Frontend Enclosure
Overview
This function displays the Frontend Enclosure (FE) information.
This is displayed for the ETERNUS DX900 S5 or the ETERNUS DX8900 S4.
User Privileges
Availability of Executions in the Default Role
Default role | Availability of executions |
---|---|
Monitor | |
Admin | |
StorageAdmin | |
AccountAdmin | |
SecurityAdmin | |
Maintainer |
Refer to "User Roles and Policies" for details on the policies and roles.
Display Contents
In this screen, FE information is displayed.
[Summary] Tab
FE Information
Item | Description | |
---|---|---|
Location |
The installation location of the thermal sensor is displayed. Intake Temp Internal Temp |
|
Status |
The thermal sensor status is displayed. Normal Warning Maintenance Error Unknown |
|
Error Code |
The error code of the thermal sensor is displayed. |
|
Sensor 1 |
Intake Temp |
The temperature of SVC#0 is displayed. If the thermal information is not available due to problem such as a sensor failure, a "-" (hyphen) is displayed. C: Celsius temperature F: Fahrenheit temperature |
Internal Temp |
A "-" (hyphen) is usually displayed. |
|
Sensor 2 |
Intake Temp |
The temperature of SVC#1 is displayed. If the thermal information is not available due to problem such as a sensor failure, a "-" (hyphen) is displayed. C: Celsius temperature F: Fahrenheit temperature |
Internal Temp |
A "-" (hyphen) is usually displayed. |
[Front View] Tab
FE Front View
Item | Description |
---|---|
(Storage system image) |
The front view of the FE that is installed in the storage system is displayed. The Service Controller (SVC) status and the FAN Unit (FANU) status are indicated by icons. Click the SVC number to display the [Service Controller Detail] screen. Click the FANU number to display the [FAN Unit Detail] screen. Refer to "Component Status" for details. |
FE Internal Parts Information
Item | Description |
---|---|
Parts |
The SVC number and the FANU number are displayed. Click the SVC number to display the [Service Controller Detail] screen. Click the FANU number to display the [FAN Unit Detail] screen. SVC#x FANU#y x: SVC number y: FANU number |
Status |
The status of each component is displayed. Refer to "Component Status" for details. |
Status Code |
The status code of each component is displayed. |
Error Code |
The error code of each component is displayed. |
[Rear View] Tab
FE Rear View
Item | Description |
---|---|
(Storage system image) |
The rear view of the FE that is installed in the storage system is displayed. The Frontend Router (FRT) status and the FE Power Supply Unit (FPSU) status are indicated by icons. Click the FRT number to display the [Frontend Router Detail] screen. Click the FPSU number to display the [FE Power Supply Unit Detail] screen. Refer to "Component Status" for details. |
FE Internal Parts Information
Item | Description |
---|---|
Parts |
The FRT number and the FPSU number are displayed. Click the FRT number to display the [Frontend Router Detail] screen. Click the FPSU number to display the [FE Power Supply Unit Detail] screen. FRT#x FPSU#y x: FRT number y: FPSU number |
Status |
The status of each component is displayed. Refer to "Component Status" for details. |
Status Code |
The status code of each component is displayed. |
Error Code |
The error code of each component is displayed. |