Modify REC Multiplicity
Overview
This function specifies multiplicity or priority level when performing REC.
It is not necessary to change the default value (Automatic) for normal use. This function can adjust the copy performance to give priority to REC over work I/O or to reduce the affect on work I/O.
When the Local Storage System and the Remote Storage System are Connected by Remote Connection
If "Automatic" is selected for the specification mode, REC is performed with the recommended multiplicity that is calculated by the obtained round trip time.
If the round trip time is not measured, "***" is displayed in the "Recommended Multiplicity" field.
To display the recommended multiplicity, use the [Get Round Trip Time] function.
If "Manual" is selected for the specification mode, REC will be performed with the specified multiplicity.
When the Local Storage System and the Remote Storage System are Connected by Direct Connection
When the priority level is "Automatic", REC is performed using the priority level that is specified with the [Modify EC/OPC Priority] function.
When the priority level is from "1" to "8", REC is performed using the specified priority level.
Registering the Advanced Copy function license or the Storage Cluster function license (*1) is required to use this function.
*1 : The Storage Cluster function license must be registered using ETERNUS SF Storage Cruiser. If "***" is displayed in the "Recommended Multiplicity" field of the Remote Box ID List, and "Automatic" has been selected for the specification mode, REC will not be performed with the appropriate multiplicity. To select "Automatic", measure the round trip time in advance. Refer to the [Measure Round Trip Time] function for details.
If the path between local and remote storage systems has been changed, measure the round trip time and set the multiplicity again.
User Privileges
Availability of Executions in the Default Role
Default role | Availability of executions |
---|---|
Monitor | |
Admin | |
StorageAdmin | |
AccountAdmin | |
SecurityAdmin | |
Maintainer |
Refer to "User Roles and Policies" for details on the policies and roles.
Settings
In this screen, specify the REC Multiplicity.
Remote Box ID List
Item | Description | Setting values |
---|---|---|
Remote Box ID |
The Box ID for the remote storage system is displayed. |
|
Connection Type |
The type of connection to the remote storage system that has a path to the local storage system is displayed. Direct Remote |
|
Priority Level |
When the "Connection Type" is "Direct", select the priority level. When the "Connection Type" is "Remote", a "-" (hyphen) is displayed.
|
Automatic 1 (corresponds to "Very Low Priority") 2 (corresponds to "Low Priority") 3 4 5 6 7 8 (corresponds to "High Priority") "-" (hyphen) |
Specification Mode |
When the "Connection Type" is "Remote", select the specification mode for multiplicity. When the "Connection Type" is "Direct", a "-" (hyphen) is displayed. |
Automatic Manual "-" (hyphen) |
Multiplicity |
When the "Connection Type" is "Remote" and "Manual" is selected for the specification mode, specify multiplicity (1 to 1024). When "Automatic" is selected, a "-" (hyphen) is displayed. When the "Connection Type" is "Direct", a "-" (hyphen) is displayed. 1 (Default) - 1024 "-" (hyphen) |
|
Present multiplicity |
The current multiplicity setting (1 to 1024) is displayed. When the specification mode is "Automatic", "Automatic" is displayed. When the "Connection Type" is "Direct", a "-" (hyphen) is displayed. |
|
Recommended Multiplicity |
The recommended multiplicity (1 to 1024) is displayed. If the round trip time is not measured, "***" is displayed in the "Recommended Multiplicity" field. When the "Connection Type" is "Direct", a "-" (hyphen) is displayed. |
Advanced Setting
In this screen, specify the copy schedule mode for each remote storage system.
Item | Description | Setting values |
---|---|---|
Remote Box ID |
The Box ID for the remote storage system is displayed. |
|
Copy Schedule Mode |
Select the REC copy schedule mode for each remote storage system. It is not necessary to change the default value (Session Balancing) for normal use.
Caution
|
Session Balancing (Default) Destination RAID Group Balancing |
Operating Procedures
Click the [Modify REC Multiplicity] in [Action].
Specify the parameters, and click the [Set] button.
→ A confirmation screen appears.
CautionWhen "Manual" is selected for "Specification Mode" and numeric characters exceed the allowed range (from 1 to 1024), an error screen appears.
NoteClick [Advanced Setting] to specify the copy schedule mode.
Click the [OK] button.
→ The REC multiplicity settings starts.
Click the [Done] button to return to the [Copy Path] screen.