MetroCluster Manuals ( CA08871-401 )

to Japanese version

Requirements and limitations when using MetroCluster-compliant switches

Beginning with ONTAP 9.7, MetroCluster IP configurations can use MetroCluster-compliant switches. These are switches that are not our validated but are compliant with our specifications. However, We do not provide troubleshooting or configuration support services for any non-validated switch. You should be aware of the general requirements and limitations when using MetroCluster-compliant switches.

General requirements for MetroCluster-compliant switches

The switch connecting the MetroCluster IP interfaces must meet the following general requirements:

  • The switches must support quality of service (QoS) and traffic classification.

  • The switches must support explicit congestion notification (ECN).

  • The switches must support a load-balancing policy to preserve order along the path.

  • The switch port must provide a dedicated rate and must not be overallocated.

  • The cables and transceivers connecting the nodes to the switches must be provided by us. These cables must be supported by the switch vendor. If you are using optical cabling, the transceiver in the switch might not be provided by us. You must verify that it is compatible with the transceiver in the controller.

  • The switches connecting the MetroCluster nodes can carry non-MetroCluster traffic.

  • Only platforms that provide dedicated ports for switchless cluster interconnects can be used with a MetroCluster-compliant switch. Platforms such as the ETERNUS HX2200 and ETERNUS AX2100 cannot be used because MetroCluster traffic and MetroCluster interconnect traffic share the same network ports.

  • The MetroCluster-compliant switch must not be used for local cluster connections.

  • The MetroCluster IP interface can be connected to any switch port that can be configured to meet the requirements.

  • Four IP switches are required, two for each switch fabric. If you use directors, then you can use a single director at each side, but the MetroCluster IP interfaces must connect to two different blades in two different failure domains on that director.

  • The MetroCluster interfaces from one node must connect to two network switches or blades. The MetroCluster interfaces from one node cannot be connected to the same network or switch or blade.

  • The network must meet the requirements outlined in the following sections:

  • The maximum transmission unit (MTU) of 9216 must be configured on all switches that carry MetroCluster IP traffic.

Any intermediate switches that you use between the switches connecting the MetroCluster IP interfaces at both sites must meet the requirements and must be configured as outlined in Considerations when deploying MetroCluster in shared layer 2 or layer 3 networks.

Limitations when using MetroCluster-compliant switches

You cannot use any configuration or feature that requires that local cluster connections are connected to a switch. For example, you cannot use the following configurations and procedures with a MetroCluster-compliant switch:

Top of Page