Force Disable Module

Overview

When there is a component which cannot be isolated from the storage system in a normal way, this function forces the component to be isolated from the storage system (called "force disable" hereinafter).

This function is used when preparing a component to be removed from the storage system using the hot maintenance or hot preventive maintenance functions, and the status of the component cannot be changed to normal. If the component is installed in the storage system, this function can be performed, irrespective of the status.

Availability of Force Disable (For the ETERNUS DX60 S5, the ETERNUS DX100 S5/DX200 S5, and the ETERNUS AF150 S3/AF250 S3) (Force disable is possible: , Force disable is not possible or not applicable: -)

Component Force Disable

ETERNUS DX60 S5

ETERNUS DX100 S5/DX200 S5

ETERNUS AF150 S3/AF250 S3

Controller Enclosure (CE) - - -
  Controller Module (CM)
  Memory - - -
BBU - - -
Bootup and Utility Device (BUD) - -
(*1)
32G FC-CA -
  SFP+ -
16G FC-CA
(*2)
  SFP+
8G FC-CA
(*2)
- -
  SFP+
- -
10G iSCSI-CA -
  SFP+ -
10G Base-T iSCSI
(*2)
  Port
1G iSCSI-CA
(*2)
-
  Port
-

10G NAS-CA

-
-
 

SFP+

-
-

1G NAS-CA

-
-
 

Port

-
-
12G SAS-CA
(*2)
-
  SFP
-
Mid Plane (MP) - - -

Power Supply Unit (PSU)

Drive
Power Cord - - -
Panel - - -
Drive Enclosure (DE) - - -
 

Power Supply Unit (PSU)

Drive
Panel - - -
I/O Module (IOM)
Fan Expander Module (FEM) -
(*3)
-
Power Cord - - -
SAS Cable
*1  :  Force disable is available only for the ETERNUS AF250 S3.
*2  :  To perform a force disable of CA, use the force disable function for the CM that includes the CA.
*3  :  A component that is installed in high density DEs.

Availability of Force Disable (For the ETERNUS DX500 S5/DX600 S5 and the ETERNUS AF650 S3) (Force disable is possible: , Force disable is not possible or not applicable: -)

Component Force Disable Module

ETERNUS DX500 S5/DX600 S5

ETERNUS AF650 S3

Controller Enclosure (CE) - -
  Controller Module (CM)
  Memory - -
BUD
FAN Unit - -
PCIe SW - -
IOC Port - -
EXP Port - -
32G FC-CA
  SFP+
16G FC-CA
  SFP+
10G iSCSI-CA
  SFP+
1G iSCSI-CA
-
  Port
-
iSCSI-RA
  Port

10G NAS-CA

-
 

SFP+

-

1G NAS-CA

-
 

Port

-
CBP - -
PCIe Flash Module (PFM)
-
Controller Enclosure Power Supply Unit (CPSU)
Operation Panel (OPNL) - -
Battery Unit - -
  Battery Control Unit (BCU)
Battery Unit (BTU)

Drive

Drive Enclosure (DE) - -
 

Power Supply Unit (PSU)

Drive
Panel - -
I/O Module (IOM)
Fan Expander Module (FEM)
(*1)
-
Power Cord - -
SAS Cable
*1  :  A component that is installed in high density DEs.

Availability of Force Disable (For the ETERNUS DX8100 S4) (Force disable is possible: , Force disable is not possible or not applicable: -)

Component Force Disable Module
Controller Enclosure (CE) -
  Controller Module (CM)
  Memory -
BUD
FAN Unit -
PCIe SW -
IOC Port -
EXP Port -
32G FC-CA
  SFP+
16G FC-CA
  SFP+
10G iSCSI-CA
  SFP+
1G iSCSI-CA
  Port
iSCSI-RA
  Port
CEMP -
CEMP-D -
Controller Enclosure Power Supply Unit (CPSU)
Operation Panel (OPNL) -
Battery Unit -
  Battery Control Unit (BCU)
Battery Unit (BTU)
Power Cord -
Drive
(*1)
Drive Enclosure (DE) -
 

Power Supply Unit (PSU)

Drive
Panel -
I/O Module (IOM)
Power Cord -
SAS Cable
*1  :  A component that is installed in the CE of the ETERNUS DX8100 S4.

Availability of Force Disable (For the ETERNUS DX900 S5 or the ETERNUS DX8900 S4) (Force disable is possible: , Force disable is not possible or not applicable: -)

Component Force Disable Module
Controller Enclosure (CE) -
  Controller Module (CM)
  Memory -
BUD
FAN Unit -
PCIe SW -
IOC Port -
BE Port -
FRT Port -
SVC Port -
32G FC-CA
  SFP+
16G FC-CA
  SFP+
10G iSCSI-CA
  SFP+
1G iSCSI-CA
  Port
iSCSI-RA
  Port
CEMP -
CEMP-D -
PCIe Flash Module (PFM)
Controller Enclosure Power Supply Unit (CPSU)
Operation Panel (OPNL) -
Battery Unit -
  Battery Control Unit (BCU)
Battery Unit (BTU)
Power Cord -
Drive
Frontend Enclosure (FE) -
  Frontend Enclosure Power Supply Unit (FE PSU)
Frontend Router (FRT)
  QSFP+
Service Controller (SVC)
  Port -
Management Cable
FE MP -
FE MP BRG -
Operation Panel (OPNL)
FAN Unit (FANU)
FPO-SW -
Drive Enclosure (DE) -
 

Power Supply Unit (PSU)

Drive
Panel -
I/O Module (IOM)
Fan Expander Module (FEM)
(*1)
Power Cord -
SAS Cable
*1  :  A component that is installed in high density DEs.
Caution
Note
  • To perform a force disable of the CA for the ETERNUS DX60 S5 with a CM-FC (CM with direct mount CA), use the force disable function for the CM that includes the CA.

User Privileges

Availability of Executions in the Default Role

Default role Availability of executions
Monitor  
Admin  
StorageAdmin  
AccountAdmin  
SecurityAdmin  
Maintainer

Refer to "User Roles and Policies" for details on the policies and roles.

Display Contents

[Test Connection] Screen

This screen is displayed when the Master CM is affected by the force disable.

Follow the displayed procedure to confirm that the new Master CM is connected to a LAN.

Function Button

Button Description

[Test Connection]

Click this button after confirming that the new Master CM is connected to a LAN.

The connection status of the new Master CM and the LAN is checked.

[Test Connection Result] Screen

This screen is displayed when the Master CM is affected by the force disable.

The connection status check result of the new Master CM and the LAN is displayed.

Function Button

Button Description

[Test Connection]

If connection has failed, reconfirm the new Master CM is connected to a LAN, and click this button.

The connection status of the new Master CM and the LAN is checked again.

[Resume Processing]

Click this button when connection was successful.

Isolation of the CM starts.

Operating Procedures

  1. Select the component to perform the force disable on, and click [Force Disable] in [Action].

    → A confirmation screen appears.

    Caution
    • When there is a component which can be affected by force disable, a message to that effect is displayed. Check the component which might be affected.

  2. Click the [OK] button.

    → The operations to be started and the displayed screen vary depending on the conditions as follows.

    • When the Master CM can be affected by the force disable

      → The Master CM is switched, and the [Test Connection] Screen appears. Proceed to Step 3.

    • When the Master CM cannot be affected by the force disable

      → Isolation of the target component starts. Proceed to Step 6.

  3. Follow the displayed procedure to confirm that the new Master CM is connected to a LAN.

  4. After confirming the connection, click the [Test Connection] button.

    → The [Test Connection Result] Screen appears.

  5. Confirm the connection status check result, and click the [Resume Processing] button.

    → Isolation of the target component starts.

    Caution
    • If the connection of the new Master CM and the LAN fails, check the connection status again and return to Step 4.

  6. Click the [Done] button to return to the screen when the target component was selected in Step 1.

    Note
    • When forcibly disabling a NAS-CA or a NAS-CA port, the process may take a maximum of 5 minutes to complete. Click the [Done] button and wait for the process to complete.