ONTAP 9.13.1 commands

volume efficiency inactive-data-compression modify

Modify volume inactive data compression configuration of a volume

Availability: This command is available to cluster and Vserver administrators at the advanced privilege level.

Description

The volume efficiency inactive-data-compression modify command is used to modify the state of inactive data compression on a volume.

Parameters

-vserver <vserver name> - Vserver Name

This specifies the Vserver of the volume.

-volume <volume name> - Volume Name

This specifies the volume on which the inactive data compression state should be modified.

[-progress <text>] - Progress

Progress of the scan.

[-status <text>] - Status

Operation on the scan succeeded or failed.

[-failure-reason <text>] - Failure Reason

If scan failed, the reason of the failure.

[-total-blocks <integer>] - Total Blocks to be Processed

Total number of blocks which must be processed by inactive data compression scanner.

[-total-processed <integer>] - Total Blocks Processed

Total number of blocks which are already processed by inactive data compression scanner.

[-percentage <percent>] - Progress

Scan progress in percentage.

[-is-enabled {true|false}] - State of Inactive Data Compression on the Volume

Enable or disable inactive data compression on the volume.

[-threshold-days <integer>] - Inactive data compression scan threshold days value

Threshold days value for inactive data compression scan.

[-threshold-days-min <integer>] - Inactive data compression scan threshold minimum allowed value.

Minimum allowed value in threshold days for inactive data compression scan.

[-threshold-days-max <integer>] - Inactive data compression scan threshold maximum allowed value.

Maximum allowed value in threshold days for inactive data compression scan.

[-read-history-window-size <integer>] - Time window(in days) for which client reads data is collected for tuning.

Client read history window.

[-tuning-enabled {true|false}] - State of auto-tuning of Inactive data compression scan on volume.

Auto-tuning state of inactive data compression scan.

[-compression-algorithm {lzopro|zstd}] - Inactive data compression algorithm

Inactive data compression algorithm.

Examples

The following example displays information for modifying the state of inactive data compression scan on volume "vol1":

cluster:::> volume efficiency inactive-data-compression modify -vserver vs1 -volume vol1 -is-scan-enabled true
Inactive data compression scan enabled on volume vol1 in Vserver vs1.
Top of Page