ONTAP 9.14.1 commands

system switch ethernet power show

Display power information for Ethernet switches (cluster, management and storage).

Availability: This command is available to cluster administrators at the admin privilege level.

Description

The system switch ethernet power show command displays the power supply status of the monitored Ethernet switches.

Parameters

{ [-fields <fieldname>,…​]

Selects the fields with the names that you specify.

| [-instance ] }

Displays detailed power supply information for all the switches.

[-device <text>] - Switch Name

Selects the PSUs that belong to the specified switch.

[-psu-name <text>] - Power Supply Name

Selects the PSUs that match the specified power supply name.

[-oper-status {operational|failed|not-operational|not-present|unknown}] - Operational Status

Selects the PSUs that match the specified operational status.

[-error-description <text>] - Error Description

Selects the PSUs that match the specified error description.

[-display-name <text>] - Power Supply Display Name

Selects the PSUs that match the specified display name.

[-unique-name <text>] - Power Supply Unique Name

Selects the PSU that matches the specified unique name.

[-status {ok|ok-with-suppressed|degraded|unreachable|unknown}] - Power Supply Resource Health

Selects the PSUs that match the specified status.

[-monitor {node-connect|system-connect|system|controller|chassis|cluster-switch|example|ethernet-switch}] - Health Monitor

Selects the PSUs that match the specified monitor type.

[-admin-status {on|off|not-defined|unknown}] - Adminstrative Status

Selects the PSUs that match the specified administrative status for the power supply.

Examples

cluster1::> system switch ethernet power show
                                     Admin      Operational
Switch             Power Supply      Status     Status       Error
------------------ ----------------- ---------- -----------  ---------------
SwitchA            PowerSupply-1     on         operational
SwitchA            PowerSupply-2     on         operational

The example above displays the power-supply status for all Ethernet switches (cluster, management and storage).

Top of Page