ONTAP 9.14.1 commands
storage shelf show
Display a list of storage shelves
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The storage shelf show
command displays information about all the storage shelves in the storage system. If no parameters are specified, the default command displays the following information about the storage shelves:
-
Shelf Name
-
Shelf ID
-
Serial Number
-
Model
-
Module Type
-
Status
To display detailed profile information about a single storage shelf, use the -shelf
parameter.
Parameters
- {
[-fields <fieldname>,…]
-
Displays the specified fields for all the storage shelves, in column style output.
- |
[-bay ]
-
Displays the following details about the disk bays in the storage shelf:
-
The unique positional identifier of the disk bay
-
Whether a disk drive is installed in the bay
-
Bay type
-
Operational status of the disk bay
-
- |
[-connectivity ]
-
Displays the following details about the connectivity from the node to the storage shelf:
-
Node name
-
Initiator side switch port
-
Target side switch port
-
World-wide port name
-
Target Port Group Number (TPGN)
-
- |
[-cooling ]
-
Displays the following details about the cooling elements and temperature sensors of the storage shelf:
-
Element ID of the cooling fan
-
The current speed of the cooling fan in revolutions per minute (rpm)
-
Operational status of the cooling fan
-
Sensor ID of the temperature sensor element
-
Temperature at the sensor in degrees Celsius
-
Whether the current temperature at the sensor is the ambient temperature
-
Low critical threshold value for the temperature sensor
-
Low warning threshold value for the temperature sensor
-
High critical threshold value for the temperature sensor
-
High warning threshold value for the temperature sensor
-
Operational status for the temperature sensor
-
- |
[-errors ]
-
Displays the following error status information about the storage shelves that have errors:
-
Error type
-
Error description
-
- |
[-module ]
-
Displays the following details about the I/O modules attached to the storage shelf:
-
Module ID
-
Module part number
-
Serial number of the Enclosure Services Controller Electronics element
-
Whether monitoring is enabled on this module
-
Whether this module is the SAS expander master module
-
Whether this module is the element reporting
-
Version of the firmware installed on the module
-
Latest firmware revision
-
Number of times, since the last boot, that this module has been swapped
-
Operational status of the module
-
- |
[-port ]
-
Displays the following details about the storage shelf ports:
-
Expander phy element identifier
-
SAS shelf port type
-
World-wide Port Name of the SAS port
-
Operational physical link rate of the SAS port in Gb/s
-
Negotiated physical link rate of the SAS port in Gb/s
-
Power status of the SAS port
-
Status of the SAS port
-
Fibre Channel shelf port ID
-
Fibre Channel shelf port type
-
Fibre Channel shelf port status
-
- |
[-power ]
-
Displays the following details about the power supplies, voltage sensors, and current sensors of the storage shelf:
-
Power Supply Unit (PSU) number
-
PSU type
-
PSU part number
-
PSU serial number
-
PSU power rating in watts
-
PSU crest factor
-
Power drawn from the PSU in watts
-
Whether the PSU can be reset via software control
-
Whether the auto power reset of the PSU is enabled
-
PSU firmware revision
-
Operational status of the PSU
-
Voltage sensor number
-
Voltage detected by the voltage sensor, in volts (V)
-
Operational status of the voltage sensor
-
Current sensor number
-
Current detected by the current sensor, in milliamps (mA)
-
Operational status of the current sensor
-
- |
[-instance ]
} -
Displays expanded information about all the storage shelves in the system.
[-shelf <text>]
- Shelf Name-
Displays information only about the storage shelves that match the names you specify.
[-node {<nodename>|local}]
- Node-
Displays information only about the storage shelves that are attached to the node you specify.
[-shelf-uid <text>]
- Shelf UID-
Displays information only about the storage shelf that matches the shelf UID you specify. Example: `50:05:0c:c0:02:10:64:26 `
[-stack-id {<integer>|-}]
- Stack ID-
Displays information only about the storage shelves that are attached to the stack that matches the stack ID you specify
[-shelf-id <text>]
- Shelf ID-
Displays information only about the storage shelves that match the shelf ID you specify.
[-module-type {unknown|atfcx|esh4|iom3|iom6|iom6e|iom12|iom12e|iom12f|nsm100|nsm8e|psm3e|iom12b|iom12g|iom12c}]
- Shelf Module Type-
Displays information only about the storage shelves that match the module-type you specify.
[-connection-type {unknown|fc|sas|nvme}]
- Shelf Connection Type-
Displays information only about the storage shelves that match the connection type you specify. Example: FC or SAS.
[-is-local-attach {true|false}]
- Is the Shelf Local to This Cluster?-
Displays information only about the storage shelves that are local (TRUE) or remote (FALSE) to this cluster.
[-product-id <text>]
- Shelf Product Identification-
Displays information only about the storage shelves that match the product ID you specify.
[-serial-number <text>]
- Shelf Serial Number-
Displays information only about the storage shelf that matches the serial number you specify.
[-disk-count {<integer>|-}]
- Disk Count-
Displays information only about the storage shelves that have the disk count you specify.
[-state {unknown|no-status|init-required|online|offline|missing}]
- Shelf State-
Displays information only about the storage shelves that are in the state you specify.
[-op-status {unknown|normal|warning|error|critical|standby-power}]
- Shelf Operational Status-
Displays information only about the storage shelves that are currently operating under the status condition you specify.
[-bay-id {<integer>|-}]
- Bay ID-
Displays information only about the storage shelves that have bays that match the bay ID you specify.
[-bay-type {unknown|single-disk|multi-lun}]
- Bay Type-
Displays information only about the storage shelves that have bays that match the type of bay you specify.
[-bay-has-disk {true|false}]
- Bay Has Disk-
Displays information only about the storage shelves that have bays with disk drives inserted in them (true) or empty bays (false).
[-bay-op-status {unknown|normal|error}]
- Bay Operational Status-
Displays information only about the storage shelves that have bays that match the operational state you specify.
[-controller {<nodename>|local}]
- Controller Name-
Displays information only about the storage shelves that are connected to the node you specify.
[-controller-uuid <text>,…]
- Controller UUID-
Displays information only about the storage shelves that are connected to the node UUID you specify.
[-initiator <text>,…]
- Initiator-
Displays information only about the storage shelves that are visible to the initiator you specify.
[-initiator-wwpn <text>,…]
- Initiator WWPN-
Displays information only about the storage shelves that are visible to the initiator WWPN you specify.
[-initiator-side-switch-port <text>,…]
- Initiator Side Switch Port-
Displays information only about the storage shelves that are visible to an initiator connected to the switch port you specify.
[-target-side-switch-port <text>,…]
- Target Side Switch Port-
Displays information only about the storage shelves visible on target ports identified by the switch port to which they are connected.
[-target-port <text>,…]
- Target Port-
Displays information only about the storage shelves visible on the specified target ports identified by their World-Wide Port Name (WWPN).
[-tpgn {<integer>|-}]
- Target Port Group Number-
Displays information only about the storage shelves that belong to the Target Port Group Name (TPGN) you specify.
[-port-speed {<integer>|-}]
- Port Speed-
Displays information only about the storage shelves with ports that match the port speed you specify.
[-io-kbps {<integer>|-}]
- Kbytes/sec on Storage Shelf-
Displays information only about the storage shelves visible to an initiator that has executed I/O at the throughput you specify.
[-iops {<integer>|-}]
- Number IOPS per Second on Storage Shelf-
Displays information only about the storage shelves visible to an initiator that has executed the number of IOPs you specify.
[-current-sensor-id {<integer>|-}]
- Current Sensor ID-
Displays information only about the storage shelves with current sensor that matches the current sensor ID you specify.
[-current-sensor-location <text>,…]
- Current Sensor Location-
Displays information only about the storage shelves with current sensors installed at the location you specify.
[-current-sensor-reading {<integer>|-}]
- Current Sensor Reading-
Displays information only about the storage shelves with current sensors that match the current reading you specify.
[-current-op-status {unknown|normal|over-current-critical|under-current-critical|not-supported|not-installed}]
- Operational Status-
Displays information only about the storage shelves with current sensors that match the operational status you specify.
[-fan-id {<integer>|-}]
- Fan ID-
Displays information only about the storage shelves with cooling fans that match the fan IDs you specify.
[-fan-location <text>,…]
- Fan Location-
Displays information only about the storage shelves with cooling fans installed.
[-fan-rpm {<integer>|-}]
- Fan Rotation Per Minute-
Displays information only about the storage shelves with cooling fans that match the rpm rate you specify.
[-fan-op-status {unknown|normal|off|error|not-supported|not-installed}]
- Fan Operational Status-
Displays information only about the storage shelves with cooling fans that match the operational status you specify.
[-module-id <text>,…]
- Module ID-
Displays information only about the storage shelves with an I/O module that matches the module ID you specify.
[-module-location <text>,…]
- Module Location-
Displays information only about the storage shelves with I/O modules in the specified shelf module slots.
[-module-part-number <text>,…]
- Module Part Number-
Displays information only about the storage shelves with I/O modules that match the module part numbers you specify.
[-is-sas-master-module {true|false}]
- Is SAS Expander Master Module?-
Displays information only about the storage shelves with a SAS master I/O module (true) or an I/O module that is not a SAS master (false). This parameter applies only to SAS shelves.
[-is-monitor-active {true|false}]
- Is Monitor Active?-
Displays information only about the storage shelves whose monitoring is enabled (true) or disabled (false).
[-enclosure-type <text>,…]
- Module Enclosure Type-
Displays information only about the storage shelves that match the enclosure types you specify.
[-es-serial-number <text>,…]
- ES Electronics Element Serial Number-
Displays information only about the storage shelves with I/O modules that match the electronics serial numbers you specify.
[-module-fru-id <text>,…]
- Field Replaceable Unit ID-
Displays information only about the storage shelves with I/O modules that match the field replaceable unit (FRU) IDs you specify.
[-module-is-reporting-element {true|false}]
- Is Reporting Element?-
Displays information only about the storage shelves with element reporting I/O modules (true) or not (false).
[-module-fw-revision <text>,…]
- Firmware Revision-
Displays information only about the storage shelves with I/O modules that match the firmware revision you specify.
[-module-latest-fw-revision <text>,…]
- Latest Firmware Revision-
Displays information only about the storage shelves with I/O modules that match the latest firmware revision you specify.
[-module-fw-progress {not-available|ready|in-progress|failed}]
- Module Firmware Progress-
Displays information only about the storage shelves with I/O modules that match the specified firmware update progress.
[-module-swap-count {<integer>|-}]
- Module Swap Count-
Displays information only about the storage shelves whose I/O modules have been swapped the specified number of times.
[-module-op-status {unknown|normal|warning|error|not-installed}]
- Module Operational Status-
Displays information only about the storage shelves with I/O modules that match the operational status you specify.
[-sas-port-id <text>,…]
- Port ID-
Displays information only about the storage shelves with SAS Ports that match the port IDs you specify.
[-sas-port-type {unknown|circle|square|sil|disk|in|out|unused|host|dcm|aux1|aux2|hi_ho|a_to_b|b_to_a}]
- Port Type-
Displays information only about the storage shelves with SAS Ports that match the SAS port type you specify.
[-sas-port-wwpn <text>,…]
- Port World Wide Port Name-
Displays information only about the storage shelves with SAS Ports that match the World-Wide Port Names you specify.
[-sas-port-speed <text>,…]
- Port Speed-
Displays information only about the storage shelves with SAS Ports that match the port speed you specify.
[-sas-negotiated-port-speed <text>,…]
- Negotiated Port Speed-
Displays information only about the storage shelves with SAS Ports that match the negotiated port speed you specify.
[-sas-port-power-status <text>,…]
- Port Power Status-
Displays information only about the storage shelves with SAS Ports that match the power status you specify.
[-sas-port-op-status {error|normal|off|unknown|byp-bad-term|bad-zone-recovery|byp_clk_thr|byp_comma_los|byp_crc_brst_thr|byp_data_timeout|byp_drv_fault|byp_drv_pcycle|byp_drv_pwr|byp_drv_self|byp_gen|byp_init|byp_lip_brst_thr|byp_lip_f8|byp_lip_rate_thr|byp_lipf7|byp_ltbi|byp_man|byp_no_drive|byp_osc|byp_other_thr|byp_rec_los|byp_rport|byp_stall_thr|byp_wrd_brst_thr|byp_wrd_rate_thr|byp_xmit_fault|diag_transmit|inserted|loopback|status_unknown|warn_high_clk_delta|warn_high_crc_rate|warn_high_lip|warn_high_wrd_rate|term|phy_dis_clk_fault|phy_dis_crc_err|phy_dis_crc_err_burst|phy_dis_disparity|phy_dis_disparity_burst|phy_dis_emulate_reserve|phy_dis_inval_dword|phy_dis_inval_dword_burst|phy_dis_loss_dword|phy_dis_loss_dword_burst|phy_dis_man_smp|phy_dis_manual|phy_dis_mirrored|empty|phy_dis_phy_change|phy_dis_phy_change_burst|phy_dis_phy_reset|phy_dis_phy_reset_burst|phy_dis_phy_unused|phy_ena|phy_ena_not_attach|phy_ena_unknown|phy_unknown|phy_dis_illegal}]
- Port Operational Status-
Displays information only about the storage shelves with SAS Ports that match the operational status you specify.
[-sas-port-module-id {A|B}]
- Port Module ID-
Displays information only about the storage shelves with SAS Ports that match the module ID you specify.
[-fc-port-id <text>,…]
- Fibre Channel Port ID-
Displays information only about the storage shelves with FC Ports that match the port IDs you specify.
[-fc-port-mode {unknown|circle|square|sil|disk|in|out|unused|host|dcm|aux1|aux2|hi_ho|a_to_b|b_to_a}]
- Fibre Channel Port Mode-
Displays information only about the storage shelves with FC Ports that match the port modes you specify.
[-fc-port-op-status {error|normal|off|unknown|byp-bad-term|bad-zone-recovery|byp_clk_thr|byp_comma_los|byp_crc_brst_thr|byp_data_timeout|byp_drv_fault|byp_drv_pcycle|byp_drv_pwr|byp_drv_self|byp_gen|byp_init|byp_lip_brst_thr|byp_lip_f8|byp_lip_rate_thr|byp_lipf7|byp_ltbi|byp_man|byp_no_drive|byp_osc|byp_other_thr|byp_rec_los|byp_rport|byp_stall_thr|byp_wrd_brst_thr|byp_wrd_rate_thr|byp_xmit_fault|diag_transmit|inserted|loopback|status_unknown|warn_high_clk_delta|warn_high_crc_rate|warn_high_lip|warn_high_wrd_rate|term|phy_dis_clk_fault|phy_dis_crc_err|phy_dis_crc_err_burst|phy_dis_disparity|phy_dis_disparity_burst|phy_dis_emulate_reserve|phy_dis_inval_dword|phy_dis_inval_dword_burst|phy_dis_loss_dword|phy_dis_loss_dword_burst|phy_dis_man_smp|phy_dis_manual|phy_dis_mirrored|empty|phy_dis_phy_change|phy_dis_phy_change_burst|phy_dis_phy_reset|phy_dis_phy_reset_burst|phy_dis_phy_unused|phy_ena|phy_ena_not_attach|phy_ena_unknown|phy_unknown|phy_dis_illegal}]
- Fibre Channel Port Operational Status-
Displays information only about the storage shelves with FC Ports that match the operational status you specify.
[-psu-id {<integer>|-}]
- Power Supply Unit ID-
Displays information only about the storage shelves with power supply units (PSU) that match the unit IDs you specify.
[-psu-location <text>,…]
- Power Supply Unit Location-
Displays information only about the storage shelves with PSUs that are located at the specified location inside the shelf.
[-psu-type <text>,…]
- Power Supply Unit Type-
Displays information only about the storage shelves with PSUs that match the PSU types you specify.
[-psu-part-number <text>,…]
- Power Supply Unit Part Number-
Displays information only about the storage shelves with PSUs that match the PSU part number you specify.
[-psu-serial-number <text>,…]
- Power Supply Unit Serial Number-
Displays information only about the storage shelves with PSUs that match the PSU serial numbers you specify.
[-psu-reset-capable {true|false}]
- Power Supply Unit Reset Capability-
Displays information only about the storage shelves with reset capable PSUs (true) or reset incapable PSUs (false).
[-psu-is-enabled {true|false}]
- Power Supply Unit Enable/Disable Status-
Displays information only about the storage shelves with PSUs that are enabled (true) or disabled (false).
[-psu-fw-version <text>,…]
- Power Supply Unit Firmware Version-
Displays information only about the storage shelves with PSUs that have the firmware version you specify.
[-psu-op-status {unknown|normal|error|dc-over-voltage|dc-under-voltage|dc-over-current|over-temperature-error|failed|off|not-supported|not-installed}]
- Operational Status-
Displays information only about the storage shelves with PSUs that match the operational status you specify.
[-psu-power-rating {<integer>|-}]
- Power Supply Power Ratings In Watts-
Displays information only about the storage shelves with PSUs that match the power rating you specify.
[-psu-crest-factor {<integer>|-}]
- Power Supply Crest Factor-
Displays information only about the storage shelves with PSUs that match the crest factor value you specify.
[-psu-power-drawn {<integer>|-}]
- Power Drawn From PSU In Watts-
Displays information only about the storage shelves with PSUs that match the drawn power you specify.
[-temp-sensor-id {<integer>|-}]
- Sensor Name-
Displays information only about the storage shelves with temperature sensors that match the sensor IDs you specify.
[-temp-sensor-location <text>,…]
- Sensor Location-
Displays information only about the storage shelves with temperature sensors that match the specified sensor locations inside the shelf.
[-temp-sensor-reading {<integer>|-}]
- Temperature Reading-
Displays information only about the storage shelves with temperature sensors that match the temperature reading you specify.
[-temp-is-ambient {true|false}]
- Temperature Reading at Ambient Value-
Displays information only about the storage shelves with temperature sensors whose current temperature reading is ambient (true) or not (false).
[-temp-high-critical-threshold {<integer>|-}]
- High Critical Threshold-
Displays information only about the storage shelves with temperature sensors that match the high critical threshold you specify.
[-temp-high-warning-threshold {<integer>|-}]
- High Warning Threshold-
Displays information only about the storage shelves with temperature sensors that match the high warning threshold you specify.
[-temp-low-warning-threshold {<integer>|-}]
- Low Warning Threshold-
Displays information only about the storage shelves with temperature sensors that match the low warning threshold you specify.
[-temp-low-critical-threshold {<integer>|-}]
- Low Critical Threshold-
Displays information only about the storage shelves with temperature sensors that match the low critical threshold you specify.
[-temp-op-status {unknown|normal|under-temperature|over-temperature|error|not-supported|not-installed}]
- Operational Status-
Displays information only about the storage shelves with temperature sensors that match the operational status you specify.
[-voltage-sensor-id {<integer>|-}]
- Voltage Sensor ID-
Displays information only about the storage shelves with voltage sens- ors that match the sensor IDs you specify.
[-voltage-sensor-location <text>,…]
- Voltage Sensor Location-
Displays information only about the storage shelves with voltage sens- ors that match the specified sensor locations inside the shelf.
[-voltage-sensor-reading <text>,…]
- Voltage Current Reading-
Displays information only about the storage shelves with voltage sens- ors that match the voltage reading you specify.
[-voltage-op-status {unknown|normal|over-voltage-critical|under-voltage-critical|not-supported|not-installed|not-recoverable}]
- Operational Status-
Displays information only about the storage shelves with voltage sens- ors that match the operational status you specify.
[-nsm-port-module-id {A|B}]
- Port Module ID-
Displays information only about the storage shelves with PCIe Ports from the specified module.
[-nsm-port-id <integer>,…]
- Port ID-
Displays information only about the storage shelves with PCIe Ports that match the specified ID.
[-nsm-port-type {cpu|disk|cx5|ethernet}]
- Port Type-
Displays information only about the storage shelves with PCIe Ports that match the specified type.
[-nsm-port-state {ok|off-link-disabled|off-dll-link|link-down|no-drive}]
- Port State-
Displays information only about the storage shelves with PCIe Ports that match the specified state.
[-nsm-port-bay <integer>,…]
- Port Bay-
Displays information only about the storage shelves with PCIe Ports that match the specified bay.
[-nsm-port-disk-id <integer>,…]
- Port Disk ID-
Displays information only about the storage shelves with PCIe Ports that match the specified disk ID.
[-nsm-port-is-installed {true|false}]
- Port Is Disk Installed-
Displays information only about the storage shelves with PCIe Ports that have a disk installed.
[-nsm-port-is-error {true|false}]
- Port Has Error-
Displays information only about the storage shelves with PCIe Ports that have errors.
[-nsm-port-speed {2.5|5.0|8.0}]
- Port Speed-
Displays information only about the storage shelves with PCIe Ports that match the specified speed.
[-nsm-port-speed-max {2.5|5.0|8.0}]
- Max Port Speed-
Displays information only about the storage shelves with PCIe Ports that match the specified maximum speed.
[-nsm-port-lane-width <integer>,…]
- Port Lane Width-
Displays information only about the storage shelves with PCIe Ports that match the specified lane width.
[-nsm-port-lane-width-max <integer>,…]
- Max Port Lane Width-
Displays information only about the storage shelves with PCIe Ports that match the specified maximum lane width.
[-dimm-module-id {A|B}]
- DIMM Module ID-
Displays information only about the storage shelves with DIMMs from the specified module.
[-dimm-id <integer>,…]
- DIMM ID-
Displays information only about the storage shelves with DIMMs that match the specified ID.
[-dimm-serial-number <text>,…]
- DIMM Serial Number-
Displays information only about the storage shelves with DIMMs that match the specified serial number.
[-dimm-part-number <text>,…]
- DIMM Part Number-
Displays information only about the storage shelves with DIMMs that match the specified part number.
[-dimm-vendor <text>,…]
- DIMM Vendor-
Displays information only about the storage shelves with DIMMs that match the specified vendor.
[-dimm-type <text>,…]
- DIMM Type-
Displays information only about the storage shelves with DIMMs that match the specified type.
[-dimm-size <text>,…]
- DIMM Size-
Displays information only about the storage shelves with DIMMs that match the specified size.
[-dimm-speed <text>,…]
- DIMM Speed-
Displays information only about the storage shelves with DIMMs that match the specified speed.
[-dimm-location <text>,…]
- DIMM Location-
Displays information only about the storage shelves with DIMMs that match the specified location.
[-dimm-op-status {unknown|normal|error|not-supported|not-installed}]
- DIMM Operational Status-
Displays information only about the storage shelves with DIMMs that match the specified operational status.
[-boot-device-module-id {A|B}]
- Boot Device Module ID-
Displays information only about the storage shelves with boot devices from the specified module.
[-boot-device-id <integer>,…]
- Boot Device ID-
Displays information only about the storage shelves with boot devices that match the specified ID.
[-boot-device-serial-number <text>,…]
- Boot Device Serial Number-
Displays information only about the storage shelves with boot devices that match the specified serial number.
[-boot-device-part-number <text>,…]
- Boot Device Part Number-
Displays information only about the storage shelves with boot devices that match the specified part number.
[-boot-device-vendor <text>,…]
- Boot Device Vendor-
Displays information only about the storage shelves with boot devices that match the specified vendor.
[-boot-device-type <text>,…]
- Boot Device Type-
Displays information only about the storage shelves with boot devices that match the specified type.
[-boot-device-size <text>,…]
- Boot Device Size-
Displays information only about the storage shelves with boot devices that match the specified size.
[-boot-device-op-status {unknown|normal|error|not-supported|not-installed}]
- Boot Device Operational Status-
Displays information only about the storage shelves with boot devices that match the specified operational status.
[-coin-battery-module-id {A|B}]
- Coin Battery Module ID-
Displays information only about the storage shelves with coin batteries from the specified module.
[-coin-battery-id <integer>,…]
- Coin Battery ID-
Displays information only about the storage shelves with coin batteries that match the specified ID.
[-coin-battery-voltage <integer>,…]
- Coin Battery Voltage (mV)-
Displays information only about the storage shelves with coin batteries that match the specified voltage.
[-coin-battery-op-status {unknown|normal|error|low|high|not-supported|not-installed}]
- Coin Battery Operational Status-
Displays information only about the storage shelves with coin batteries that match the specified operational status.
[-error-type {Unknown|ACPP|Bootdevice|Coinbattery|Configuration|Current|Dimm|Expander|Fan|Module|PCM|Power|Temperature|Voltage}]
- Error Type-
Displays information only about the storage shelves with errors that match the error type you specify.
[-error-severity {unknown|notice|warning|error|critical}]
- Error Severity-
Displays information only about the storage shelves with errors that match the error severity you specify.
Examples
The following example displays information about all storage shelves:
cluster1::> storage shelf show Module Operational Shelf Name Shelf ID Serial Number Model Type Status ----------------- -------- --------------- ----------- ------ ----------- 1.1 1 6000832415 DS2246 IOM6 Critical 1.2 2 6000647652 DS2246 IOM6 Normal 1.3 3 6000003844 DS2246 IOM6 Normal 1.4 4 SHJ000000013A9E DS4246 IOM6 Normal 1.5 5 SHJ000000013A84 DS4246 IOM6 Normal 1.6 6 6000005555 DS2246 IOM6 Normal 6 entries were displayed. cluster1::>
The following example displays expanded information about a storage shelf named 1.2:
cluster1::> storage shelf show -shelf 1.2 -instance Shelf Name: 1.2 Stack ID: 1 Shelf ID: 2 Shelf UID: 50:0a:09:80:01:b9:75:41 Serial Number: 6000647652 Module Type: IOM6 Model: DS2246 Shelf Vendor: FUJITSU Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal Modules: Module is Monitor Is Reporting FW Update Latest Swap Operational Module ID Part No. ES Serial No. is Active Master Element Progress FW Rev. FW Rev. Count Status Location --- ------------ --------------- --------- ------ --------- ------------- ------- ------- ----- ----------- -------------- a 111-00190+A0 8006437891 true false false not-available 0191 - 0 normal rear of the shelf at the top left b 111-00190+A0 8006435180 true true true not-available 0191 - 0 normal rear of the shelf at the top right Paths: Speed Controller Initiator Initiator Side Switch Port Target Side Switch Port Target Port TPGN Gb/s I/O KB/s IOPS ------------------ --------- -------------------------- -------------------------- ------------------ ------ ----- -------- ------- stsw-8020-01 0a - - - - - - - stsw-8020-01 2b - - - - - - - stsw-8020-02 0a - - - - - - - stsw-8020-02 2b - - - - - - - Power Supply Units: Crest Power Reset PSU Operational ID Type Part# Serial# Power Rating Factor Drawn Capable Enabled Firmware Status PSU Location --- ---- ------------ --------------- -------------- ------ ------- ------- ------- -------- ---------------- ------------------------ 1 9C 114-00065+A1 XXT131052637 - - - false true 020F normal rear of the shelf at the bottom left 2 9C 114-00065+A1 XXT131052551 - - - false true 020F normal rear of the shelf at the bottom right Voltage Sensors: Voltage Operational ID (V) Status Sensor Location --- ------- ---------------------- ------------------------ 1 5.70 normal rear of the shelf on the lower left power supply 2 12.300 normal rear of the shelf on the lower left power supply 3 5.70 normal rear of the shelf on the lower right power supply 4 12.180 normal rear of the shelf on the lower right power supply Current Sensors: Current Operational ID (mA) Status Sensor Location --- ------- ---------------------- ------------------------ 1 0 normal rear of the shelf on the lower left power supply 2 0 normal rear of the shelf on the lower left power supply 3 0 normal rear of the shelf on the lower right power supply 4 0 normal rear of the shelf on the lower right power supply Fans: Speed Operational ID (RPM) Status Fan Location --- ------ ----------------------- ---------------------- 1 3000 normal rear of the shelf on the lower left power supply 2 2970 normal rear of the shelf on the lower left power supply 3 3000 normal rear of the shelf on the lower right power supply 4 2970 normal rear of the shelf on the lower right power supply Temperature: -- Thresholds °C -- Temp Is Low Low High High Operational ID °C Ambient Crit Warn Crit Warn Status Sensor Location --- ---- ------- ---- ---- ---- ---- ------------------ -------------------------------- 1 23 true 0 5 42 40 normal front of the shelf on the left, on the OPS panel 2 26 false 5 10 55 50 normal inside of the shelf on the midplane 3 24 false 5 10 55 50 normal rear of the shelf on the lower left power supply 4 39 false 5 10 70 65 normal rear of the shelf on the lower left power supply 5 25 false 5 10 55 50 normal rear of the shelf on the lower right power supply 6 36 false 5 10 70 65 normal rear of the shelf on the lower right power supply 7 25 false 5 10 60 55 normal rear of the shelf at the top left, on shelf module A 8 26 false 5 10 60 55 normal rear of the shelf at the top right, on shelf module B SAS Ports: -- Port Speeds Gb/s -- Power Port Phy # IOM Port Type WWPN Operational Negotiated Status Status ----- --- --------- ----------------- ----------- ---------- ------ ----------- 0 A Square 500a098004b063b0 6.0 - - Enabled 1 A Square 500a098004b063b0 6.0 - - Enabled 2 A Square 500a098004b063b0 6.0 - - Enabled 3 A Square 500a098004b063b0 6.0 - - Enabled 4 A Circle 500a09800569f03f 6.0 - - Enabled 5 A Circle 500a09800569f03f 6.0 - - Enabled 6 A Circle 500a09800569f03f 6.0 - - Enabled 7 A Circle 500a09800569f03f 6.0 - - Enabled 8 A Disk 500605ba00c1cb8d 6.0 6.0 on Enabled 9 A Disk 500605ba00c1ea8d 6.0 6.0 on Enabled 10 A Disk 500605ba00c1d111 6.0 6.0 on Enabled 11 A Disk 500605ba00c1bc49 6.0 6.0 on Enabled 12 A Disk 500605ba00c1cdfd 6.0 6.0 on Enabled 13 A Disk 500605ba00c1c531 6.0 6.0 on Enabled 14 A Disk 500605ba00c1eb05 6.0 6.0 on Enabled 15 A Disk 500605ba00c1ec29 6.0 6.0 on Enabled 16 A Disk 500605ba00c1bc29 6.0 6.0 on Enabled 17 A Disk 500605ba00c1c471 6.0 6.0 on Enabled 18 A Disk 500605ba00c039a9 6.0 6.0 on Enabled 19 A Disk 500605ba00c1c4dd 6.0 6.0 on Enabled 20 A Disk - - - - Empty 21 A Disk - - - - Empty 22 A Disk - - - - Empty 23 A Disk - - - - Empty 24 A Disk - - - - Empty 25 A Disk - - - - Empty 26 A Disk - - - - Empty 27 A Disk - - - - Empty 28 A Disk - - - - Empty 29 A Disk - - - - Empty 30 A Disk - - - - Empty 31 A Disk - - - - Empty 32 A SIL - - - - Disabled 33 A SIL - - - - Disabled 34 A SIL - - - - Disabled 35 A SIL - - - - Disabled 0 B Square 500a098004af9e30 6.0 - - Enabled 1 B Square 500a098004af9e30 6.0 - - Enabled 2 B Square 500a098004af9e30 6.0 - - Enabled 3 B Square 500a098004af9e30 6.0 - - Enabled 4 B Circle 500a098005688dbf 6.0 - - Enabled 5 B Circle 500a098005688dbf 6.0 - - Enabled 6 B Circle 500a098005688dbf 6.0 - - Enabled 7 B Circle 500a098005688dbf 6.0 - - Enabled 8 B Disk 500605ba00c1cb8e 6.0 6.0 on Enabled 9 B Disk 500605ba00c1ea8e 6.0 6.0 on Enabled 10 B Disk 500605ba00c1d112 6.0 6.0 on Enabled 11 B Disk 500605ba00c1bc4a 6.0 6.0 on Enabled 12 B Disk 500605ba00c1cdfe 6.0 6.0 on Enabled 13 B Disk 500605ba00c1c532 6.0 6.0 on Enabled 14 B Disk 500605ba00c1eb06 6.0 6.0 on Enabled 15 B Disk 500605ba00c1ec2a 6.0 6.0 on Enabled 16 B Disk 500605ba00c1bc2a 6.0 6.0 on Enabled 17 B Disk 500605ba00c1c472 6.0 6.0 on Enabled 18 B Disk 500605ba00c039aa 6.0 6.0 on Enabled 19 B Disk 500605ba00c1c4de 6.0 6.0 on Enabled 20 B Disk - - - - Empty 21 B Disk - - - - Empty 22 B Disk - - - - Empty 23 B Disk - - - - Empty 24 B Disk - - - - Empty 25 B Disk - - - - Empty 26 B Disk - - - - Empty 27 B Disk - - - - Empty 28 B Disk - - - - Empty 29 B Disk - - - - Empty 30 B Disk - - - - Empty 31 B Disk - - - - Empty 32 B SIL - - - - Disabled 33 B SIL - - - - Disabled 34 B SIL - - - - Disabled 35 B SIL - - - - Disabled FC Ports: Port ID Port Type Status --- --------- ----------- - - - Bays: Has Operational ID Disk Bay Type Status --- ----- ----------- ----------- 0 true single-disk normal 1 true single-disk normal 2 true single-disk normal 3 true single-disk normal 4 true single-disk normal 5 true single-disk normal 6 true single-disk normal 7 true single-disk normal 8 true single-disk normal 9 true single-disk normal 10 true single-disk normal 11 true single-disk normal 12 false single-disk normal 13 false single-disk normal 14 false single-disk normal 15 false single-disk normal 16 false single-disk normal 17 false single-disk normal 18 false single-disk normal 19 false single-disk normal 20 false single-disk normal 21 false single-disk normal 22 false single-disk normal 23 false single-disk normal cluster1::>
The following example displays information about the power supplies, voltage sensors and current sensors of the storage shelf 1.1:
cluster1::> storage shelf show -shelf 1.1 -power Shelf Name: 1.1 Stack ID: 1 Shelf ID: 1 Shelf UID: 50:0a:09:80:01:cb:d6:84 Serial Number: 6000832415 Module Type: IOM6 Model: DS2246 Shelf Vendor: FUJITSU Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal Power Supply Units: Crest Power Reset PSU Operational ID Type Part# Serial# Power Rating Factor Drawn Capable Enabled Firmware Status --- ---- ------------ --------------- -------------- ------ ------- ------- ------- -------- --------------------- 1 9C 114-00065+A1 XXT132835072 - - - false true 020F normal 2 9C 114-00065+A1 XXT132835073 - - - false true 020F normal Voltage Sensors: Voltage Operational ID (V) Status --- ------- ---------------------- 1 5.70 normal 2 12.180 normal 3 5.70 normal 4 12.300 normal Current Sensors: Current Operational ID (mA) Status --- ------- ---------------------- 1 0 normal 2 0 normal 3 3900 normal 4 0 normal Errors: ------ Critical condition is detected in storage shelf power supply unit "1". The unit might fail. Critical over temperature failure for temperature sensor "1". Current temperature: "75" C ("167" F). cluster1::>
The following example displays information about the cooling elements and temperature sensors inside the storage shelf 1.2:
cluster1::> storage shelf show -shelf 1.2 -cooling Shelf Name: 1.2 Stack ID: 1 Shelf ID: 2 Shelf UID: 50:0a:09:80:01:b9:75:41 Serial Number: 6000647652 Module Type: IOM6 Model: DS2246 Shelf Vendor: FUJITSU Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal Fans: Speed Operational ID (RPM) Status -- ----- ------------- 1 3000 normal 2 3000 normal 3 3000 normal 4 2970 normal Temperature: -- Thresholds °C -- Temp Is Low Low High High Operational ID °C Ambient Crit Warn Crit Warn Status --- ---- ------- ---- ---- ---- ---- ------------------ 1 23 true 0 5 42 40 normal 2 26 false 5 10 55 50 normal 3 24 false 5 10 55 50 normal 4 39 false 5 10 70 65 normal 5 25 false 5 10 55 50 normal 6 36 false 5 10 70 65 normal 7 25 false 5 10 60 55 normal 8 27 false 5 10 60 55 normal Errors: ------ - cluster1::>
The following example displays information about the connectivity from the node to the storage shelf 1.2:
cluster1::> storage shelf show -shelf 1.2 -connectivity Shelf Name: 1.2 Stack ID: 1 Shelf ID: 2 Shelf UID: 50:0a:09:80:01:b9:75:41 Serial Number: 6000647652 Module Type: IOM6 Model: DS2246 Shelf Vendor: FUJITSU Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal Paths: Controller Initiator Initiator Side Switch Port Target Side Switch Port Target Port TPGN ------------------ --------- -------------------------- -------------------------- ------------------ ------ stsw-8020-01 0a - - - - stsw-8020-01 2b - - - - stsw-8020-02 0a - - - - stsw-8020-02 2b - - - - Errors: ------ - cluster1::>
The following example displays information about the disk bays of the storage shelf 1.2:
cluster1::> storage shelf show -shelf 1.2 -bay Shelf Name: 1.2 Stack ID: 1 Shelf ID: 2 Shelf UID: 50:0a:09:80:01:b9:75:41 Serial Number: 6000647652 Module Type: IOM6 Model: DS2246 Shelf Vendor: FUJITSU Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal Bays: Has Operational ID Disk Bay Type Status --- ----- ----------- ----------- 0 true single-disk normal 1 true single-disk normal 2 true single-disk normal 3 true single-disk normal 4 true single-disk normal 5 true single-disk normal 6 true single-disk normal 7 true single-disk normal 8 true single-disk normal 9 true single-disk normal 10 true single-disk normal 11 true single-disk normal 12 false single-disk normal 13 false single-disk normal 14 false single-disk normal 15 false single-disk normal 16 false single-disk normal 17 false single-disk normal 18 false single-disk normal 19 false single-disk normal 20 false single-disk normal 21 false single-disk normal 22 false single-disk normal 23 false single-disk normal Errors: ------ - cluster1::>
The following example displays information about the ports of the storage shelf 1.2:
cluster1::> storage shelf show -shelf 1.2 -port Shelf Name: 1.2 Stack ID: 1 Shelf ID: 2 Shelf UID: 50:0a:09:80:01:b9:75:41 Serial Number: 6000647652 Module Type: IOM6 Model: DS2246 Shelf Vendor: FUJITSU Disk Count: 12 Connection Type: SAS Shelf State: Online Status: Normal SAS Ports: -- Port Speeds Gb/s -- Power Port Phy # IOM Port Type WWPN Operational Negotiated Status Status ----- --- --------- ----------------- ----------- ---------- ------ ----------- 0 A Square 500a098004b063b0 6.0 - - Enabled 1 A Square 500a098004b063b0 6.0 - - Enabled 2 A Square 500a098004b063b0 6.0 - - Enabled 3 A Square 500a098004b063b0 6.0 - - Enabled 4 A Circle 500a09800569f03f 6.0 - - Enabled 5 A Circle 500a09800569f03f 6.0 - - Enabled 6 A Circle 500a09800569f03f 6.0 - - Enabled 7 A Circle 500a09800569f03f 6.0 - - Enabled 8 A Disk 500605ba00c1cb8d 6.0 6.0 on Enabled 9 A Disk 500605ba00c1ea8d 6.0 6.0 on Enabled 10 A Disk 500605ba00c1d111 6.0 6.0 on Enabled 11 A Disk 500605ba00c1bc49 6.0 6.0 on Enabled 12 A Disk 500605ba00c1cdfd 6.0 6.0 on Enabled 13 A Disk 500605ba00c1c531 6.0 6.0 on Enabled 14 A Disk 500605ba00c1eb05 6.0 6.0 on Enabled 15 A Disk 500605ba00c1ec29 6.0 6.0 on Enabled 16 A Disk 500605ba00c1bc29 6.0 6.0 on Enabled 17 A Disk 500605ba00c1c471 6.0 6.0 on Enabled 18 A Disk 500605ba00c039a9 6.0 6.0 on Enabled 19 A Disk 500605ba00c1c4dd 6.0 6.0 on Enabled 20 A Disk - - - - Empty 21 A Disk - - - - Empty 22 A Disk - - - - Empty 23 A Disk - - - - Empty 24 A Disk - - - - Empty 25 A Disk - - - - Empty 26 A Disk - - - - Empty 27 A Disk - - - - Empty 28 A Disk - - - - Empty 29 A Disk - - - - Empty 30 A Disk - - - - Empty 31 A Disk - - - - Empty 32 A SIL - - - - Disabled 33 A SIL - - - - Disabled 34 A SIL - - - - Disabled 35 A SIL - - - - Disabled 0 B Square 500a098004af9e30 6.0 - - Enabled 1 B Square 500a098004af9e30 6.0 - - Enabled 2 B Square 500a098004af9e30 6.0 - - Enabled 3 B Square 500a098004af9e30 6.0 - - Enabled 4 B Circle 500a098005688dbf 6.0 - - Enabled 5 B Circle 500a098005688dbf 6.0 - - Enabled 6 B Circle 500a098005688dbf 6.0 - - Enabled 7 B Circle 500a098005688dbf 6.0 - - Enabled 8 B Disk 500605ba00c1cb8e 6.0 6.0 on Enabled 9 B Disk 500605ba00c1ea8e 6.0 6.0 on Enabled 10 B Disk 500605ba00c1d112 6.0 6.0 on Enabled 11 B Disk 500605ba00c1bc4a 6.0 6.0 on Enabled 12 B Disk 500605ba00c1cdfe 6.0 6.0 on Enabled 13 B Disk 500605ba00c1c532 6.0 6.0 on Enabled 14 B Disk 500605ba00c1eb06 6.0 6.0 on Enabled 15 B Disk 500605ba00c1ec2a 6.0 6.0 on Enabled 16 B Disk 500605ba00c1bc2a 6.0 6.0 on Enabled 17 B Disk 500605ba00c1c472 6.0 6.0 on Enabled 18 B Disk 500605ba00c039aa 6.0 6.0 on Enabled 19 B Disk 500605ba00c1c4de 6.0 6.0 on Enabled 20 B Disk - - - - Empty 21 B Disk - - - - Empty 22 B Disk - - - - Empty 23 B Disk - - - - Empty 24 B Disk - - - - Empty 25 B Disk - - - - Empty 26 B Disk - - - - Empty 27 B Disk - - - - Empty 28 B Disk - - - - Empty 29 B Disk - - - - Empty 30 B Disk - - - - Empty 31 B Disk - - - - Empty 32 B SIL - - - - Disabled 33 B SIL - - - - Disabled 34 B SIL - - - - Disabled 35 B SIL - - - - Disabled FC Ports: Port ID Port Type Status --- --------- ----------- - - - Errors: ------ - cluster1::>
The following example displays error information about the storage shelves that have errors:
cluster1::> storage shelf show -errors Shelf Name: 1.1 Shelf UID: 50:0a:09:80:01:cb:d6:84 Serial Number: 6000832415 Error Type Description ------------------ --------------------------- Power Critical condition is detected in storage shelf power supply unit "1". The unit might fail. Temperature Critical over temperature failure for temperature sensor "1". Current temperature: "75" C ("167" F).