ONTAP 9.12.1 commands

50←PDF
  • ONTAP 9.12.1 commands(CA08871-263en.pdf)
  • storage failover hwassist test

    Test the hwassist functionality

    Availability: This command is available to cluster administrators at the admin privilege level.

    Description

    The ` storage failover hwassist test` command tests the Hardware Assist h/w connectivity between the two nodes in a HA pair. The test result can be one of the following.

    • Hardware Assist is not initialized.

    • HW assist is not supported.

    • Partner is throttling alerts.

    • Resource is busy.

    • Hardware Assist h/w returned an error.

    • No response from partner.Timed out.

    • Unexpected abort.

    • Partner has taken over.

    • Interconnect is down between nodes.

    • Partner is not booted up yet.

    Parameters

    -node {<nodename>|local} - Node

    This specifies the node from which a test alert is initiated.

    Examples

    The following command issues a test alert from the node cluster1-01:

    cluster1::> storage failover hwassist test -node cluster1-01
    Info: Operation successful.
    Top of Page