Smart Setup Wizard

Overview

This function performs the initial settings required to operate the storage system on a series of wizard screens.

The workflow sequence of this wizard is described below.

  1. Select Host

    Select a host to connect to the storage system. Registering a new host is also available.

  2. Select Volume

    Select volumes to be assigned to the host. Creating new volumes is also available.

  3. Set Host Affinity

    Set host affinity between the selected host and volumes.

Caution
  • The ETERNUS DX8100 S4 does not support this function.

  • The volume type to be used as the host connection target is "TPV". If TPPs do not exist in models other than the ETERNUS DX8900 S4, a TPP is automatically created.

    This wizard cannot be used to create volumes in RAID groups or to select arbitrary drives to configure TPPs. Use the dedicated functions provided by the storage system for these operations. Refer to the [Create Volume] function and the [Create Thin Provisioning Pool] function for details.

  • Once this wizard starts, the storage system is occupied (locked state) until it is completed. Note that other users cannot update data that is managed by the storage system during this state.

  • To register a new iSCSI host, advance login to the iSCSI port of the storage system from the host is required.

    For more details, refer to "Configuration Guide -Server Connection- iSCSI" for each OS type.

Note
  • This wizard is started by the following procedure.

    • For models other than the ETERNUS DX8900 S4, the [Start] screen of this wizard is displayed after all of the [Initial Setup] operations are completed. When the [Done] button is clicked after the operation is completed, the [System] screen appears.

    • Click [Smart Setup Wizard] in [Action] under the [System] navigation. When the [Done] button is clicked after the operation is completed, the wizard returns to the [System] screen.

Required Conditions for Using the Smart Setup Wizard

  • The storage system and the host (server) must be connected

  • The initial setup of the storage system must be completed. Refer to the [Initial Setup] function for details.

  • The Thin Provisioning function is enabled

  • An "FC", "iSCSI", or "SAS" host interface must be registered

  • A CA port with a port mode of "CA" or "CA/RA" must exist

  • A CA port without the host affinity setting or a CA port with the affinity mode enabled (On) must exist

  • For the ETERNUS DX8900 S4, TPPs must be created

  • If a TPP is not created in models other than the ETERNUS DX8900 S4, unused drives must be installed

    The required number of drives is as follows:

    • For SSDs or SSD SEDs, five or more drives (except for the ETERNUS DX60 S5)

    • For other drives, seven or more drives

  • The maximum number of volumes is not registered for each model

Operating Specification of the Smart Setup Wizard

The following shows the operating specification of the Smart Setup Wizard.

  • If TPPs do not exist in models other than the ETERNUS DX8900 S4, a TPP is automatically created.

    • The priority for selecting drive types is as follows:

      SSD > SSD SED > Online > Online SED > Nearline > Nearline SED

    • The RAID level and the number of drives for RAID groups that configure the TPP are as follows:
      Drive Type RAID level Number of drives
      SSD / SSD SED (*1) RAID5 Five or more
      For other drives RAID6 Seven or more
      *1  :  Supported by models other than the ETERNUS DX60 S5.
    • The drives in the RAID groups that configure the TPP are as follows:
      • If the drive type is Online, Online SED, Nearline, or Nearline SED, the speed and capacity are the same

      • If the drive speeds are mixed, drives with a higher speed are given priority

      • If the drive capacities are mixed, drives with a larger capacity are given priority

    • A Global Hot Spare is registered for each TPP.

    • The same Deduplication/Compression setting as the Deduplication/Compression mode of the storage system is applied to the TPP.

  • When this wizard is used, host affinity is automatically set by using the following hosts, ports, and LUN groups.
    • All hosts selected in the [Select Host] screen

    • All the CA ports registered in the storage system whose port mode is "CA" or "CA/RA"

      (If multiple types of CAs are installed in the storage system, the selected type of CA is used.)

    • The LUN groups to which all the volumes selected in the [Select Volume] screen belong

  • The maximum number of connectable hosts (the maximum number of HBAs) per CA port is 256 (32 for the ETERNUS DX60 S5).

  • The host response "Default" is assigned to the host.

  • The "Name" entered in this wizard is only the host name. If new TPPs, volumes, and LUN groups are created, the name of the host is used.

Note
  • If a host with the host affinity setting is selected, a volume (TPV) that is selected in this wizard is added to the existing LUN group. If a host without the host affinity setting is selected, a new LUN group is created.

  • Note that this wizard does not create host groups or port groups. Host affinity is configured with the hosts, ports (all the CA ports or CA/RA ports of the selected CA type in the storage system), and LUN groups selected in this wizard.

User Privileges

Availability of Executions in the Default Role

Default role Availability of executions
Monitor  
Admin
StorageAdmin  
AccountAdmin  
SecurityAdmin
Maintainer

Refer to "User Roles and Policies" for details on the policies and roles.

Settings

[Start] Screen

Information for starting this wizard is displayed.

To use volumes other than "TPVs" as a host connection target, click the [Cancel] button to end this wizard.

[CA Type Selection] Screen

This screen appears only when multiple types of CAs are installed in the storage system.

CA Type Selection

Item Description Setting values

CA Type

Select a CA type to connect with the host.

The types of CAs installed in the storage system are displayed.

FC

iSCSI

SAS

The default value varies depending on the CA type installed in the storage system.

The priority of the CA types is as follows:

FC > iSCSI > SAS

[FC Connection Topology Selection] Screen

Select the connection topology of the FC port to connect with the host.

This screen is displayed only when the host affinity setting is not configured for the target port.

FC connection topology selection

Item Description Setting values

Connection

Select the connection topology for the FC port from the "Fabric" or "FC-AL".

  • Fabric

    A connection type that enables simultaneous communication among multiple nodes through a Fibre Channel switch.

  • FC-AL

    A connection type that connects multiple nodes in a loop.

Caution
  • Select "Fabric" for a direct connection when "Transfer Rate" is "16 Gbit/s" or more. Some destination Fibre Channel cards may require Fibre Channel switches. For details, refer to the Fibre Channel card specifications.

  • Select "FC-AL" for a direct connection when "Transfer Rate" is less than "16 Gbit/s". Note that there may be cases when "Fabric" must be selected depending on the Fibre Channel card of the connection destination.

    Refer to "Setting the To-Server Connection Type (Setting the FC Port Parameters)" in "Configuration Guide -Server Connection-" (*1) for details.

    *1  :  Configuration Guide -Server Connection- Fibre Channel/ ETERNUS AF series, ETERNUS DX200F All-Flash Arrays, ETERNUS DX S5/S4/S3 series Hybrid Storage Systems Settings
Note
  • For parameters other than "Connection", the following values are specified for the FC port.
    • If "Connection" is "Fabric", the default FC port parameters are set.

    • If "Connection" is "FC-AL", the default FC port parameters are set for items other than the following.
      • "Automatic" for "Set Loop ID"

      • "Ascending" for "Loop ID"

  • FC port parameters are applied to all FC ports in the storage system (whose port mode is "CA" or "CA/RA").

Fabric

FC-AL

[iSCSI Port IP Address Settings] Screen

Set the IP address of the iSCSI port to connect to the host.

This screen is displayed only when the host affinity setting is not configured for the target port.

iSCSI Port IP Address Setting

Item Description Setting values

New IP Address

Enter a new IPv4 address of the iSCSI port.

Caution
  • Use the IPv4 address for the iSCSI port. Note that the IPv6 address is not supported.

Note
  • Enter a "New IP Address" and click the [All Refresh] button to display the new IP address in "New IP Address" under the iSCSI port list. The new subnet mask is also displayed in "New Subnet Mask".

    For the new IP address, the entered value is used as the starting address and the last three digits (xxx) are set in ascending order. For the new subnet mask, the same value as the current subnet mask is set. If the current subnet mask is not specified, "255.255.255.0" is set.

xxx.xxx.xxx.xxx

xxx: 1 - 255 for the top field (decimal)

xxx: 0 - 255 for other fields (decimal)

Class must be A, B, or C.

iSCSI Port List

Item Description Setting values

Port

The location information of the iSCSI port is displayed.

In the iSCSI port list, iSCSI ports without a default gateway address setting are displayed.

For the ETERNUS DX900 S5 or the ETERNUS DX8900 S4

CE#x CM#y CA#z Port#w

For the other models

CM#y CA#z Port#w

x: CE number

y: CM number

z: CA number

w: Port number

New IP Address

Enter a new IP address to change the current IP address.

If the current IP address is not changed, this item remains a "-" (hyphen). If a value is not specified, the "Current IP Address" is set for the storage system.

There are two methods available for setting a new IP address:

  • Set new IP addresses in a single process

    Refer to Note for "New IP Address" in the "iSCSI Port IP Address Setting" field.

  • Set a new IP address individually

    Directly enter an IPv4 address of the iSCSI port.

Caution
  • For the iSCSI port whose current IP address is not specified, the "New IP Address" setting is required.

  • Use the IPv4 address for the iSCSI port. Note that the IPv6 address is not supported.

  • IP addresses that are duplicated in the following manner cannot be specified:
    • There are multiple combinations of "New IP Address" and "New Subnet Mask"

    • For ports without a new IP address setting, the combination of "Current IP Address" and "Current Subnet Mask" is the same as that of "New IP Address" and "New Subnet Mask"

xxx.xxx.xxx.xxx

xxx: 1 - 255 for the top field (decimal)

xxx: 0 - 255 for other fields (decimal)

Class must be A, B, or C.

"-" (hyphen)

New Subnet Mask

Enter a new subnet mask to change the current subnet mask.

If the current subnet mask is not changed, this item remains a "-" (hyphen). If a value is not specified, the "Current Subnet Mask" is set for the storage system.

There are two methods available for setting a new subnet mask:

  • Set a new subnet mask when setting the new IP address

    Refer to Note for "New IP Address" in the "iSCSI Port IP Address Setting" field.

  • Set a new subnet mask individually

    Directly enter a subnet mask of the iSCSI port.

Caution
  • For the iSCSI port whose current subnet mask is not specified, the "New Subnet Mask" setting is required.

Numeric characters

255.0.0.0 - 255.255.255.252

"-" (hyphen)

Current IP Address

The current IP address of the iSCSI port is displayed.

If the current IP address is not specified, a "-" (hyphen) is displayed.

Subnet Mask

The current subnet (255.0.0.0 to 255.255.255.252) mask of the iSCSI port is displayed.

If the current subnet mask is not specified, a "-" (hyphen) is displayed.

iSCSI Name

The iSCSI name of the iSCSI port (up to 223 alphanumeric characters) is displayed.

[Register Host] Screen

A list of the hosts that have not been registered in the storage system is displayed. In this screen, register hosts.

Select Host

Item Description

Checkbox to select a host

Select the checkbox of the host that is to be registered in the storage system.

Caution
  • Up to 500 hosts (*1) can be registered with this wizard. If 300 hosts have already been registered, 200 hosts can be added.

    *1  :  Total of all hosts, regardless of the interface type. For the ETERNUS DX60 S5, the maximum number of hosts is 128.

WWN

The WWN of the host is displayed.

This item is displayed when the CA type is "FC" or "SAS".

In this wizard, "SAS Address" is referred to as "WWN".

iSCSI Name

The iSCSI name of the host is displayed.

This item is displayed when the CA type is "iSCSI".

Setting Host NickName

Item Description Setting values

Name

Enter the name of the host that is to be registered in the storage system.

An existing host name cannot be specified.

Up to 16 alphanumeric characters, symbols (except "," (comma) and "?"), and spaces

Note that "%" cannot be used as the first character.

Refer to "Naming Conventions for Registering Hosts" for details.

Default:

  • For FC host, "FC"

  • For iSCSI host, "iSCSI"

  • For SAS host, "SAS"

Naming Conventions for Registering Hosts

  • A name is automatically added to a host with the "Name" and a suffix number "x" (decimal serial numbers starting with "0").

    (Example 1) When "Name" is "FC" and a single host is selected → Example host name is "FC0"

    (Example 2) When "Name" is "FC" and two hosts are selected → Example host names are "FC0" and "FC1"

  • When the host name including the suffix number "x" has more than 16 characters, the excess number of characters is deleted from the "host name", starting with the last character and a suffix number "~x" will be added. Then, the name will contain only 16 characters.

    (Example) When "Name" is "FC_HOST_ABCDEFGH" (16 characters) and two hosts are selected → Example host names are "FC_HOST_ABCDEF~0" and "FC_HOST_ABCDEF~1".

  • When a host name including the suffix number already exists, the suffix number is increased by one (+1). The suffix number is increased by one (+1) until no host names overlap.

[Select Host] Screen

A list of the registered hosts in the storage system is displayed. In this screen, select a host to which to assign volumes.

Host Selection

Item Description Setting values

Checkbox to select a host

Select a host to which to assign volumes.

The following hosts can be selected.

  • Hosts that are registered with this wizard

  • Hosts that are already registered in the storage system, but host affinity is not set

  • Hosts that are already registered in the storage system and host affinity is set, but are connected to only one LUN group

Note
  • The hosts selected in this item are connected to all the ports. Up to 256 hosts can be selected (up to 32 hosts can be selected for the ETERNUS DX60 S5).

  • Hosts that are registered with this wizard are automatically selected.

  • If a host in the "Active" state is selected, hosts with the host affinity setting for the same LUN group are automatically selected.

  • If a host in the "Active" state is selected, hosts with the host affinity setting for a different LUN group cannot be selected.

  • The "Select All" checkbox on the top left is not displayed.

  • The following hosts with the host affinity setting cannot be selected. Checkbox cannot be selected.
    • Hosts that are connected to multiple LUN groups

    • Other hosts that are connected to LUN groups that cannot be selected

    • Hosts that are connected to LUN groups that use LUN#256 onward

Checkbox

Selected

Cleared

Name

The name of the host is displayed.

WWN

The WWN of the host is displayed.

This item is displayed when the CA type is "FC" or "SAS".

iSCSI Name

The iSCSI name of the host is displayed.

This item is displayed when the CA type is "iSCSI".

Status

Whether the host is used ("Active") or not used ("Inactive") for the host affinity setting is displayed.

  • Active

    The host is used for the host affinity setting.

  • Inactive

    The host is not used for the host affinity setting.

LUN Group

The name of the LUN group to which the volumes with the host affinity setting belong is displayed.

If there are no LUN groups with the host affinity setting, the field is blank.

[Register Volume] Screen

Register volumes that are to be connected to the host.

New Volume

Item Description Setting values

Capacity

Enter the capacity of the volume to be created and select the unit of capacity.

Up to a 15-digit number including the "." (decimal point) can be input. Note that when "MB" is selected, the specified value is rounded down to the nearest whole number. When "GB" or "TB" is selected, the specified value is converted to "MB" and rounded down to the nearest whole number.

Note
  • The number of entered characters includes the "." (decimal point) and the "0" before the decimal point.

    (Example) 0.1234567890123 (15 characters)

24 MB - 128 TB (numeric characters)

Unit: TB/GB/MB

Number of Volumes

Specify the number of volumes to be created.

[The maximum number of volumes that can be created for each model]

  • ETERNUS DX60 S5: 1024

  • ETERNUS DX100 S5: 4096

  • ETERNUS DX200 S5: 8192

  • ETERNUS DX500 S5/DX600 S5: 16384

  • ETERNUS DX900 S5: 65535

  • ETERNUS DX8900 S4: 65535

  • ETERNUS AF150 S3: 4096

  • ETERNUS AF250 S3: 8192

  • ETERNUS AF650 S3: 16384

Note
  • For the ETERNUS DX900 S5 or the ETERNUS DX8900 S4, up to 1024 volumes can be created at a time. Note that this limitation does not apply to other models.

ETERNUS DX60 S5:

1 - 1024

ETERNUS DX100 S5:

1 - 4096

ETERNUS DX200 S5:

1 - 8192

ETERNUS DX500 S5/DX600 S5:

1 - 16384

ETERNUS DX900 S5:

1 - 1024

ETERNUS DX8900 S4:

1 - 1024

ETERNUS AF150 S3:

1 - 4096

ETERNUS AF250 S3:

1 - 8192

ETERNUS AF650 S3:

1 - 16384

1 (Default)

Item Description

Radio buttons to select a TPP

Select a TPP to create the volume.

Thin Provisioning Pool Name

The TPP name is displayed.

Drive Type

The type of drive that configures the TPP is displayed.

If multiple drive types are used in the TPP, the drive type is displayed as described below.

  • If only "Online" type drives are used or if both "Online" and "Nearline" type drives are used, "Online" is displayed.

  • If only "Online SED" type drives are used or if both "Online SED" and "Nearline SED" type drives are used, "Online SED" is displayed.

  • If a single SSD type (SSD-H/SSD-M/SSD-L) is used or if multiple SSD types (SSD-H/SSD-M/SSD-L) are used, "SSD" is displayed.

  • If a single SSD type (SSD-H SED/SSD-M SED/SSD-L SED) is used or if multiple SSD types (SSD-H SED/SSD-M SED/SSD-L SED) are used, "SSD SED" is displayed.

Online

Nearline

SSD

Online SED

Nearline SED

SSD SED

Total Capacity

The total capacity [PB/TB/GB] of TPP is displayed.

Total Free Capacity

The total capacity [PB/TB/GB/MB] of free space in the TPP is displayed.

Provisioned Capacity

The total logical capacity [PB/TB/GB/MB] of TPVs in the TPP is displayed.

Deduplication/Compression Status of the Created Volumes

The Deduplication/Compression status of the volumes to be created varies depending on the Deduplication/Compression setting of the selected TPP.

Deduplication/Compression setting for the destination TPP Volumes that are to be created
Deduplication Compression
Enable Enable Deduplication/Compression Volumes where both Deduplication and Compression are enabled
Enable Disable Deduplication/Compression Volumes where only Deduplication is enabled
Disable Enable Deduplication/Compression Volumes where only Compression is enabled
Disable Disable TPVs for SAN where both Deduplication and Compression are disabled

[Select Volume] Screen

Select volumes to be assigned to the host.

Volume Selection

Item Description

Checkbox to select a volume

Select the checkbox for the volume that is to be assigned to the host.

Only TPVs that can be registered in LUN groups are displayed in the volume list.

The checkboxes for the volumes with the following conditions are selected (specified as a registration target volume in the LUN group) by default. If these volumes are not registered in the LUN group, clear the checkbox.

  • Volumes that are created with this wizard

  • Volumes that are registered in the LUN group where host affinity is set with the host selected in the [Select Host] screen

Note
  • Up to 256 volumes can be selected. This is the number of volumes that can be registered in a single LUN group.

No.

The volume number is displayed.

Name

The volume name is displayed.

Capacity

The volume capacity (24 MB to 128 TB) is displayed.

Host LUN Setting

If the volume is already assigned to the host LUN (or the volume is already registered in the LUN group), "Enable" is displayed.

If the volume is not assigned to the host LUN, the field is blank.

Current Host LUN

If the volume is currently assigned to the host LUN, the host LUN is displayed.

If the volume is not currently assigned to the host LUN, the field is blank.

New

For volumes created with this wizard, "Yes" is displayed.

For volumes not created with this wizard, the field is blank.

[Check Automatic TPP Creation] Screen

Configuration of the TPP that is automatically created in the storage system is displayed.

Thin Provisioning Pool Configuration

Item Description

Number

The TPP number is displayed.

A TPP number is allocated from the smallest unused decimal number in ascending order.

Name

The TPP name is displayed.

The name specified in the [Register Host] Screen is used as the TPP name.

Drive Type

The type of drive that configures the TPP is displayed.

The priority for selecting drive types is as follows:

SSD > SSD SED > Online > Online SED > Nearline > Nearline SED

The drive type is determined based on whether the following number of unused drives is available for the relevant drive type.

  • For SSDs or SSD SEDs, 5 to 48 drives

  • For other drives, 7 to 48 drives (for the ETERNUS DX60 S5, 7 to 24 drives)

Online

Nearline

SSD

Online SED

Nearline SED

SSD SED

Total Capacity

The total capacity [PB/TB/GB] of TPP is displayed.

This item shows the total capacity of the TPP when the following RAID groups are configured with the selected drive.

  • For SSDs or SSD SEDs, RAID5

  • For other drives, RAID6

If the total capacity of the created TPP reaches the maximum pool capacity of the storage system, the total capacity is recalculated after one drive is removed from the configuration.

Number of Drives

The number of drives that are used for the automatic TPP creation is displayed.

Number of Drives = Number of drives that configure the TPP + One Global Hot Spare

Deduplication/Compression

If Deduplication/Compression of the storage system is enabled, Deduplication/Compression is also enabled for the TPP that is to be created.

If Deduplication/Compression of the storage system is disabled, Deduplication/Compression is also disabled for the TPP that is to be created.

[Review Summary] Screen

The settings that are specified in this wizard are displayed. Confirm the setting contents.

Selected Host

Item Description

Name

The name of the host where host affinity is set is displayed.

WWN

The WWN of the host where host affinity is set is displayed.

This item is displayed when the CA type is "FC" or "SAS".

iSCSI Name

The iSCSI name of the host where host affinity is set is displayed.

This item is displayed when the CA type is "iSCSI".

Selected Volume (LUN Group: LUN Group Name [Create]) (*1)Selected Volume (LUN Group: LUN Group Name [Modify]) (*2)

Item Description

No.

The volume number is displayed.

Name

The volume name is displayed.

Capacity

The volume capacity (24 MB to 128 TB) is displayed.

Current Host LUN

If the volume is currently assigned to the host LUN, the host LUN is displayed.

If the volume is not currently assigned to the host LUN (or the volume is created with this wizard), the field is blank.

New Host LUN

For volumes that are created with this wizard, the host LUN that is to be assigned to the volume is displayed.

If the volume is currently assigned to the host LUN, the field is blank.

If the volume is currently assigned to the host LUN, but the volume is deleted from the LUN group using the [Select Volume] screen, "Remove" is displayed.

*1  :  If only unused hosts without the host affinity setting are selected, the [Create] screen appears.
*2  :  If at least one host with the host affinity setting is selected, the [Modify] screen appears.

Operating Procedures

  1. Click [Smart Setup Wizard] in [Action].

    → The [Start] Screen appears.

  2. Click the [Next >>] button.

    → The next screen varies depending on whether multiple types of CAs are installed in the storage system.

    • This screen appears only when multiple types of CAs are installed in the storage system.

      → The [CA Type Selection] Screen appears.

    • If only "FC" type CAs are installed

      The next screen varies depending on whether host affinity is set.

    • If only "iSCSI" type CAs are installed

      The next screen varies depending on whether host affinity is set.

    • If only "SAS" type CAs are installed

      The next screen varies depending on whether hosts are registered.

      • If hosts are registered in the storage system

        → The [Select Host] Screen appears. Proceed to Step 7.

      • If hosts are not registered in the storage system

        → The [Register Host] Screen appears. Proceed to Step b under "When selecting by registering a new host in the storage system" of Step 7.

    Caution
  3. Select a CA type and click the [OK] button.

    → The displayed screen varies depending on the CA type.

    • If "FC" is selected

      The next screen varies depending on whether host affinity is set.
    • If "iSCSI" is selected

      The next screen varies depending on whether host affinity is set.
    • If "SAS" is selected

      The next screen varies depending on whether hosts are registered.
      • If hosts are registered in the storage system

        → The [Select Host] Screen appears. Proceed to Step 7.

      • If hosts are not registered in the storage system

        → The [Register Host] Screen appears. Proceed to Step b under "When selecting by registering a new host in the storage system" of Step 7.

  4. Select a connection topology of the FC port and click the [OK] button.

    → The [Select Host] Screen appears. Proceed to Step 7.

  5. Set the IP address and the subnet mask of the iSCSI port to connect to the host.

    Check the "Current IP Address" and the "Current Subnet Mask" in the iSCSI port list. The following procedure varies depending on whether the "Current IP Address" and the "Current Subnet Mask" are used.

    • If the "Current IP Address" and the "Current Subnet Mask" are to be used as is, click the [Cancel] button.

      → The [Select Host] Screen appears. Proceed to Step 7.

    • If either or both of "Current IP Address" and "Current Subnet Mask" are not used, perform one of the following procedures.
      • To set "New IP Address" and "New Subnet Mask" with a single operation, enter a "New IP Address" and click the [All Refresh] button in the "iSCSI Port IP Address Setting" field.

        → New IP addresses and subnet masks are set for the number of ports in "New IP Address" and "New Subnet Mask" of the iSCSI port list.

      • To individually set a "New IP Address" or a "New Subnet Mask", directly enter an IP address or a subnet mask for each port.

  6. Click the [OK] button.

    → The [Select Host] Screen appears.

  7. Select a host to which to assign volumes.

    Note
    • When selecting by registering a new host in the storage system
      1. Click the [Register] button.

        → The [Register Host] Screen appears.

      2. Select a host to register in the storage system, enter a nickname, and click the [OK] button.

        → The [Select Host] Screen appears. Proceed to "When selecting from the host list" in Step 7.

        Caution
        • If the host to be registered is not displayed in the host selection list, perform the following procedure and then click the [Refresh] button.
          • Make sure that there is no error in the connection environment, such as the connection between the host and the switch, and the CA port settings of the storage system.

          • For iSCSI hosts, check whether the login operation has been completed. For more details, refer to "Configuration Guide -Server Connection- iSCSI" for each OS type.

        Note
        • The "Name" entered in this screen is used not only for the host name, but also for the new TPP name, volume name, and LUN group name.

    • When selecting from the host list
      1. Select a host from the host list and click the [Next >>] button.

        → The next screen varies depending on whether TPPs are registered in the storage system.

  8. Check the TPP configuration to be registered in the storage system and click the [OK] button.

    → The [Register Volume] Screen appears.

    Note
    • The configuration of the TPPs to be registered in the storage system is displayed in the "Thin Provisioning Pool Configuration" field. Refer to [Check Automatic TPP Creation] Screen for details.

    • If a drive that is not in the normal state exists in the storage system, the operation cannot be continued. Click the [Cancel] button to end this wizard. After repairing the drive, re-execute this wizard.

    • To change the TPP configuration or the Deduplication/Compression setting, click the [Cancel] button to end this wizard.

  9. Enter the volume capacity and number of volumes to be created, and then click the [OK] button.

    → The [Select Volume] Screen appears.

    Note
  10. Select a volume to assign to the host and click the [Next >>] button.

    → The [Review Summary] Screen appears.

    Note
  11. Check the setting contents and click the [Next >>] button.

    → A confirmation screen appears.

  12. Click the [OK] button.

    → The modification of the host affinity starts.

    Note
    • Host affinity is set with the configuration displayed in the [Review Summary] Screen.
      • A new LUN group is created with the volumes displayed in "Selected Volume (LUN Group: LUN Group Name [Create])".

        The name specified in the [Register Host] Screen is used as the LUN group name.

      • The existing LUN group is changed with the volumes displayed in "Selected Volume (LUN Group: LUN Group Name [Modify])".

      • Configure host affinity using the selected host, all the CA ports or CA/RA ports of the selected CA type, and the LUN groups.

    • The specified paths between the hosts and ports can be edited. Refer to the [Modify Host Affinity] function for details.

  13. Click the [Done] button to return to the [System] screen.

    Note
    • Confirm that the volume assigned with this wizard can be successfully accessed from the host.

    • To assign volumes to other hosts, click the [Restart] button to re-execute this wizard.