Remove Drive Enclosure

Overview

This function removes a Drive Enclosure (DE) without stopping the storage system.

After the target DEs are isolated, remove these DEs from the storage system.

Caution
  • Perform the start maintenance operation by using the [Start/End Maintenance] function before the removing task. If the operation has not been performed, the removal cannot be started.

  • When DE hot removal is performed, multiple DEs can be removed with a single operation.

    Note that multiple DEs can only be removed when they are allocated to the same SAS cascade configuration (*1). Multiple DEs that are allocated to different SAS cascade configurations cannot be removed. Refer to "DEs on the Same SAS Cascade" for details.

    *1  :  "SAS cascade" refers to DEs that are attached to one DI port.
  • The DEs that are sequentially located from the terminal DE in each SAS cascade configuration can be removed.

  • 2.5" DEs, 3.5" DEs, and 3.5" high density DEs can be removed at the same time.

  • This function cannot be used under the following conditions:
    • Drives in the DE, which is to be removed, are registered in the RAID groups, the hot spares, the Thin Provisioning Pools, the Flexible Tier Pools, the REC Disk Buffers, or the Extreme Cache Pools.

    • The status of the DE below is "Undefined"
      • For the ETERNUS DX60 S5: DE#01

      • For the ETERNUS DX100 S5/DX200 S5: DE#01

      • For the ETERNUS DX500 S5: DE#01, DE#10, DE#20, and DE#30

      • For the ETERNUS DX600 S5: DE#01, DE#10, DE#20, and DE#30

      • For the ETERNUS DX900 S5: DE#x1, DE#x4, DE#x8, and DE#xC (x: 0 - 1)

      • For the ETERNUS DX8100 S4: DE#10

      • For the ETERNUS DX8900 S4: DE#x1, DE#x4, DE#x8, and DE#xC (x: 0 - B)

      • For the ETERNUS AF250 S3: DE#01

      • For the ETERNUS AF650 S3: DE#01, DE#10, DE#20, and DE#30

DEs on the Same SAS Cascade

The DEs that are allocated to the same SAS cascade configuration are as follows:

  • For the ETERNUS DX60 S5

    DE#01, DE#02, and DE#03, which are connected to DI Port No.0.

  • For the ETERNUS DX100 S5/DX200 S5

    DE#01, DE#02, DE#03, DE#04, DE#05, DE#06, DE#07, DE#08, DE#09, and DE#0A, which are connected to DI Port No.0.

  • For the ETERNUS DX500 S5

    CE, DE#01, DE#02, DE#03, DE#04, and DE#05, which are connected to DI Port No.0.

    DE#y0, DE#y1, DE#y2, DE#y3, DE#y4, and DE#y5, which are connected to DI Port No.x.

    ETERNUS DX500 S5: x = 1 - 3, y = 1 - 3

    (Example) DE#10, DE#11, DE#12, DE#13, DE#14, and DE#15, which are connected to DI Port No.1.

  • For the ETERNUS DX600 S5

    CE, DE#01, DE#02, DE#03, DE#04, DE#05, DE#06, DE#07, DE#08, DE#09, and DE#0A, which are connected to DI Port No.0.

    DE#y0, DE#y1, DE#y2, DE#y3, DE#y4, DE#y5, DE#y6, DE#y7, DE#y8, DE#y9, and DE#yA, which are connected to DI Port No.x.

    ETERNUS DX600 S5: x = 1 - 3, y = 1 - 3

    (Example) DE#10, DE#11, DE#12, DE#13, DE#14, DE#15, DE#16, DE#17, DE#18, DE#19, and DE#1A, which are connected to DI Port No.1.

  • For the ETERNUS DX900 S5

    Two CEs can be installed in the ETERNUS DX900 S5.

    DE#x1, DE#x2, and DE#x3 that are connected to CE#x/DI Port#0 (x: 0, 1, C, D, E, or F)

    DE#x4, DE#x5, DE#x6, and DE#x7 that are connected to CE#x/DI Port#1 (x: 0, 1, C, D, E, or F)

    DE#x8, DE#x9, DE#xA, and DE#xB that are connected to CE#x/DI Port#2 (x: 0, 1, C, D, E, or F)

    DE#xC, DE#xD, DE#xE, and DE#xF that are connected to CE#x/DI Port#3 (x: 0, 1, C, D, E, or F)

    (Example) DE#01, DE#02, and DE#03 that are connected to CE#0/DI Port#0 are on the same SAS cascade.

  • For the ETERNUS DX8100 S4

    DE#01, which is connected to DI Port No.0.

  • For the ETERNUS DX8900 S4

    Multiple CEs can be installed in the ETERNUS DX8900 S4.

    DE#x1, DE#x2, and DE#x3 that are connected to CE#x/DI Port#0 (x:0 - B)

    DE#x4, DE#x5, DE#x6, and DE#x7 that are connected to CE#x/DI Port#1 (x:0 - B)

    DE#x8, DE#x9, DE#xA, and DE#xB that are connected to CE#x/DI Port#2 (x:0 - B)

    DE#xC, DE#xD, DE#xE, and DE#xF that are connected to CE#x/DI Port#3 (x:0 - B)

    (Example) DE#01, DE#02, and DE#03 that are connected to CE#0/DI Port#0 are on the same SAS cascade.

  • For the ETERNUS AF250 S3

    DE#01, DE#02, DE#03, DE#04, DE#05, DE#06, DE#07, DE#08, DE#09, DE#0A, which are connected to DI Port No.0.

  • For the ETERNUS AF650 S3

    CE, DE#01, DE#02, DE#03, DE#04, DE#05, DE#06, DE#07, DE#08, DE#09, and DE#0A, which are connected to DI Port No.0.

    DE#y0, DE#y1, DE#y2, DE#y3, DE#y4, DE#y5, DE#y6, DE#y7, DE#y8, DE#y9, and DE#yA, which are connected to DI Port No.x.

    ETERNUS AF650 S3: x = 1 - 3, y = 1 - 3

User Privileges

Availability of Executions in the Default Role

Default role Availability of executions
Monitor  
Admin  
StorageAdmin  
AccountAdmin  
SecurityAdmin  
Maintainer

Refer to "User Roles and Policies" for details on the policies and roles.

Display Contents

The following screens are displayed by the wizard.

[Start] Screen

The DE that is to be removed is displayed.

Target Drive Enclosure

Item Description

Enclosure

The DE that is to be removed is displayed.

DE#xx

xx: DE number

Type

The DE type that is to be removed is displayed.

  • For 2.5" DEs, "2.5" 24DE" is displayed.

  • For 3.5" DEs, "3.5" 12DE" is displayed.

  • For 3.5" high density DEs, "3.5" 60DE" is displayed.

If DEs are removed while the storage system is running, a list of the components that will be disabled after the DEs are removed is displayed.

Disable Target Parts

Item Description

Enclosure

The DE in which the components that are to be disabled are installed is displayed.

DE#xx

xx: DE number

Type

The type of the DE in which the components that are to be disabled are installed is displayed.

  • For 2.5" DEs, "2.5" 24DE" is displayed.

  • For 3.5" DEs, "3.5" 12DE" is displayed.

  • For 3.5" high density DEs, "3.5" 60DE" is displayed.

Parts

The components that are to be disabled are displayed.

"FEM#1" is displayed only for 3.5" high density DEs.

IOM#1

FEM#1

Status

The status of the components that are to be disabled is displayed.

Refer to "Component Status" for details.

[Remove DE from configuration] Screen

The DEs that are to be removed are displayed as the target drive enclosures. When multiple DEs are removed, the items are separated with a "," (comma) and displayed.

The status of the components in the DE and the progress rate of isolating the DE are displayed in "Status Check".

Status Check

Item Description

Enclosure

The DEs in the target SAS cascade configuration are displayed.

DE#xx

xx: DE number

Type

The DE type is displayed.

  • For 2.5" DEs, "2.5" 24DE" is displayed.

  • For 3.5" DEs, "3.5" 12DE" is displayed.

  • For 3.5" high density DEs, "3.5" 60DE" is displayed.

Parts

The components in the DE that is to be removed are displayed.

IOM#x

FEM#y

PSU#z

x: IOM number

y: FEM number

z: PSU number

Progress

The progress rate (0 to 100 %) of isolating the component is displayed.

Status

The component status is displayed.

[Enable IOM#1] Screen

The DEs that are to be removed are displayed as the target drive enclosures. When multiple DEs are removed, the items are separated with a "," (comma) and displayed.

The activation progress of the IOM#1 with the SAS cable is displayed in "Status Check".

Status Check

Item Description

Enclosure

The DEs that remain in the target SAS cascade configuration are displayed.

DE#xx

xx: DE number

Type

The DE type is displayed.

  • For 2.5" DEs, "2.5" 24DE" is displayed.

  • For 3.5" DEs, "3.5" 12DE" is displayed.

  • For 3.5" high density DEs, "3.5" 60DE" is displayed.

Parts

The components in the DE that is to be removed are displayed.

IOM#x

FEM#y

x: IOM number

y: FEM number

Progress

The component activation progress rate (0 to 100 %) is displayed.

Status

The component status is displayed.

[Unmount DE] Screen

The DE removal procedure is displayed on this screen. Remove the DE according to the displayed procedure.

Item Description

Target Drive Enclosure

The DE that is to be removed is displayed.

DE#xx

xx: DE number

Type

The DE type is displayed.

  • For 2.5" DEs, "2.5" 24DE" is displayed.

  • For 3.5" DEs, "3.5" 12DE" is displayed.

  • For 3.5" high density DEs, "3.5" 60DE" is displayed.

[Finish] Screen

A message that indicates the DE is removed successfully is displayed.

Operating Procedures

  1. Select DEs that are to be removed (multiple selections can be made), and click [Remove Drive Enclosure] in [Action].

    → The [Start] Screen appears.

  2. Check the DE to be removed, and click the [Next >>] button.

    →The DEs in the same SAS cascade configuration as the target DEs are isolated. The [Remove DE from configuration] Screen appears.

        When the DE isolation is complete, the [Detach Cable] screen appears.

  3. Disconnect the SAS cables according to the displayed work procedure and click the [Next >>] button.

    The screen that is displayed depends on the DE status in the target SAS cascade configuration.

    • When there are DEs that remain in the SAS cascade configuration after the target DEs are removed

      →The [Connect Cable] screen appears. Proceed to Step 4.

    • When all of the removal processes for the relevant DEs are complete

      → The [Unmount DE] Screen appears. Proceed to Step 5.

  4. Connect the SAS cables according to the displayed procedure and click the [Next >>] button.

    → The activation of IOM#1, which was not removed, starts. The [Enable IOM#1] Screen is displayed.

        After IOM#1 is activated, the [Unmount DE] Screen appears.

  5. Remove the relevant DE from the storage system according to the displayed workflow and click the [Next >>] button.

    → The [Finish] Screen appears.

  6. Click the [Done] button to return to the [Drive Enclosure] screen.