ONTAP 9.13.1 commands

storage shelf show

Display a list of storage shelves

Availability: This command is available to cluster administrators at the admin privilege level.

Description

The storage shelf show command displays information about all the storage shelves in the storage system. If no parameters are specified, the default command displays the following information about the storage shelves:

  • Shelf Name

  • Shelf ID

  • Serial Number

  • Model

  • Module Type

  • Status

To display detailed profile information about a single storage shelf, use the -shelf parameter.

Parameters

{ [-fields <fieldname>,…​]

Displays the specified fields for all the storage shelves, in column style output.

| [-bay ]

Displays the following details about the disk bays in the storage shelf:

  • The unique positional identifier of the disk bay

  • Whether a disk drive is installed in the bay

  • Bay type

  • Operational status of the disk bay

| [-connectivity ]

Displays the following details about the connectivity from the node to the storage shelf:

  • Node name

  • Initiator side switch port

  • Target side switch port

  • World-wide port name

  • Target Port Group Number (TPGN)

| [-cooling ]

Displays the following details about the cooling elements and temperature sensors of the storage shelf:

  • Element ID of the cooling fan

  • The current speed of the cooling fan in revolutions per minute (rpm)

  • Operational status of the cooling fan

  • Sensor ID of the temperature sensor element

  • Temperature at the sensor in degrees Celsius

  • Whether the current temperature at the sensor is the ambient temperature

  • Low critical threshold value for the temperature sensor

  • Low warning threshold value for the temperature sensor

  • High critical threshold value for the temperature sensor

  • High warning threshold value for the temperature sensor

  • Operational status for the temperature sensor

| [-errors ]

Displays the following error status information about the storage shelves that have errors:

  • Error type

  • Error description

| [-module ]

Displays the following details about the I/O modules attached to the storage shelf:

  • Module ID

  • Module part number

  • Serial number of the Enclosure Services Controller Electronics element

  • Whether monitoring is enabled on this module

  • Whether this module is the SAS expander master module

  • Whether this module is the element reporting

  • Version of the firmware installed on the module

  • Latest firmware revision

  • Number of times, since the last boot, that this module has been swapped

  • Operational status of the module

| [-port ]

Displays the following details about the storage shelf ports:

  • Expander phy element identifier

  • SAS shelf port type

  • World-wide Port Name of the SAS port

  • Operational physical link rate of the SAS port in Gb/s

  • Negotiated physical link rate of the SAS port in Gb/s

  • Power status of the SAS port

  • Status of the SAS port

  • Fibre Channel shelf port ID

  • Fibre Channel shelf port type

  • Fibre Channel shelf port status

| [-power ]

Displays the following details about the power supplies, voltage sensors, and current sensors of the storage shelf:

  • Power Supply Unit (PSU) number

  • PSU type

  • PSU part number

  • PSU serial number

  • PSU power rating in watts

  • PSU crest factor

  • Power drawn from the PSU in watts

  • Whether the PSU can be reset via software control

  • Whether the auto power reset of the PSU is enabled

  • PSU firmware revision

  • Operational status of the PSU

  • Voltage sensor number

  • Voltage detected by the voltage sensor, in volts (V)

  • Operational status of the voltage sensor

  • Current sensor number

  • Current detected by the current sensor, in milliamps (mA)

  • Operational status of the current sensor

| [-instance ]

Displays expanded information about all the storage shelves in the system.

[-shelf <text>] - Shelf Name

Displays information only about the storage shelves that match the names you specify.

[-node {<nodename>|local}] - Node

Displays information only about the storage shelves that are attached to the node you specify.

[-shelf-uid <text>] - Shelf UID

Displays information only about the storage shelf that matches the shelf UID you specify. Example: `50:05:0c:c0:02:10:64:26 `

[-stack-id {<integer>|-}] - Stack ID

Displays information only about the storage shelves that are attached to the stack that matches the stack ID you specify

[-shelf-id <text>] - Shelf ID

Displays information only about the storage shelves that match the shelf ID you specify.

[-module-type {unknown|atfcx|esh4|iom3|iom6|iom6e|iom12|iom12e|iom12f|nsm100|nsm8e|psm3e|iom12b|iom12g}] - Shelf Module Type

Displays information only about the storage shelves that match the module-type you specify.

[-connection-type {unknown|fc|sas|nvme}] - Shelf Connection Type

Displays information only about the storage shelves that match the connection type you specify. Example: FC or SAS.

[-is-local-attach {true|false}] - Is the Shelf Local to This Cluster?

Displays information only about the storage shelves that are local (TRUE) or remote (FALSE) to this cluster.

[-vendor <text>] - Shelf Vendor

Displays information only about the storage shelves that match the vendor you specify.

[-product-id <text>] - Shelf Product Identification

Displays information only about the storage shelves that match the product ID you specify.

[-serial-number <text>] - Shelf Serial Number

Displays information only about the storage shelf that matches the serial number you specify.

[-disk-count {<integer>|-}] - Disk Count

Displays information only about the storage shelves that have the disk count you specify.

[-state {unknown|no-status|init-required|online|offline|missing}] - Shelf State

Displays information only about the storage shelves that are in the state you specify.

[-op-status {unknown|normal|warning|error|critical|standby-power}] - Shelf Operational Status

Displays information only about the storage shelves that are currently operating under the status condition you specify.

[-bay-id {<integer>|-}] - Bay ID

Displays information only about the storage shelves that have bays that match the bay ID you specify.

[-bay-type {unknown|single-disk|multi-lun}] - Bay Type

Displays information only about the storage shelves that have bays that match the type of bay you specify.

[-bay-has-disk {true|false}] - Bay Has Disk

Displays information only about the storage shelves that have bays with disk drives inserted in them (true) or empty bays (false).

[-bay-op-status {unknown|normal|error}] - Bay Operational Status

Displays information only about the storage shelves that have bays that match the operational state you specify.

[-controller {<nodename>|local}] - Controller Name

Displays information only about the storage shelves that are connected to the node you specify.

[-controller-uuid <text>,…​] - Controller UUID

Displays information only about the storage shelves that are connected to the node UUID you specify.

[-initiator <text>,…​] - Initiator

Displays information only about the storage shelves that are visible to the initiator you specify.

[-initiator-wwpn <text>,…​] - Initiator WWPN

Displays information only about the storage shelves that are visible to the initiator WWPN you specify.

[-initiator-side-switch-port <text>,…​] - Initiator Side Switch Port

Displays information only about the storage shelves that are visible to an initiator connected to the switch port you specify.

[-target-side-switch-port <text>,…​] - Target Side Switch Port

Displays information only about the storage shelves visible on target ports identified by the switch port to which they are connected.

[-target-port <text>,…​] - Target Port

Displays information only about the storage shelves visible on the specified target ports identified by their World-Wide Port Name (WWPN).

[-tpgn {<integer>|-}] - Target Port Group Number

Displays information only about the storage shelves that belong to the Target Port Group Name (TPGN) you specify.

[-port-speed {<integer>|-}] - Port Speed

Displays information only about the storage shelves with ports that match the port speed you specify.

[-io-kbps {<integer>|-}] - Kbytes/sec on Storage Shelf

Displays information only about the storage shelves visible to an initiator that has executed I/O at the throughput you specify.

[-iops {<integer>|-}] - Number IOPS per Second on Storage Shelf

Displays information only about the storage shelves visible to an initiator that has executed the number of IOPs you specify.

[-current-sensor-id {<integer>|-}] - Current Sensor ID

Displays information only about the storage shelves with current sensor that matches the current sensor ID you specify.

[-current-sensor-location <text>,…​] - Current Sensor Location

Displays information only about the storage shelves with current sensors installed at the location you specify.

[-current-sensor-reading {<integer>|-}] - Current Sensor Reading

Displays information only about the storage shelves with current sensors that match the current reading you specify.

[-current-op-status {unknown|normal|over-current-critical|under-current-critical|not-supported|not-installed}] - Operational Status

Displays information only about the storage shelves with current sensors that match the operational status you specify.

[-fan-id {<integer>|-}] - Fan ID

Displays information only about the storage shelves with cooling fans that match the fan IDs you specify.

[-fan-location <text>,…​] - Fan Location

Displays information only about the storage shelves with cooling fans installed.

[-fan-rpm {<integer>|-}] - Fan Rotation Per Minute

Displays information only about the storage shelves with cooling fans that match the rpm rate you specify.

[-fan-op-status {unknown|normal|off|error|not-supported|not-installed}] - Fan Operational Status

Displays information only about the storage shelves with cooling fans that match the operational status you specify.

[-module-id <text>,…​] - Module ID

Displays information only about the storage shelves with an I/O module that matches the module ID you specify.

[-module-location <text>,…​] - Module Location

Displays information only about the storage shelves with I/O modules in the specified shelf module slots.

[-module-part-number <text>,…​] - Module Part Number

Displays information only about the storage shelves with I/O modules that match the module part numbers you specify.

[-is-sas-master-module {true|false}] - Is SAS Expander Master Module?

Displays information only about the storage shelves with a SAS master I/O module (true) or an I/O module that is not a SAS master (false). This parameter applies only to SAS shelves.

[-is-monitor-active {true|false}] - Is Monitor Active?

Displays information only about the storage shelves whose monitoring is enabled (true) or disabled (false).

[-enclosure-type <text>,…​] - Module Enclosure Type

Displays information only about the storage shelves that match the enclosure types you specify.

[-es-serial-number <text>,…​] - ES Electronics Element Serial Number

Displays information only about the storage shelves with I/O modules that match the electronics serial numbers you specify.

[-module-fru-id <text>,…​] - Field Replaceable Unit ID

Displays information only about the storage shelves with I/O modules that match the field replaceable unit (FRU) IDs you specify.

[-module-is-reporting-element {true|false}] - Is Reporting Element?

Displays information only about the storage shelves with element reporting I/O modules (true) or not (false).

[-module-fw-revision <text>,…​] - Firmware Revision

Displays information only about the storage shelves with I/O modules that match the firmware revision you specify.

[-module-latest-fw-revision <text>,…​] - Latest Firmware Revision

Displays information only about the storage shelves with I/O modules that match the latest firmware revision you specify.

[-module-fw-progress {not-available|ready|in-progress|failed}] - Module Firmware Progress

Displays information only about the storage shelves with I/O modules that match the specified firmware update progress.

[-module-swap-count {<integer>|-}] - Module Swap Count

Displays information only about the storage shelves whose I/O modules have been swapped the specified number of times.

[-module-op-status {unknown|normal|warning|error|not-installed}] - Module Operational Status

Displays information only about the storage shelves with I/O modules that match the operational status you specify.

[-sas-port-id <text>,…​] - Port ID

Displays information only about the storage shelves with SAS Ports that match the port IDs you specify.

[-sas-port-type {unknown|circle|square|sil|disk|in|out|unused|host|dcm|aux1|aux2|hi_ho|a_to_b|b_to_a}] - Port Type

Displays information only about the storage shelves with SAS Ports that match the SAS port type you specify.

[-sas-port-wwpn <text>,…​] - Port World Wide Port Name

Displays information only about the storage shelves with SAS Ports that match the World-Wide Port Names you specify.

[-sas-port-speed <text>,…​] - Port Speed

Displays information only about the storage shelves with SAS Ports that match the port speed you specify.

[-sas-negotiated-port-speed <text>,…​] - Negotiated Port Speed

Displays information only about the storage shelves with SAS Ports that match the negotiated port speed you specify.

[-sas-port-power-status <text>,…​] - Port Power Status

Displays information only about the storage shelves with SAS Ports that match the power status you specify.

[-sas-port-op-status {error|normal|off|unknown|byp-bad-term|bad-zone-recovery|byp_clk_thr|byp_comma_los|byp_crc_brst_thr|byp_data_timeout|byp_drv_fault|byp_drv_pcycle|byp_drv_pwr|byp_drv_self|byp_gen|byp_init|byp_lip_brst_thr|byp_lip_f8|byp_lip_rate_thr|byp_lipf7|byp_ltbi|byp_man|byp_no_drive|byp_osc|byp_other_thr|byp_rec_los|byp_rport|byp_stall_thr|byp_wrd_brst_thr|byp_wrd_rate_thr|byp_xmit_fault|diag_transmit|inserted|loopback|status_unknown|warn_high_clk_delta|warn_high_crc_rate|warn_high_lip|warn_high_wrd_rate|term|phy_dis_clk_fault|phy_dis_crc_err|phy_dis_crc_err_burst|phy_dis_disparity|phy_dis_disparity_burst|phy_dis_emulate_reserve|phy_dis_inval_dword|phy_dis_inval_dword_burst|phy_dis_loss_dword|phy_dis_loss_dword_burst|phy_dis_man_smp|phy_dis_manual|phy_dis_mirrored|empty|phy_dis_phy_change|phy_dis_phy_change_burst|phy_dis_phy_reset|phy_dis_phy_reset_burst|phy_dis_phy_unused|phy_ena|phy_ena_not_attach|phy_ena_unknown|phy_unknown|phy_dis_illegal}] - Port Operational Status

Displays information only about the storage shelves with SAS Ports that match the operational status you specify.

[-sas-port-module-id {A|B}] - Port Module ID

Displays information only about the storage shelves with SAS Ports that match the module ID you specify.

[-fc-port-id <text>,…​] - Fibre Channel Port ID

Displays information only about the storage shelves with FC Ports that match the port IDs you specify.

[-fc-port-mode {unknown|circle|square|sil|disk|in|out|unused|host|dcm|aux1|aux2|hi_ho|a_to_b|b_to_a}] - Fibre Channel Port Mode

Displays information only about the storage shelves with FC Ports that match the port modes you specify.

[-fc-port-op-status {error|normal|off|unknown|byp-bad-term|bad-zone-recovery|byp_clk_thr|byp_comma_los|byp_crc_brst_thr|byp_data_timeout|byp_drv_fault|byp_drv_pcycle|byp_drv_pwr|byp_drv_self|byp_gen|byp_init|byp_lip_brst_thr|byp_lip_f8|byp_lip_rate_thr|byp_lipf7|byp_ltbi|byp_man|byp_no_drive|byp_osc|byp_other_thr|byp_rec_los|byp_rport|byp_stall_thr|byp_wrd_brst_thr|byp_wrd_rate_thr|byp_xmit_fault|diag_transmit|inserted|loopback|status_unknown|warn_high_clk_delta|warn_high_crc_rate|warn_high_lip|warn_high_wrd_rate|term|phy_dis_clk_fault|phy_dis_crc_err|phy_dis_crc_err_burst|phy_dis_disparity|phy_dis_disparity_burst|phy_dis_emulate_reserve|phy_dis_inval_dword|phy_dis_inval_dword_burst|phy_dis_loss_dword|phy_dis_loss_dword_burst|phy_dis_man_smp|phy_dis_manual|phy_dis_mirrored|empty|phy_dis_phy_change|phy_dis_phy_change_burst|phy_dis_phy_reset|phy_dis_phy_reset_burst|phy_dis_phy_unused|phy_ena|phy_ena_not_attach|phy_ena_unknown|phy_unknown|phy_dis_illegal}] - Fibre Channel Port Operational Status

Displays information only about the storage shelves with FC Ports that match the operational status you specify.

[-psu-id {<integer>|-}] - Power Supply Unit ID

Displays information only about the storage shelves with power supply units (PSU) that match the unit IDs you specify.

[-psu-location <text>,…​] - Power Supply Unit Location

Displays information only about the storage shelves with PSUs that are located at the specified location inside the shelf.

[-psu-type <text>,…​] - Power Supply Unit Type

Displays information only about the storage shelves with PSUs that match the PSU types you specify.

[-psu-part-number <text>,…​] - Power Supply Unit Part Number

Displays information only about the storage shelves with PSUs that match the PSU part number you specify.

[-psu-serial-number <text>,…​] - Power Supply Unit Serial Number

Displays information only about the storage shelves with PSUs that match the PSU serial numbers you specify.

[-psu-reset-capable {true|false}] - Power Supply Unit Reset Capability

Displays information only about the storage shelves with reset capable PSUs (true) or reset incapable PSUs (false).

[-psu-is-enabled {true|false}] - Power Supply Unit Enable/Disable Status

Displays information only about the storage shelves with PSUs that are enabled (true) or disabled (false).

[-psu-fw-version <text>,…​] - Power Supply Unit Firmware Version

Displays information only about the storage shelves with PSUs that have the firmware version you specify.

[-psu-op-status {unknown|normal|error|dc-over-voltage|dc-under-voltage|dc-over-current|over-temperature-error|failed|off|not-supported|not-installed}] - Operational Status

Displays information only about the storage shelves with PSUs that match the operational status you specify.

[-psu-power-rating {<integer>|-}] - Power Supply Power Ratings In Watts

Displays information only about the storage shelves with PSUs that match the power rating you specify.

[-psu-crest-factor {<integer>|-}] - Power Supply Crest Factor

Displays information only about the storage shelves with PSUs that match the crest factor value you specify.

[-psu-power-drawn {<integer>|-}] - Power Drawn From PSU In Watts

Displays information only about the storage shelves with PSUs that match the drawn power you specify.

[-temp-sensor-id {<integer>|-}] - Sensor Name

Displays information only about the storage shelves with temperature sensors that match the sensor IDs you specify.

[-temp-sensor-location <text>,…​] - Sensor Location

Displays information only about the storage shelves with temperature sensors that match the specified sensor locations inside the shelf.

[-temp-sensor-reading {<integer>|-}] - Temperature Reading

Displays information only about the storage shelves with temperature sensors that match the temperature reading you specify.

[-temp-is-ambient {true|false}] - Temperature Reading at Ambient Value

Displays information only about the storage shelves with temperature sensors whose current temperature reading is ambient (true) or not (false).

[-temp-high-critical-threshold {<integer>|-}] - High Critical Threshold

Displays information only about the storage shelves with temperature sensors that match the high critical threshold you specify.

[-temp-high-warning-threshold {<integer>|-}] - High Warning Threshold

Displays information only about the storage shelves with temperature sensors that match the high warning threshold you specify.

[-temp-low-warning-threshold {<integer>|-}] - Low Warning Threshold

Displays information only about the storage shelves with temperature sensors that match the low warning threshold you specify.

[-temp-low-critical-threshold {<integer>|-}] - Low Critical Threshold

Displays information only about the storage shelves with temperature sensors that match the low critical threshold you specify.

[-temp-op-status {unknown|normal|under-temperature|over-temperature|error|not-supported|not-installed}] - Operational Status

Displays information only about the storage shelves with temperature sensors that match the operational status you specify.

[-voltage-sensor-id {<integer>|-}] - Voltage Sensor ID

Displays information only about the storage shelves with voltage sens- ors that match the sensor IDs you specify.

[-voltage-sensor-location <text>,…​] - Voltage Sensor Location

Displays information only about the storage shelves with voltage sens- ors that match the specified sensor locations inside the shelf.

[-voltage-sensor-reading <text>,…​] - Voltage Current Reading

Displays information only about the storage shelves with voltage sens- ors that match the voltage reading you specify.

[-voltage-op-status {unknown|normal|over-voltage-critical|under-voltage-critical|not-supported|not-installed|not-recoverable}] - Operational Status

Displays information only about the storage shelves with voltage sens- ors that match the operational status you specify.

[-nsm-port-module-id {A|B}] - Port Module ID

Displays information only about the storage shelves with PCIe Ports from the specified module.

[-nsm-port-id <integer>,…​] - Port ID

Displays information only about the storage shelves with PCIe Ports that match the specified ID.

[-nsm-port-type {cpu|disk|cx5|ethernet}] - Port Type

Displays information only about the storage shelves with PCIe Ports that match the specified type.

[-nsm-port-state {ok|off-link-disabled|off-dll-link|link-down|no-drive}] - Port State

Displays information only about the storage shelves with PCIe Ports that match the specified state.

[-nsm-port-bay <integer>,…​] - Port Bay

Displays information only about the storage shelves with PCIe Ports that match the specified bay.

[-nsm-port-disk-id <integer>,…​] - Port Disk ID

Displays information only about the storage shelves with PCIe Ports that match the specified disk ID.

[-nsm-port-is-installed {true|false}] - Port Is Disk Installed

Displays information only about the storage shelves with PCIe Ports that have a disk installed.

[-nsm-port-is-error {true|false}] - Port Has Error

Displays information only about the storage shelves with PCIe Ports that have errors.

[-nsm-port-speed {2.5|5.0|8.0}] - Port Speed

Displays information only about the storage shelves with PCIe Ports that match the specified speed.

[-nsm-port-speed-max {2.5|5.0|8.0}] - Max Port Speed

Displays information only about the storage shelves with PCIe Ports that match the specified maximum speed.

[-nsm-port-lane-width <integer>,…​] - Port Lane Width

Displays information only about the storage shelves with PCIe Ports that match the specified lane width.

[-nsm-port-lane-width-max <integer>,…​] - Max Port Lane Width

Displays information only about the storage shelves with PCIe Ports that match the specified maximum lane width.

[-dimm-module-id {A|B}] - DIMM Module ID

Displays information only about the storage shelves with DIMMs from the specified module.

[-dimm-id <integer>,…​] - DIMM ID

Displays information only about the storage shelves with DIMMs that match the specified ID.

[-dimm-serial-number <text>,…​] - DIMM Serial Number

Displays information only about the storage shelves with DIMMs that match the specified serial number.

[-dimm-part-number <text>,…​] - DIMM Part Number

Displays information only about the storage shelves with DIMMs that match the specified part number.

[-dimm-vendor <text>,…​] - DIMM Vendor

Displays information only about the storage shelves with DIMMs that match the specified vendor.

[-dimm-type <text>,…​] - DIMM Type

Displays information only about the storage shelves with DIMMs that match the specified type.

[-dimm-size <text>,…​] - DIMM Size

Displays information only about the storage shelves with DIMMs that match the specified size.

[-dimm-speed <text>,…​] - DIMM Speed

Displays information only about the storage shelves with DIMMs that match the specified speed.

[-dimm-location <text>,…​] - DIMM Location

Displays information only about the storage shelves with DIMMs that match the specified location.

[-dimm-op-status {unknown|normal|error|not-supported|not-installed}] - DIMM Operational Status

Displays information only about the storage shelves with DIMMs that match the specified operational status.

[-boot-device-module-id {A|B}] - Boot Device Module ID

Displays information only about the storage shelves with boot devices from the specified module.

[-boot-device-id <integer>,…​] - Boot Device ID

Displays information only about the storage shelves with boot devices that match the specified ID.

[-boot-device-serial-number <text>,…​] - Boot Device Serial Number

Displays information only about the storage shelves with boot devices that match the specified serial number.

[-boot-device-part-number <text>,…​] - Boot Device Part Number

Displays information only about the storage shelves with boot devices that match the specified part number.

[-boot-device-vendor <text>,…​] - Boot Device Vendor

Displays information only about the storage shelves with boot devices that match the specified vendor.

[-boot-device-type <text>,…​] - Boot Device Type

Displays information only about the storage shelves with boot devices that match the specified type.

[-boot-device-size <text>,…​] - Boot Device Size

Displays information only about the storage shelves with boot devices that match the specified size.

[-boot-device-op-status {unknown|normal|error|not-supported|not-installed}] - Boot Device Operational Status

Displays information only about the storage shelves with boot devices that match the specified operational status.

[-coin-battery-module-id {A|B}] - Coin Battery Module ID

Displays information only about the storage shelves with coin batteries from the specified module.

[-coin-battery-id <integer>,…​] - Coin Battery ID

Displays information only about the storage shelves with coin batteries that match the specified ID.

[-coin-battery-voltage <integer>,…​] - Coin Battery Voltage (mV)

Displays information only about the storage shelves with coin batteries that match the specified voltage.

[-coin-battery-op-status {unknown|normal|error|low|high|not-supported|not-installed}] - Coin Battery Operational Status

Displays information only about the storage shelves with coin batteries that match the specified operational status.

[-error-type {Unknown|ACPP|Bootdevice|Coinbattery|Configuration|Current|Dimm|Expander|Fan|Module|PCM|Power|Temperature|Voltage}] - Error Type

Displays information only about the storage shelves with errors that match the error type you specify.

[-error-severity {unknown|notice|warning|error|critical}] - Error Severity

Displays information only about the storage shelves with errors that match the error severity you specify.

Examples

The following example displays information about all storage shelves:

cluster1::> storage shelf show
Module  Operational
           Shelf Name  Shelf ID  Serial Number    Model        Type    Status
    -----------------  --------  ---------------  -----------  ------  -----------
                  1.1         1  6000832415       DS2246       IOM6    Critical
                  1.2         2  6000647652       DS2246       IOM6    Normal
                  1.3         3  6000003844       DS2246       IOM6    Normal
                  1.4         4  SHJ000000013A9E  DS4246       IOM6    Normal
                  1.5         5  SHJ000000013A84  DS4246       IOM6    Normal
                  1.6         6  6000005555       DS2246       IOM6    Normal
    6 entries were displayed.
cluster1::>

The following example displays expanded information about a storage shelf named 1.2:

cluster1::> storage shelf show -shelf 1.2 -instance
Shelf Name: 1.2
                 Stack ID: 1
                 Shelf ID: 2
                Shelf UID: 50:0a:09:80:01:b9:75:41
            Serial Number: 6000647652
              Module Type: IOM6
                    Model: DS2246
             Shelf Vendor: FUJITSU
               Disk Count: 12
          Connection Type: SAS
              Shelf State: Online
                   Status: Normal
Modules:                                          Module is
                                     Monitor   Is     Reporting FW Update             Latest   Swap Operational Module
     ID Part No.     ES Serial No.   is Active Master Element   Progress      FW Rev. FW Rev. Count Status      Location
    --- ------------ --------------- --------- ------ --------- ------------- ------- ------- ----- ----------- --------------
      a 111-00190+A0 8006437891      true      false  false     not-available 0191    -           0 normal      rear of the shelf at the top left
      b 111-00190+A0 8006435180      true      true   true      not-available 0191    -           0 normal      rear of the shelf at the top right
Paths:
                                                                                                                 Speed
    Controller         Initiator Initiator Side Switch Port Target Side Switch Port    Target Port        TPGN    Gb/s I/O KB/s    IOPS
    ------------------ --------- -------------------------- -------------------------- ------------------ ------ ----- -------- -------
    stsw-8020-01       0a        -                          -                          -                  -          -        -       -
    stsw-8020-01       2b        -                          -                          -                  -          -        -       -
    stsw-8020-02       0a        -                          -                          -                  -          -        -       -
    stsw-8020-02       2b        -                          -                          -                  -          -        -       -
Power Supply Units:
                                                         Crest  Power   Reset   PSU              Operational
     ID Type Part#        Serial#         Power Rating   Factor Drawn   Capable Enabled Firmware Status           PSU Location
    --- ---- ------------ --------------- -------------- ------ ------- ------- ------- -------- ---------------- ------------------------
      1 9C   114-00065+A1 XXT131052637    -              -      -       false   true    020F     normal           rear of the shelf at the bottom left
      2 9C   114-00065+A1 XXT131052551    -              -      -       false   true    020F     normal           rear of the shelf at the bottom right
Voltage Sensors:
        Voltage Operational
     ID     (V) Status                 Sensor Location
    --- ------- ---------------------- ------------------------
      1    5.70 normal                 rear of the shelf on the lower left power supply
      2  12.300 normal                 rear of the shelf on the lower left power supply
      3    5.70 normal                 rear of the shelf on the lower right power supply
      4  12.180 normal                 rear of the shelf on the lower right power supply
Current Sensors:
        Current Operational
     ID    (mA) Status                 Sensor Location
    --- ------- ---------------------- ------------------------
      1       0 normal                 rear of the shelf on the lower left power supply
      2       0 normal                 rear of the shelf on the lower left power supply
      3       0 normal                 rear of the shelf on the lower right power supply
      4       0 normal                 rear of the shelf on the lower right power supply
Fans:
         Speed Operational
     ID  (RPM) Status                  Fan Location
    --- ------ ----------------------- ----------------------
      1   3000 normal                  rear of the shelf on the lower left power supply
      2   2970 normal                  rear of the shelf on the lower left power supply
      3   3000 normal                  rear of the shelf on the lower right power supply
      4   2970 normal                  rear of the shelf on the lower right power supply
Temperature:
                     -- Thresholds °C --
        Temp Is       Low  Low High High Operational
     ID   °C Ambient Crit Warn Crit Warn Status             Sensor Location
    --- ---- ------- ---- ---- ---- ---- ------------------ --------------------------------
      1   23 true       0    5   42   40 normal             front of the shelf on the left, on the OPS panel
      2   26 false      5   10   55   50 normal             inside of the shelf on the midplane
      3   24 false      5   10   55   50 normal             rear of the shelf on the lower left power supply
      4   39 false      5   10   70   65 normal             rear of the shelf on the lower left power supply
      5   25 false      5   10   55   50 normal             rear of the shelf on the lower right power supply
      6   36 false      5   10   70   65 normal             rear of the shelf on the lower right power supply
      7   25 false      5   10   60   55 normal             rear of the shelf at the top left, on shelf module A
      8   26 false      5   10   60   55 normal             rear of the shelf at the top right, on shelf module B
SAS Ports:
                                          -- Port Speeds Gb/s -- Power  Port
    Phy # IOM Port Type WWPN              Operational Negotiated Status Status
    ----- --- --------- ----------------- ----------- ---------- ------ -----------
        0  A  Square    500a098004b063b0          6.0          - -      Enabled
        1  A  Square    500a098004b063b0          6.0          - -      Enabled
        2  A  Square    500a098004b063b0          6.0          - -      Enabled
        3  A  Square    500a098004b063b0          6.0          - -      Enabled
        4  A  Circle    500a09800569f03f          6.0          - -      Enabled
        5  A  Circle    500a09800569f03f          6.0          - -      Enabled
        6  A  Circle    500a09800569f03f          6.0          - -      Enabled
        7  A  Circle    500a09800569f03f          6.0          - -      Enabled
        8  A  Disk      500605ba00c1cb8d          6.0        6.0 on     Enabled
        9  A  Disk      500605ba00c1ea8d          6.0        6.0 on     Enabled
       10  A  Disk      500605ba00c1d111          6.0        6.0 on     Enabled
       11  A  Disk      500605ba00c1bc49          6.0        6.0 on     Enabled
       12  A  Disk      500605ba00c1cdfd          6.0        6.0 on     Enabled
       13  A  Disk      500605ba00c1c531          6.0        6.0 on     Enabled
       14  A  Disk      500605ba00c1eb05          6.0        6.0 on     Enabled
       15  A  Disk      500605ba00c1ec29          6.0        6.0 on     Enabled
       16  A  Disk      500605ba00c1bc29          6.0        6.0 on     Enabled
       17  A  Disk      500605ba00c1c471          6.0        6.0 on     Enabled
       18  A  Disk      500605ba00c039a9          6.0        6.0 on     Enabled
       19  A  Disk      500605ba00c1c4dd          6.0        6.0 on     Enabled
       20  A  Disk      -                           -          - -      Empty
       21  A  Disk      -                           -          - -      Empty
       22  A  Disk      -                           -          - -      Empty
       23  A  Disk      -                           -          - -      Empty
       24  A  Disk      -                           -          - -      Empty
       25  A  Disk      -                           -          - -      Empty
       26  A  Disk      -                           -          - -      Empty
       27  A  Disk      -                           -          - -      Empty
       28  A  Disk      -                           -          - -      Empty
       29  A  Disk      -                           -          - -      Empty
       30  A  Disk      -                           -          - -      Empty
       31  A  Disk      -                           -          - -      Empty
       32  A  SIL       -                           -          - -      Disabled
       33  A  SIL       -                           -          - -      Disabled
       34  A  SIL       -                           -          - -      Disabled
       35  A  SIL       -                           -          - -      Disabled
        0  B  Square    500a098004af9e30          6.0          - -      Enabled
        1  B  Square    500a098004af9e30          6.0          - -      Enabled
        2  B  Square    500a098004af9e30          6.0          - -      Enabled
        3  B  Square    500a098004af9e30          6.0          - -      Enabled
        4  B  Circle    500a098005688dbf          6.0          - -      Enabled
        5  B  Circle    500a098005688dbf          6.0          - -      Enabled
        6  B  Circle    500a098005688dbf          6.0          - -      Enabled
        7  B  Circle    500a098005688dbf          6.0          - -      Enabled
        8  B  Disk      500605ba00c1cb8e          6.0        6.0 on     Enabled
        9  B  Disk      500605ba00c1ea8e          6.0        6.0 on     Enabled
       10  B  Disk      500605ba00c1d112          6.0        6.0 on     Enabled
       11  B  Disk      500605ba00c1bc4a          6.0        6.0 on     Enabled
       12  B  Disk      500605ba00c1cdfe          6.0        6.0 on     Enabled
       13  B  Disk      500605ba00c1c532          6.0        6.0 on     Enabled
       14  B  Disk      500605ba00c1eb06          6.0        6.0 on     Enabled
       15  B  Disk      500605ba00c1ec2a          6.0        6.0 on     Enabled
       16  B  Disk      500605ba00c1bc2a          6.0        6.0 on     Enabled
       17  B  Disk      500605ba00c1c472          6.0        6.0 on     Enabled
       18  B  Disk      500605ba00c039aa          6.0        6.0 on     Enabled
       19  B  Disk      500605ba00c1c4de          6.0        6.0 on     Enabled
       20  B  Disk      -                           -          - -      Empty
       21  B  Disk      -                           -          - -      Empty
       22  B  Disk      -                           -          - -      Empty
       23  B  Disk      -                           -          - -      Empty
       24  B  Disk      -                           -          - -      Empty
       25  B  Disk      -                           -          - -      Empty
       26  B  Disk      -                           -          - -      Empty
       27  B  Disk      -                           -          - -      Empty
       28  B  Disk      -                           -          - -      Empty
       29  B  Disk      -                           -          - -      Empty
       30  B  Disk      -                           -          - -      Empty
       31  B  Disk      -                           -          - -      Empty
       32  B  SIL       -                           -          - -      Disabled
       33  B  SIL       -                           -          - -      Disabled
       34  B  SIL       -                           -          - -      Disabled
       35  B  SIL       -                           -          - -      Disabled
FC Ports:
                  Port
     ID Port Type Status
    --- --------- -----------
      - -         -
Bays:
Has               Operational
     ID Disk  Bay Type    Status
    --- ----- ----------- -----------
      0 true  single-disk normal
      1 true  single-disk normal
      2 true  single-disk normal
      3 true  single-disk normal
      4 true  single-disk normal
      5 true  single-disk normal
      6 true  single-disk normal
      7 true  single-disk normal
      8 true  single-disk normal
      9 true  single-disk normal
     10 true  single-disk normal
     11 true  single-disk normal
     12 false single-disk normal
     13 false single-disk normal
     14 false single-disk normal
     15 false single-disk normal
     16 false single-disk normal
     17 false single-disk normal
     18 false single-disk normal
     19 false single-disk normal
     20 false single-disk normal
     21 false single-disk normal
     22 false single-disk normal
     23 false single-disk normal
cluster1::>

The following example displays information about the power supplies, voltage sensors and current sensors of the storage shelf 1.1:

cluster1::> storage shelf show -shelf 1.1 -power
Shelf Name: 1.1
                 Stack ID: 1
                 Shelf ID: 1
                Shelf UID: 50:0a:09:80:01:cb:d6:84
            Serial Number: 6000832415
              Module Type: IOM6
                    Model: DS2246
             Shelf Vendor: FUJITSU
               Disk Count: 12
          Connection Type: SAS
              Shelf State: Online
                   Status: Normal
Power Supply Units:
                                                         Crest  Power   Reset   PSU              Operational
     ID Type Part#        Serial#         Power Rating   Factor Drawn   Capable Enabled Firmware Status
    --- ---- ------------ --------------- -------------- ------ ------- ------- ------- -------- ---------------------
      1 9C   114-00065+A1 XXT132835072    -              -      -       false   true    020F     normal
      2 9C   114-00065+A1 XXT132835073    -              -      -       false   true    020F     normal
Voltage Sensors:
        Voltage Operational
     ID     (V) Status
    --- ------- ----------------------
      1    5.70 normal
      2  12.180 normal
      3    5.70 normal
      4  12.300 normal
Current Sensors:
        Current Operational
     ID    (mA) Status
    --- ------- ----------------------
      1       0 normal
      2       0 normal
      3    3900 normal
      4       0 normal
Errors:
    ------
    Critical condition is detected in storage shelf power supply unit "1". The unit might fail.
    Critical over temperature failure for temperature sensor "1". Current temperature: "75" C ("167" F).
cluster1::>

The following example displays information about the cooling elements and temperature sensors inside the storage shelf 1.2:

cluster1::> storage shelf show -shelf 1.2 -cooling
Shelf Name: 1.2
                 Stack ID: 1
                 Shelf ID: 2
                Shelf UID: 50:0a:09:80:01:b9:75:41
            Serial Number: 6000647652
              Module Type: IOM6
                    Model: DS2246
             Shelf Vendor: FUJITSU
               Disk Count: 12
          Connection Type: SAS
              Shelf State: Online
                   Status: Normal
Fans:
       Speed Operational
    ID (RPM) Status
    -- ----- -------------
     1  3000 normal
     2  3000 normal
     3  3000 normal
     4  2970 normal
Temperature:
                 -- Thresholds °C --
        Temp Is       Low  Low High High Operational
     ID   °C Ambient Crit Warn Crit Warn Status
    --- ---- ------- ---- ---- ---- ---- ------------------
      1   23 true       0    5   42   40 normal
      2   26 false      5   10   55   50 normal
      3   24 false      5   10   55   50 normal
      4   39 false      5   10   70   65 normal
      5   25 false      5   10   55   50 normal
      6   36 false      5   10   70   65 normal
      7   25 false      5   10   60   55 normal
      8   27 false      5   10   60   55 normal
Errors:
    ------
    -
cluster1::>

The following example displays information about the connectivity from the node to the storage shelf 1.2:

cluster1::> storage shelf show -shelf 1.2 -connectivity
               Shelf Name: 1.2
                 Stack ID: 1
                 Shelf ID: 2
                Shelf UID: 50:0a:09:80:01:b9:75:41
            Serial Number: 6000647652
              Module Type: IOM6
                    Model: DS2246
             Shelf Vendor: FUJITSU
               Disk Count: 12
          Connection Type: SAS
              Shelf State: Online
                   Status: Normal
Paths:
Controller         Initiator Initiator Side Switch Port Target Side Switch Port    Target Port        TPGN
    ------------------ --------- -------------------------- -------------------------- ------------------ ------
    stsw-8020-01       0a        -                          -                          -                  -
    stsw-8020-01       2b        -                          -                          -                  -
    stsw-8020-02       0a        -                          -                          -                  -
    stsw-8020-02       2b        -                          -                          -                  -
Errors:
    ------
    -
cluster1::>

The following example displays information about the disk bays of the storage shelf 1.2:

cluster1::> storage shelf show -shelf 1.2 -bay
Shelf Name: 1.2
                     Stack ID: 1
                     Shelf ID: 2
                    Shelf UID: 50:0a:09:80:01:b9:75:41
                Serial Number: 6000647652
                  Module Type: IOM6
                        Model: DS2246
                 Shelf Vendor: FUJITSU
                   Disk Count: 12
              Connection Type: SAS
                  Shelf State: Online
                       Status: Normal
Bays:
Has               Operational
     ID Disk  Bay Type    Status
    --- ----- ----------- -----------
      0 true  single-disk normal
      1 true  single-disk normal
      2 true  single-disk normal
      3 true  single-disk normal
      4 true  single-disk normal
      5 true  single-disk normal
      6 true  single-disk normal
      7 true  single-disk normal
      8 true  single-disk normal
      9 true  single-disk normal
     10 true  single-disk normal
     11 true  single-disk normal
     12 false single-disk normal
     13 false single-disk normal
     14 false single-disk normal
     15 false single-disk normal
     16 false single-disk normal
     17 false single-disk normal
     18 false single-disk normal
     19 false single-disk normal
     20 false single-disk normal
     21 false single-disk normal
     22 false single-disk normal
     23 false single-disk normal
Errors:
    ------
    -
cluster1::>

The following example displays information about the ports of the storage shelf 1.2:

cluster1::> storage shelf show -shelf 1.2 -port
Shelf Name: 1.2
                 Stack ID: 1
                 Shelf ID: 2
                Shelf UID: 50:0a:09:80:01:b9:75:41
            Serial Number: 6000647652
              Module Type: IOM6
                    Model: DS2246
             Shelf Vendor: FUJITSU
               Disk Count: 12
          Connection Type: SAS
              Shelf State: Online
                   Status: Normal
SAS Ports:
                                          -- Port Speeds Gb/s -- Power  Port
    Phy # IOM Port Type WWPN              Operational Negotiated Status Status
    ----- --- --------- ----------------- ----------- ---------- ------ -----------
        0  A  Square    500a098004b063b0          6.0          - -      Enabled
        1  A  Square    500a098004b063b0          6.0          - -      Enabled
        2  A  Square    500a098004b063b0          6.0          - -      Enabled
        3  A  Square    500a098004b063b0          6.0          - -      Enabled
        4  A  Circle    500a09800569f03f          6.0          - -      Enabled
        5  A  Circle    500a09800569f03f          6.0          - -      Enabled
        6  A  Circle    500a09800569f03f          6.0          - -      Enabled
        7  A  Circle    500a09800569f03f          6.0          - -      Enabled
        8  A  Disk      500605ba00c1cb8d          6.0        6.0 on     Enabled
        9  A  Disk      500605ba00c1ea8d          6.0        6.0 on     Enabled
       10  A  Disk      500605ba00c1d111          6.0        6.0 on     Enabled
       11  A  Disk      500605ba00c1bc49          6.0        6.0 on     Enabled
       12  A  Disk      500605ba00c1cdfd          6.0        6.0 on     Enabled
       13  A  Disk      500605ba00c1c531          6.0        6.0 on     Enabled
       14  A  Disk      500605ba00c1eb05          6.0        6.0 on     Enabled
       15  A  Disk      500605ba00c1ec29          6.0        6.0 on     Enabled
       16  A  Disk      500605ba00c1bc29          6.0        6.0 on     Enabled
       17  A  Disk      500605ba00c1c471          6.0        6.0 on     Enabled
       18  A  Disk      500605ba00c039a9          6.0        6.0 on     Enabled
       19  A  Disk      500605ba00c1c4dd          6.0        6.0 on     Enabled
       20  A  Disk      -                           -          - -      Empty
       21  A  Disk      -                           -          - -      Empty
       22  A  Disk      -                           -          - -      Empty
       23  A  Disk      -                           -          - -      Empty
       24  A  Disk      -                           -          - -      Empty
       25  A  Disk      -                           -          - -      Empty
       26  A  Disk      -                           -          - -      Empty
       27  A  Disk      -                           -          - -      Empty
       28  A  Disk      -                           -          - -      Empty
       29  A  Disk      -                           -          - -      Empty
       30  A  Disk      -                           -          - -      Empty
       31  A  Disk      -                           -          - -      Empty
       32  A  SIL       -                           -          - -      Disabled
       33  A  SIL       -                           -          - -      Disabled
       34  A  SIL       -                           -          - -      Disabled
       35  A  SIL       -                           -          - -      Disabled
        0  B  Square    500a098004af9e30          6.0          - -      Enabled
        1  B  Square    500a098004af9e30          6.0          - -      Enabled
        2  B  Square    500a098004af9e30          6.0          - -      Enabled
        3  B  Square    500a098004af9e30          6.0          - -      Enabled
        4  B  Circle    500a098005688dbf          6.0          - -      Enabled
        5  B  Circle    500a098005688dbf          6.0          - -      Enabled
        6  B  Circle    500a098005688dbf          6.0          - -      Enabled
        7  B  Circle    500a098005688dbf          6.0          - -      Enabled
        8  B  Disk      500605ba00c1cb8e          6.0        6.0 on     Enabled
        9  B  Disk      500605ba00c1ea8e          6.0        6.0 on     Enabled
       10  B  Disk      500605ba00c1d112          6.0        6.0 on     Enabled
       11  B  Disk      500605ba00c1bc4a          6.0        6.0 on     Enabled
       12  B  Disk      500605ba00c1cdfe          6.0        6.0 on     Enabled
       13  B  Disk      500605ba00c1c532          6.0        6.0 on     Enabled
       14  B  Disk      500605ba00c1eb06          6.0        6.0 on     Enabled
       15  B  Disk      500605ba00c1ec2a          6.0        6.0 on     Enabled
       16  B  Disk      500605ba00c1bc2a          6.0        6.0 on     Enabled
       17  B  Disk      500605ba00c1c472          6.0        6.0 on     Enabled
       18  B  Disk      500605ba00c039aa          6.0        6.0 on     Enabled
       19  B  Disk      500605ba00c1c4de          6.0        6.0 on     Enabled
       20  B  Disk      -                           -          - -      Empty
       21  B  Disk      -                           -          - -      Empty
       22  B  Disk      -                           -          - -      Empty
       23  B  Disk      -                           -          - -      Empty
       24  B  Disk      -                           -          - -      Empty
       25  B  Disk      -                           -          - -      Empty
       26  B  Disk      -                           -          - -      Empty
       27  B  Disk      -                           -          - -      Empty
       28  B  Disk      -                           -          - -      Empty
       29  B  Disk      -                           -          - -      Empty
       30  B  Disk      -                           -          - -      Empty
       31  B  Disk      -                           -          - -      Empty
       32  B  SIL       -                           -          - -      Disabled
       33  B  SIL       -                           -          - -      Disabled
       34  B  SIL       -                           -          - -      Disabled
       35  B  SIL       -                           -          - -      Disabled
FC Ports:
                  Port
     ID Port Type Status
    --- --------- -----------
      - -         -
Errors:
    ------
    -
cluster1::>

The following example displays error information about the storage shelves that have errors:

cluster1::> storage shelf show -errors
Shelf Name: 1.1
         Shelf UID: 50:0a:09:80:01:cb:d6:84
     Serial Number: 6000832415
Error Type          Description
    ------------------  ---------------------------
    Power               Critical condition is detected in storage shelf power supply unit "1". The unit might fail.
    Temperature         Critical over temperature failure for temperature sensor "1". Current temperature: "75" C ("167" F).
Top of Page