ONTAP 9.12.1 commands

50←PDF
  • ONTAP 9.12.1 commands(CA08871-263en.pdf)
  • storage shelf acp show

    Show connectivity information

    Availability: This command is available to cluster administrators at the admin privilege level.

    Description

    Displays information about the ACP connectivity on each node

    Parameters

    { [-fields <fieldname>,…​]

    If you specify the -fields <field-name>", …​ parameter, the command output also includes the specified field or fields. You can use '-fields ?' to display the fields to specify.

    | [-errors ]

    If you specify the -errors parameter, the command displays detailed information about all modules with errors.

    | [-instance ] }

    If you specify the -instance parameter, the command displays detailed information about all fields.

    [-node {<nodename>|local}] - Node

    Selects the nodes that match this parameter value.

    [-is-enabled {true|false}] - Is Enabled?

    Selects the nodes that are enabled or disabled.

    [-port <text>] - Port

    Selects the nodes that match the specified port on which ACP is configured.

    [-address <IP Address>] - IP Address

    Selects the nodes with the specified IP address.

    [-subnet <IP Address>] - Subnet

    Selects the nodes with the specified subnet.

    [-netmask <IP Address>] - Netmask

    Selects the nodes with the specifed netmask.

    [-connection-status {no-connectivity|partial-connectivity|full-connectivity|additional-connectivity|unknown-connectivity|not-available|connection-disabled}] - Connection Status

    Selects the nodes with the specified connection status.

    [-error-id <integer>] - Error ID

    Selects the node with the specified error ID.

    [-error-type {No-Error|Connection-Issue|Connection-Activity|Module-Error|Shelf-Error}] - Error Type

    The error type, in case of a connection error.

    [-error-severity {unknown|notice|warning|error|critical}] - Error Severity

    The error severity, in case of a connection error.

    [-error-text <text>] - Error Text

    Selects the node with the specified error text.

    [-corrective-action <text>] - Corrective Action

    Selects the node with the specified corrective action.

    [-channel {unknown|out-of-band|in-band}] - Channel

    Selects the nodes that has channel configured out-of-band or in-band.

    Examples

    The following example displays ACP connectivity on each node (in-band):

    fas2750-2n-rtp-1::> storage shelf acp show
      Node                Channel                Connectivity
            ------------------  --------------------   ----------------------
      fas2750-rtp-1a      in-band                active
      fas2750-rtp-1b      in-band                active
      2 entries were displayed.

    The following example displays ACP connectivity on each node (out of band):

    fas2750-2n-rtp-1::> storage shelf acp show
            Node                Channel                Connectivity
      ------------------  --------------------   ----------------------
      fas2750-rtp-1a      out-of-band            full-connectivity
      fas2750-rtp-1b      out-of-band            full-connectivity
      2 entries were displayed.

    The following example displays the -instance output of the storage acp show (in-band) command. Use this command to display details on connectivity and configuration.

    fas2750-2n-rtp-1::> storage shelf acp show -instance
                     Node: fas2750-rtp-1a
            Channel: in-band
            Enable Status: true
        Connection Status: active
    Node: fas2750-rtp-1b
            Channel: in-band
            Enable Status: true
        Connection Status: active
        2 entries were displayed.

    The following example displays the -instance output of the storage acp show (out-of-band) command. Use this command to display details on connectivity and configuration.

    fas2750-2n-rtp-1::> storage shelf acp show -instance
         Node: fas2750-rtp-1a
            Channel: out-of-band
      Enable Status: true
         Port: e0P
         IP Address: 192.168.1.74
             Subnet: 192.168.0.1
            Netmask: 255.255.252.0
        Connection Status: full-connectivity
    Node: fas2750-rtp-1b
            Channel: out-of-band
      Enable Status: true
         Port: e0P
         IP Address: 192.168.1.75
             Subnet: 192.168.0.1
            Netmask: 255.255.252.0
        Connection Status: full-connectivity
        2 entries were displayed.
    Top of Page