and the ETERNUS DX8900 S6: Up to four CAs per CM

      • For the ETERNUS DX8100 S6: Up to two CAs per CM

    • No CA is added to the expansion slot

Display Contents

The following screens are displayed by the wizard.

[Start] Screen

A message that indicates the start of CA expansion appears.

[Workflow] Screen

The procedure to install a CA is displayed. Install a CA according to the displayed procedure.

[Get Status] Screen

The progress rate of status confirmation for the added CA is displayed.

Item Description

Progress

The progress rate (0 to 100 %) of the status check is displayed.

[Select CA] Screen

Select the added CA.

Item Description

Radio button

Select the added CA.

Enclosure

The CE number is displayed to determine the CM that is installed with a CA.

This is displayed for the ETERNUS DX900 S6 or the ETERNUS DX8900 S6.

CE#n

CM

The CM number to which the CA belongs is displayed.

CM#n

CA

The CA number is displayed.

CA#n

Type

The CA type is displayed.

[Status Check] Screen

The progress rate for the activation processing of the added CA is displayed.

Status Check

Item Description

Enclosure

The CE number is displayed to determine the CM that is installed with the added CA.

This is displayed for the ETERNUS DX900 S6 or the ETERNUS DX8900 S6.

CE#n

CM

The CM number to which the CA has been added is displayed.

CM#n

CA

The added CA number is displayed.

CA#n

Progress

The progress rate (0 to 100 %) of the status check is displayed.

Status

The CA status is displayed.

[Finish] Screen

A message that indicates the CA is added successfully is displayed.

Operating Procedures

  1. Click [Add Channel Adapter] in [Action].

    → The [Start] Screen appears.

  2. Click the [Next >>] button.

    → The [Workflow] Screen appears.

  3. Add the CA according to the displayed procedure and click the [Next >>] button.

    → The status check of the added CA starts, and the [Get Status] Screen appears. When the status check is complete, the [Select CA] Screen appears.

  4. Select the added CA, and click the [Next >>] button.

    → The [Status Check] Screen appears. When the status check is complete, the [Finish] Screen appears.

  5. Click the [Done] button to return to the [Channel Adapter] screen.