Component
Overview
This function can perform Status Display and maintenance for each part installed on the storage system.
Display Function List
Category | Function | Description | ||
---|---|---|---|---|
(Storage System Name) | Storage | The status of the entire storage system is displayed. | ||
Controller Enclosure | Controller Enclosure | The Controller Enclosure (CE) status is displayed. | ||
Controller Module | Controller Module | The controller (CM) status is displayed. | ||
Performance | Performance (CM) | The controller (CM) performance information is displayed. | ||
Channel Adapter | Channel Adapter | The Channel Adapter (CA) status is displayed. | ||
Performance | Performance (CA) | The Channel Adapter (CA) performance information is displayed. | ||
Login Host | Login Host | The hosts that are currently logged in to the port is displayed. | ||
PCIe Flash Module | PCIe Flash Module | The PCIe Flash Module (PFM) status is displayed. | ||
Performance | Performance (PCIe Flash Module) | The PCIe Flash Module (PFM) performance information is displayed. | ||
Bootup and Utility Device | Bootup and Utility Device | The BUD status list is displayed. [DX900 S5/DX8100 S4/DX8900 S4] |
||
Power Supply Unit | Power Supply Unit (CE) | The status of the power supply unit for the controller is displayed. | ||
Battery (BBU) | Battery (BBU) | The battery (BBU) status is displayed. [DX60 S5/DX100 S5/DX200 S5] |
||
Battery (BTU/BCU) | Battery (BTU/BCU) | The battery (BTU/BCU) status is displayed. | ||
Frontend Enclosure | Frontend Enclosure | The Frontend Enclosure (FE) information is displayed. [DX900 S5/DX8900 S4] | ||
Frontend Router | Frontend Router | The Frontend Router (FRT) information is displayed. [DX900 S5/DX8900 S4] | ||
Service Controller | Service Controller | The Service Controller (SVC) information is displayed. [DX900 S5/DX8900 S4] | ||
Power Supply Unit (FE) | Power Supply Unit (FE) | The information of the Power Supply Unit (PSU) for FE is displayed. [DX900 S5/DX8900 S4] | ||
FAN Unit | FAN Unit | The FAN Unit information is displayed. [DX900 S5/DX8900 S4] | ||
Operation Panel | Operation Panel | The Operation Panel information is displayed. [DX900 S5/DX8900 S4] | ||
Drive Enclosure | Drive Enclosure | The Drive Enclosure (DE) status is displayed. | ||
I/O Module | I/O Module | The I/O Module status is displayed. | ||
Error Statistics | Port Error Statistics | The port error information is displayed. | ||
Power Supply Unit | Power Supply Unit (DE) | The status of the power supply unit for the Drive Enclosure is displayed. | ||
Fan Expander Module | Fan Expander Module | The status of the Fan Expander Module for the Drive Enclosure is displayed. | ||
Drives | Drives | The drive status is displayed. | ||
Performance | Performance (Drives) | The drive performance information is displayed. | ||
Error Statistics | Drive Error Statistics | The drive error information is displayed. |
Action List
Action | Function | Description |
---|---|---|
Start/End Maintenance | Start/End Maintenance | Switch the storage system to the maintenance operation mode. |
Model Upgrade | Model Upgrade | Upgrade the storage system from a low-end model to a high-end model. |
Turn on locator beacon | Turn on Locator Beacon/Turn off Locator Beacon | Turn on/off the LED to indicate the location of the storage system. |
Turn off locator beacon | ||
Preventive Maintenance | Hot Preventive Maintenance | Perform hot preventive maintenance for selected parts. |
Force Enable | Force Enable Module | Forcibly enable selected parts. |
Force Disable | Force Disable Module | Forcibly disable selected parts. |
Sanitize Drive |
Start a data sanitization process for drives. |
|
Add Controller Enclosure | Add Controller Enclosure | Add CEs. [DX900 S5/DX8900 S4] |
Add Controller Module | Add Controller Module | Add controllers. |
Add Memory | Add Memory | Add memory to the controller. |
Export Performance Info | Export Performance Information | Export the performance information. |
Add Channel Adapter | Add Channel Adapter | Add CAs. |
Add Channel Adapter Port | Add Channel Adapter Port | Add CA ports. |
Remove Channel Adapter | Remove Channel Adapter | Remove CAs. |
Add PCIe Flash Module | Add PCIe Flash Module | Add PFMs. |
Remove PCIe Flash Module | Remove PCIe Flash Module | Remove PFMs. |
Add Drive Enclosure | Add Drive Enclosure | Add DEs. |
Remove Drive Enclosure | Remove Drive Enclosure | Remove DEs. |
Recover NAS System Volume | Recover NAS System Volume | Recover the NAS system volumes (RootFS) that are used by the NAS Engine. |
Assign Global HS | Assign Global Hot Spare | Assign Global Hot Spares. |
Release Global HS | Release Global Hot Spare | Release Global Hot Spares. |
Assign Dedicated HS | Assign Dedicated Hot Spare | Assign Dedicated Hot Spares. |
Release Dedicated HS | Release Dedicated Hot Spare | Release Dedicated Hot Spares. |
Remove Disk Drive | Remove Disk Drive | Remove disk drives. |
Start Diagnosis | Start Disk Diagnosis | Start disk diagnosis. |
Clear All Error | Clear Drive Error Statistics (All Drives) | Clear error statistics of all drives. |
Clear Error | Clear Drive Error Statistics (Selected Drives) | Clear error statistics of selected drives. |