Force Enable Module
Overview
When there is an isolated component from the storage system caused by an error, etc., this function forces the component to be enabled without replacing it (called "force enable" hereinafter).
This function is performed in a situation such as when there is a normal component which has been affected by a failed component and isolated from the storage system.
Availability of Force Enable (For the ETERNUS DX60 S5, the ETERNUS DX100 S5/DX200 S5, and the ETERNUS AF150 S3/AF250 S3) (Force enable is possible: , Force enable is not possible or not applicable: -)
Component | Force Enable | ||||
---|---|---|---|---|---|
ETERNUS DX60 S5 |
ETERNUS DX100 S5/DX200 S5 |
ETERNUS AF150 S3/AF250 S3 |
|||
Controller Enclosure (CE) | - | - | - | ||
Controller Module (CM) | |||||
Memory | - | - | - | ||
BBU | - | - | - | ||
Bootup and Utility Device (BUD) | - | - | (*1) | ||
NAS Engine | - | (*2) | - | ||
32G FC-CA | - | ||||
SFP+ | - | ||||
16G FC-CA | (*3) | ||||
SFP+ | |||||
8G FC-CA | (*3) | - | - | ||
SFP+ | - | - | |||
10G iSCSI-CA | - | ||||
SFP+ | - | ||||
10G Base-T iSCSI | (*3) | ||||
Port | - | - | - | ||
1G iSCSI-CA | (*3) | - | |||
Port | - | - | - | ||
10G NAS-CA | - | - | |||
SFP+ | - | - | |||
1G NAS-CA | - | - | |||
Port | - | - | - | ||
12G SAS-CA | (*3) | ||||
SFP | |||||
Mid Plane (MP) | - | - | - | ||
Power Supply Unit (PSU) |
- | - | - | ||
Drive | |||||
Power Cord | - | - | - | ||
Panel | - | - | - | ||
Drive Enclosure (DE) | - | - | - | ||
Power Supply Unit (PSU) |
- | - | - | ||
Drive | |||||
Panel | - | - | - | ||
I/O Module (IOM) | |||||
Fan Expander Module (FEM) | - | (*4) | |||
Power Cord | - | - | - | ||
SAS Cable | - | - | - |
*1 | : | Force enable is available only for the ETERNUS AF250 S3. |
*2 | : | This item is available only in a Unified Storage environment. |
*3 | : | To perform a force enable of CA, use the force enable function for the CM that includes the CA. |
*4 | : | A component that is installed in high density DEs. |
Availability of Force Enable (For the ETERNUS DX500 S5/DX600 S5 and the ETERNUS AF650 S3) (Force enable is possible: , Force enable is not possible or not applicable: -)
Component | Force Enable Module | |||
---|---|---|---|---|
ETERNUS DX500 S5/DX600 S5 |
ETERNUS AF650 S3 |
|||
Controller Enclosure (CE) | - | - | ||
Controller Module (CM) | ||||
Memory | - | - | ||
BUD | ||||
FAN Unit | - | - | ||
PCIe SW | - | - | ||
IOC Port | - | - | ||
EXP Port | - | - | ||
NAS Engine | (*1) | - | ||
32G FC-CA | ||||
SFP+ | ||||
16G FC-CA | ||||
SFP+ | ||||
10G iSCSI-CA | ||||
SFP+ | ||||
1G iSCSI-CA | - | |||
Port | - | - | ||
iSCSI-RA | ||||
Port | - | - | ||
10G NAS-CA | - | |||
SFP+ | - | |||
1G NAS-CA | - | |||
Port | - | - | ||
CBP | - | - | ||
PCIe Flash Module (PFM) | - | |||
Controller Enclosure Power Supply Unit (CPSU) | - | - | ||
Operation Panel (OPNL) | - | - | ||
Battery Unit | - | - | ||
Battery Control Unit (BCU) | - | - | ||
Battery Unit (BTU) | - | - | ||
Drive |
||||
Drive Enclosure (DE) | - | - | ||
Power Supply Unit (PSU) |
- | - | ||
Drive | ||||
Panel | - | - | ||
I/O Module (IOM) | ||||
Fan Expander Module (FEM) | (*2) | - | ||
Power Cord | - | - | ||
SAS Cable | - | - |
*1 | : | This item is available only in a Unified Storage environment. |
*2 | : | A component that is installed in high density DEs. |
Availability of Force Enable (For the ETERNUS DX8100 S4) (Force enable is possible: , Force enable is not possible or not applicable: -)
Component | Force Enable Module | ||
---|---|---|---|
Controller Enclosure (CE) | - | ||
Controller Module (CM) | |||
Memory | - | ||
BUD | |||
FAN Unit | - | ||
PCIe SW | - | ||
IOC Port | - | ||
EXP Port | - | ||
32G FC-CA | |||
SFP+ | |||
16G FC-CA | |||
SFP+ | |||
10G iSCSI-CA | |||
SFP+ | |||
1G iSCSI-CA | |||
Port | - | ||
iSCSI-RA | |||
Port | - | ||
CEMP | - | ||
CEMP-D | - | ||
Controller Enclosure Power Supply Unit (CPSU) | - | ||
Operation Panel (OPNL) | - | ||
Battery Unit | - | ||
Battery Control Unit (BCU) | - | ||
Battery Unit (BTU) | - | ||
Power Cord | - | ||
Drive | (*1) | ||
Drive Enclosure (DE) | - | ||
Power Supply Unit (PSU) |
- | ||
Drive | |||
Panel | - | ||
I/O Module (IOM) | |||
Power Cord | - | ||
SAS Cable | - |
*1 | : | A component that is installed in the CE of the ETERNUS DX8100 S4. |
Availability of Force Enable (For the ETERNUS DX900 S5 or the ETERNUS DX8900 S4) (Force enable is possible: , Force enable is not possible or not applicable: -)
Component | Force Enable Module | ||
---|---|---|---|
Controller Enclosure (CE) | - | ||
Controller Module (CM) | |||
Memory | - | ||
BUD | |||
FAN Unit | - | ||
PCIe SW | - | ||
IOC Port | - | ||
BE Port | - | ||
FRT Port | - | ||
SVC Port | - | ||
32G FC-CA | |||
SFP+ | |||
16G FC-CA | |||
SFP+ | |||
10G iSCSI-CA | |||
SFP+ | |||
1G iSCSI-CA | |||
Port | - | ||
iSCSI-RA | |||
Port | - | ||
CEMP | - | ||
CEMP-D | - | ||
PCIe Flash Module (PFM) | |||
Controller Enclosure Power Supply Unit (CPSU) | - | ||
Operation Panel (OPNL) | - | ||
Battery Unit | - | ||
Battery Control Unit (BCU) | - | ||
Battery Unit (BTU) | - | ||
Power Cord | - | ||
Drive | |||
Frontend Enclosure (FE) | - | ||
Frontend Enclosure Power Supply Unit (FE PSU) | - | ||
Frontend Router (FRT) | |||
QSFP+ | |||
Service Controller (SVC) | |||
Port | - | ||
Management Cable | - | ||
FE MP | - | ||
FE MP BRG | - | ||
Operation Panel (OPNL) | - | ||
FAN Unit (FANU) | - | ||
FPO-SW | - | ||
Drive Enclosure (DE) | - | ||
Power Supply Unit (PSU) |
- | ||
Drive | |||
Panel | - | ||
I/O Module (IOM) | |||
Fan Expander Module (FEM) | (*1) | ||
Power Cord | - | ||
SAS Cable | - |
*1 | : | A component that is installed in high density DEs. |
Force enable can be performed only on one component at a time.
- Not all components can be forcibly enabled by using this function. Refer to the following tables for the availability of force enable for each part.
When installing the component that cannot be forcibly enabled in the storage system, use the Hot Maintenance or the [Hot Preventive Maintenance] function.
- This function cannot be used under the following conditions:
The selected drive is not in the "Broken" or "Not Supported" state
A component (other than a drive) whose state is other than "Error" is selected
A CM, an IOM, or a SAS cable is selected on a 1CM model
A CA is selected from the [Internal Parts] tab in the [Controller Module Detail] screen for the ETERNUS DX60 S5
Perform the force enable of the NAS Engine by following the instructions given by a maintenance engineer.
To perform a force enable of the CA for the ETERNUS DX60 S5 with a CM-FC (CM with direct mount CA), use the force enable function for the CM that includes the CA.
User Privileges
Availability of Executions in the Default Role
Default role | Availability of executions |
---|---|
Monitor | |
Admin | |
StorageAdmin | |
AccountAdmin | |
SecurityAdmin | |
Maintainer |
Refer to "User Roles and Policies" for details on the policies and roles.
Operating Procedures
Select the component to perform the force enable on, and click [Force Enable] in [Action].
→ A confirmation screen appears.
Click the [OK] button.
→ The force enable starts.
Click the [Done] button to return to the screen when the target component was selected in Step 1.
NoteWhen forcibly enabling a NAS-CA or a NAS-CA port, access to the network may not be available just after mounting the components. Connect to the network after waiting approximately 10 minutes.