ONTAP 9.12.1 commands
system switch fibre-channel show
Display back-end fibre-channel switch information
Availability: This command is available to cluster administrators at the admin privilege level.
Description
The system switch fibre-channel show
command displays information about all the back-end fibre-channel (FC) switches in the MetroCluster configuration. The back-end switches must have been previously added for monitoring using the system switch fibre-channel add command. If no parameters are specified, the default command displays the following information about the back-end FC switches:
-
Switch
-
Symbolic Name
-
Vendor
-
Model
-
Switch WWN
-
Is Monitored
-
Monitor Status
To display detailed profile information about a single back-end FC switch, use the -switch-name
parameter.
Parameters
- {
[-fields <fieldname>,…]
-
Displays the specified fields for all the back-end FC switches, in column-style output.
- |
[-connectivity ]
-
Displays the following details about the connectivity from the back-end FC switch to connected entities:
-
Port name
-
Port operating mode
-
Port world wide name
-
Peer port world wide name
-
Peer type
-
Additional information about peer
Displays the following details about the connectivity from the node to the back-end FC switch:
-
Node name
-
Adapter name
-
Switch port name
-
Switch port speed
-
Adapter type
-
- |
[-cooling ]
-
Displays the following details about the fans and temperature sensors on the back-end FC switch:
-
Fan name
-
Fan speed in rotations per minute (RPM)
-
Fan operational status
-
Temperature sensor name
-
Temperature sensor reading in Celsius ©
-
Temperature sensor status
-
- |
[-error ]
-
Displays the errors related to the back-end FC switch.
- |
[-port ]
-
Displays the following details about the back-end FC switch ports:
-
Port name
-
Port world wide name
-
Port administrative status
-
Port operational status
-
Port operating mode
-
Whether SFP is present in the port
-
Port speed in gigabits per second (Gbps)
-
Port BB credit
-
Peer port world wide name
-
- |
[-power ]
-
Displays the following details about the back-end FC switch power supplies:
-
Power supply name
-
Power supply serial number
-
Power supply operational status
-
- |
[-san-config ]
-
Displays the following details about the Virtual Storage Area Networks (VSAN) and Zones of the back-end FC switch:
-
VSAN identifier
-
VSAN name
-
VSAN operational status
-
Type of load balancing configured for the VSAN
-
Where in-order-delivery set for the VSAN
-
Whether the auto power reset of the PSU is enabled
-
VAN member switch name and port
-
Zone name
-
VSAN ID of the zone
-
Zone member switch name and port
-
Zone member port id
-
Zone member port world wide name
-
- |
[-sfp ]
-
Displays the following details about the back-end FC switch ports small form-factor pluggable (SFP):
-
Port name
-
Type of SFP
-
SFP transmitter type
-
SFP vendor
-
SFP part number
-
SFP serial number
-
- |
[-stats ]
-
Displays the following details about the back-end FC switch ports:
-
Port name
-
Frames received through the port (Rx Frames)
-
Frames transmitted through the port (Tx Frames)
-
Octets received through the port (Rx Octets)
-
Octets transmitted through the port (Tx Octets)
-
Port error frames
-
- |
[-instance ]
} -
Displays expanded information about all the back-end FC switches in the system. If a back-end FC switch is specified, then this parameter displays the same detailed information for the back-end FC switch you specify as does the -switch-name parameter.
[-switch-name <text>]
- FC Switch Name-
Displays information only about the back-end FC switches that match the name you specify.
[-switch-wwn <text>]
- Switch World Wide Name-
Displays information only about the back-end FC switches that match the switch wwn you specify.
[-switch-symbolic-name <text>]
- Switch Symbolic Name-
Displays information only about the back-end FC switches that match the switch symbolic name you specify.
[-switch-fabric-name <text>]
- Fabric Name-
Displays information only about the back-end FC switches that match the switch fabric you specify.
[-domain-id <integer>]
- Switch Domain ID-
Displays information only about the back-end FC switches that match the switch domain id you specify.
[-switch-role {unknown|primary|subordinate}]
- Switch Role in Fabric-
Displays information only about the back-end FC switches that match the switch role you specify.
[-snmp-version {SNMPv1|SNMPv2c|SNMPv3}]
- SNMP Version-
Displays information only about the back-end FC switches that match the switch SNMP version you specify.
[-switch-model <text>]
- Switch Model-
Displays information only about the back-end FC switches that match the switch model you specify.
[-switch-vendor {unknown|Brocade|Cisco}]
- Switch Vendor-
Displays information only about the back-end FC switches that match the switch vendor you specify.
[-fw-version <text>]
- Switch Firmware Version-
Displays information only about the back-end FC switches that match the switch firmware version you specify.
[-serial-number <text>]
- Switch Serial Number-
Displays information only about the back-end FC switches that match the switch serial number you specify.
[-switch-ipaddress <IP Address>]
- Switch IP Address-
Displays information only about the back-end FC switches that match the switch IP address you specify.
[-switch-status {unknown|ok|error}]
- Switch Status-
Displays information only about the back-end FC switches that match the switch status you specify.
[-snmp-community-or-username <text>]
- SNMPv2c Community or SNMPv3 Username-
Displays information only about the back-end FC switches that match the switch SNMPv2c community or SNMPv3 username you specify.
[-profile-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Profile Data Last Successful Refresh Timestamp-
Displays information only about the back-end FC switches that match the profile data last successful refresh timestamp you specify.
[-is-monitoring-enabled {true|false}]
- Is Monitoring Enabled for Switch-
Displays information only about the back-end FC switches that match the switch monitoring value you specify.
[-blades <integer>,…]
- Director-Class Switch Blades to Monitor-
Displays information only about the back-end FC switches that match the blade value you specify.
[-engine-id <Hex String>]
- Engine ID of SNMPv3 Capable Switch-
Displays information only about the back-end FC switches that match the SNMPv3 engine-id you specify.
[-psu-name-list <text>,…]
- Switch Power Supply Name List-
Displays information only about the back-end FC switches that have the power supply units with the names you specify.
[-psu-serial-number-list <text>,…]
- Switch Power Supply Serial Number List-
Displays information only about the back-end FC switches that have the power supply units with the serial numbers you specify.
[-psu-status-list {unknown|normal|warning|faulty|not-present}]
- Switch Power Supply Status List-
Displays information only about the back-end FC switches that have the power supply units with the statuses you specify.
[-psu-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Power Supply Data Last Successful Refresh Timestamp-
Displays information only about the back-end FC switches that match the power supply unit data last successful refresh timestamp you specify.
[-temp-sensor-name-list <text>,…]
- Switch Temperature Sensor Name List-
Displays information only about the back-end FC switches that have the temperature sensors with the names you specify.
[-temp-sensor-reading-list <integer>,…]
- Switch Temperature Sensor Reading © List-
Displays information only about the back-end FC switches that have the temperature sensors with the readings you specify.
[-temp-sensor-status-list {unknown|normal|warning|critical}]
- Switch Temperature Sensor Status List-
Displays information only about the back-end FC switches that have the temperature sensors with the statuses you specify.
[-temp-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Temperature Sensor Data Last Successful Refresh Timestamp-
Displays information only about the back-end FC switches that match the temperature sensor data last successful refresh timestamp you specify.
[-fan-name-list <text>,…]
- Switch Fan Name List-
Displays information only about the back-end FC switches that match the fans with the names you specify.
[-fan-rpm-list <integer>,…]
- Switch Fan Speed (RPM) List-
Displays information only about the back-end FC switches that match the fans with the RPM speeds you specify.
[-fan-status-list {unknown|operational|failed|not-operational|not-present}]
- Switch Fan Operational Status List-
Displays information only about the back-end FC switches that match the fans with the statuses you specify.
[-fan-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Fan Data Last Successful Refresh Timestamp-
Displays information only about the back-end FC switches that match the fan data last successful refresh timestamp you specify.
[-vsan-index-list <integer>,…]
- Switch VSAN Index List-
Displays information only about the back-end FC switches that have the VSANs with the indexes you specify.
[-vsan-name-list <text>,…]
- Switch VSAN Name List-
Displays information only about the back-end FC switches that have the VSANs with the names you specify.
[-vsan-oper-status-list {up|down}]
- Switch VSAN Operational Status List-
Displays information only about the back-end FC switches that have the VSANs with the operational statuses you specify.
[-vsan-load-balancing-type-list {src-id-dest-id|src-id-dest-id-ox-id}]
- Switch VSAN Load balancing Type List-
Displays information only about the back-end FC switches that have the VSANs with the load balancing types you specify.
[-is-vsan-iod-list {true|false}]
- Is In-order Delivery Set for VSAN List-
Displays information only about the back-end FC switches that have the VSANs with the IOD setting you specify.
[-vsan-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch VSAN Data Last Successful Refresh Timestamp-
Displays information only about the back-end FC switches that match the VSAN data last successful refresh timestamp you specify.
[-member-switch-name-list <text>,…]
- Member Switch List-
Displays information only about the back-end FC switches that have the VSANs with the member switch names you specify.
[-member-switch-port-name-list <text>,…]
- Member Switch Port Name List-
Displays information only about the back-end FC switches that have the VSANs with the memeber switch port names you specify.
[-vsan-id-list <integer>,…]
- Zone VSAN ID List-
Displays information only about the back-end FC switches that have the VSANs with the IDs you specify.
[-zone-name-list <text>,…]
- Switch Zone Name List-
Displays information only about the back-end FC switches that have the zones with the names you specify.
[-zone-member-sw-domain-id-list <integer>,…]
- Zone Member Switch Port Domain ID List-
Displays information only about the back-end FC switches that have the zones with the member switch domain ids you specify.
[-zone-member-port-name-list <text>,…]
- Zone Member Port List-
Displays information only about the back-end FC switches that have the zones with the port names you specify.
[-zone-member-port-wwn-list <text>,…]
- Zone Member WWPN List-
Displays information only about the back-end FC switches that have the zones with the port WWNs you specify.
[-zone-member-port-switch-name-list <text>,…]
- Zone Member Switch WWN List-
Displays information only about the back-end FC switches that have the zones with the member port hosting switch names you specify.
[-zone-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Zone Data Last Successful Refresh Timestamp-
Displays information only about the back-end FC switches that match the zone data last successful refresh timestamp you specify.
[-zone-member-wwn-list <text>,…]
- Zone Member WWN List-
Displays information only about the back-end FC switches that have the zones with the member WWNs you specify.
[-zone-member-port-id-list <text>,…]
- Zone Member Port ID List-
Displays information only about the back-end FC switches that have the zones with the member port ids you specify.
[-port-wwn-list <text>,…]
- Switch Port World Wide Name (WWPN) List-
Displays information only about the back-end FC switches that have the ports with the WWNs you specify.
[-port-name-list <text>,…]
- Switch Port Name List-
Displays information only about the back-end FC switches that have the ports with the names you specify.
[-port-admin-status-list {unknown|enabled|disabled}]
- Switch Port Admin Status List-
Displays information only about the back-end FC switches that have the ports with administrative statuses you specify.
[-port-oper-status-list {unknown|online|offline}]
- Switch Port Operational Status List-
Displays information only about the back-end FC switches that have the ports with operational statuses you specify.
[-port-mode-list {unknown|auto|F-port|FL-port|E-port|TE-port|U-port|G-port|other|EX-port|D-port|SIM-port|VE-port|AE-port|AF-port}]
- Switch Port Mode List-
Displays information only about the back-end FC switches that have the ports with the operating modes you specify.
[-port-oper-speed-list <integer>,…]
- Switch Port Current Speed (in Gbits/sec) List-
Displays information only about the back-end FC switches that have the ports with the operational speeds you specify.
[-port-bb-credit-list <integer>,…]
- Switch Port BB Credit List-
Displays information only about the back-end FC switches that have the ports with the BB credits you specify.
[-port-sfp-present-list {true|false}]
- Switch Port Is SFP Present List-
Displays information only about the back-end FC switches that have the ports with the SFP present values you specify.
[-port-peer-wwpn-list <text>,…]
- Switch Port Peer WWPN List-
Displays information only about the back-end FC switches that have the ports with the peer port WWPNs you specify.
[-port-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Port Data Last Successful Refresh Timestamp-
Displays information only about the back-end FC switches that match the port data last successful refresh timestamp you specify.
[-port-stat-name-list <text>,…]
- Switch Port Name List-
Displays information only about the back-end FC switches that have the ports with the names you specify.
[-port-tx-frames-list <integer>,…]
- Switch Port Transmitted Frame Count List-
Displays information only about the back-end FC switches that have the ports with the transmitted frames values you specify.
[-port-rx-frames-list <integer>,…]
- Switch Port Received Frame Count List-
Displays information only about the back-end FC switches that have the ports with the received frames values you specify.
[-port-tx-octets-list <integer>,…]
- Switch Port Total Transmitted Octets List-
Displays information only about the back-end FC switches that have the ports with the transmitted octets values you specify.
[-port-rx-octets-list <integer>,…]
- Switch Port Total Received Octets List-
Displays information only about the back-end FC switches that have the ports with the received octets values you specify.
[-port-frame-error-list <integer>,…]
- Switch Port Frame Error Count List-
Displays information only about the back-end FC switches that have the ports with the error frame values you specify.
[-port-stat-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Port Stat Data Last Update Timestamp-
Displays information only about the back-end FC switches that match the port statistics data last successful refresh timestamp you specify.
[-sfp-port-name-list <text>,…]
- Switch Port Name List-
Displays information only about the back-end FC switches that have the ports with the names you specify.
[-sfp-type-list {unknown|other|gbic|embedded|glm|gbic-with-serial-id|gbic-without-serial-id|sfp-with-serial-id|sfp-without-serial-id|xfp|x2-short|x2-medium|x2-tall|xpak-short|xpak-medium|xpak-tall|xenpak|sfp-dw-dm|qsfp|x2-dw-dm|gbic-not-installed|small-form-factor}]
- Switch Port SFP Type List-
Displays information only about the back-end FC switches that have the ports with the SFP types you specify.
[-sfp-tx-type-list {unknown|long-wave-laser|short-wave-laser|long-wave-laser-cost-reduced|electrical|ten-gig-base-sr|ten-gig-base-lr|ten-gig-base-er|ten-gig-base-lx4|ten-gig-base-sw|ten-gig-base-lw|ten-gig-base-ew}]
- Switch Port SFP Transmitter Type List-
Displays information only about the back-end FC switches that have the ports with the SFP transmitter types you specify.
[-sfp-vendor-list <text>,…]
- Switch Port SFP Vendor List-
Displays information only about the back-end FC switches that have the ports with the SFP vendors you specify.
[-sfp-part-number-list <text>,…]
- Switch Port SFP Part Number List-
Displays information only about the back-end FC switches that have the ports with the SFP part numbers you specify.
[-sfp-serial-number-list <text>,…]
- Switch Port SFP Serial Number List-
Displays information only about the back-end FC switches that have the ports with the SFP serial numbers you specify.
[-sfp-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Port SFP Data Last Successful Refresh Timestamp-
Displays information only about the back-end FC switches that match the port SFP data last successful refresh timestamp you specify.
[-switch-error-text-list <text>,…]
- Switch Error Text List-
Displays information only about the back-end FC switches that have the errors you specify.
[-conn-switch-port-name-list <text>,…]
- Switch Port Name List-
Displays information only about the back-end FC switches that have the ports with the names you specify.
[-conn-switch-port-mode-list {unknown|auto|F-port|FL-port|E-port|TE-port|U-port|G-port|other|EX-port|D-port|SIM-port|VE-port|AE-port|AF-port}]
- Switch Port Operating Mode List-
Displays information only about the back-end FC switches that have the ports with the operating modes you specify.
[-conn-switch-port-wwn-list <text>,…]
- Switch Port WWN List-
Displays information only about the back-end FC switches that have the ports with the WWNs you specify.
[-conn-switch-port-peer-port-wwn-list <text>,…]
- Switch Port Peer Port WWN List-
Displays information only about the back-end FC switches that have the ports with the peer port WWNs you specify.
[-conn-switch-port-peer-info-list <text>,…]
- Switch Port Peer Host & Port Name List-
Displays information only about the back-end FC switches that have the ports with the peer information values you specify.
[-conn-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Connectivity Data Last Successful Refresh Timestamp-
Displays information only about the back-end FC switches that match the switch connectivity data last successful refresh timestamp you specify.
[-conn-switch-port-peer-type-list {unknown|bridge|switch|fcp-adapter|fcvi-adapter}]
- Switch Port Peer Type List-
Displays information only about the back-end FC switches that have the ports connected to the peer types you specify.
[-switch-port-name-list <text>,…]
- Switch Port Name List-
Displays information only about the back-end FC switches that have the ports with the names you specify.
[-switch-port-speed-list <integer>,…]
- Switch Port Speed (in Gbps) List-
Displays information only about the back-end FC switches that have the ports with the speeds you specify.
[-node-name-list <nodename>,…]
- Node Name List-
Displays information only about the back-end FC switches that are connected to the nodes you specify.
[-adapter-name-list <text>,…]
- Node Adapter Name List-
Displays information only about the back-end FC switches that are connected to the adapters you specify.
[-adapter-port-name-list <text>,…]
- Node Adapter Port Name List-
Displays information only about the back-end FC switches that are connected to the adapter ports you specify.
[-adapter-type-list {unknown|FCP-Initiator|FC-VI|FCP-Target}]
- Node Adapter Type List-
Displays information only about the back-end FC switches that are connected to the types of adapters you specify.
[-path-data-last-successful-refresh-timestamp {MM/DD/YYYY HH:MM:SS [{+|-}hh:mm]}]
- Switch Path Data Last Successful Refresh Timestamp-
Displays information only about the back-end FC switches that match the node to switch path data last successful refresh timestamp you specify.
[-name-list <text>,…]
- Switch Name List-
Displays information only about the back-end FC switches that match the names you specify.
[-domain-id-list <integer>,…]
- Switch Domain ID List-
Displays information only about the back-end FC switches that match the domain ids you specify.
[-wwn-list <text>,…]
- Switch WWN List-
Displays information only about the back-end FC switches that match the switch WWNs you specify.
[-role-list {unknown|primary|subordinate}]
- Switch Role in Fabric List-
Displays information only about the back-end FC switches that match the switch roles you specify.
[-address-list <IP Address>,…]
- Switch IP Address List-
Displays information only about the back-end FC switches that match the switch IP addresses you specify.
Examples
The following example displays information about all back-end FC switches:
cluster::> system switch fibre-channel show Symbolic Is Monitor Switch Name Vendor Model Switch WWN Monitored Status ----------- -------- ------- ---------- ---------------- --------- ------- Cisco_10.226.197.34 mcc-cisco-8Gb-fab-4 Cisco DS-C9148-16P-K9 2000547fee78f088 true ok Cisco_10.226.197.35 mcc-cisco-8Gb-fab-3 Cisco DS-C9148-16P-K9 2000547fee78f0f0 true ok Cisco_10.226.197.36 mcc-cisco-8Gb-fab-2 Cisco DS-C9148-16P-K9 2000547fee78efb0 true ok Cisco_10.226.197.37 mcc-cisco-8Gb-fab-1 Cisco DS-C9148-16P-K9 2000547fee78f0d8 true ok 4 entries were displayed. cluster::>
The following example displays connectivity (switch to peer and node to switch) information about all back-end FC switches:
cluster::> system switch fibre-channel show -connectivity Switch Name: Cisco_10.226.197.36 Switch WWN: 2000547fee78efb0 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:16:42 -04:00 Connectivity: Port Name Port Mode Port WWN Peer Port WWN Peer Type Peer Info --------- --------- ---------------- ---------------- ------------ --------- fc1/1 F-port 2001547fee78efb0 2100001086607d34 unknown unknown fc1/3 F-port 2003547fee78efb0 21000024ff3dd9cb unknown unknown fc1/4 F-port 2004547fee78efb0 21000024ff3dda8d unknown unknown fc1/5 F-port 2005547fee78efb0 500a0980009af880 unknown unknown fc1/6 F-port 2006547fee78efb0 500a0981009af370 unknown unknown fc1/11 TE-port 200b547fee78efb0 200b547fee78f088 switch Cisco_10.226.197.34:fc1/11 fc1/12 TE-port 200c547fee78efb0 200c547fee78f088 switch Cisco_10.226.197.34:fc1/12 fc1/13 F-port 200d547fee78efb0 2100001086609e22 unknown unknown fc1/15 F-port 200f547fee78efb0 21000024ff3dd91b unknown unknown fc1/16 F-port 2010547fee78efb0 21000024ff3dbef5 unknown unknown fc1/17 F-port 2011547fee78efb0 500a0981009afda0 unknown unknown fc1/18 F-port 2012547fee78efb0 500a0981009a9160 unknown unknown fc1/25 F-port 2019547fee78efb0 21000010866037e8 bridge ATTO_10.226.197.17:1 fc1/27 F-port 201b547fee78efb0 21000024ff3dd9d3 fcvi-adapter dpg-mcc-3240-15-a1:fcvi_device_1 fc1/28 F-port 201c547fee78efb0 21000024ff3dbe3d fcvi-adapter dpg-mcc-3240-15-a2:fcvi_device_1 fc1/29 F-port 201d547fee78efb0 500a0980009ae0a0 fcp-adapter dpg-mcc-3240-15-a2:0c fc1/30 F-port 201e547fee78efb0 500a0981009aef40 fcp-adapter dpg-mcc-3240-15-a1:0d Last Update Time: 7/31/2014 14:26:48 -04:00 Path: Switch Port Node Adapter Switch Port Speed Adapter Type -------------------- -------------- ----------- ------- -------------- dpg-mcc-3240-15-a1 0d fc1/30 4Gbps FCP-Initiator dpg-mcc-3240-15-a1 fcvi_device_1 fc1/27 8Gbps FC-VI dpg-mcc-3240-15-a2 0c fc1/29 4Gbps FCP-Initiator dpg-mcc-3240-15-a2 fcvi_device_1 fc1/28 8Gbps FC-VI
The following command displays cooling (temperature sensors and fans) information about all back-end FC switches:
cluster::> system switch fibre-channel show -cooling Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:26:58 -04:00 Fans: Fan RPM Status ------------ -------- --------------- Fan Module-1 - operational Fan Module-2 operational Fan Module-3 operational Fan Module-4 operational Last Update Time: 7/31/2014 14:27:10 -04:00 Temperature Sensors: Sensor Temp (C) Status --------------- -------- -------- module-1 Outlet 27 normal module-1 Outlet 29 normal module-1 Intake 26 normal module-1 Intake 28 normal
The following command displays the error information about all back-end FC switches:
cluster::> system switch fibre-channel show -error Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 ------------------------------------------------------------------------------- Cisco_10.226.197.34(2000547fee78f088): Switch is Unreachable over Management Network. Switch Name: Cisco_10.226.197.35 Switch WWN: 2000547fee78f0f0 ------------------------------------------------------------------------------- Cisco_10.226.197.35(2000547fee78f0f0): Switch is Unreachable over Management Network. Switch Name: Cisco_10.226.197.36 Switch WWN: 2000547fee78efb0 ------------------------------------------------------------------------------- Cisco_10.226.197.36(2000547fee78efb0): Switch is Unreachable over Management Network. Switch Name: Cisco_10.226.197.37 Switch WWN: 2000547fee78f0d8 ------------------------------------------------------------------------------- Cisco_10.226.197.37(2000547fee78f0d8): Switch is Unreachable over Management Network. 4 entries were displayed.
The following command displays the detailed information about all the back-end FC switches:
cluster::> system switch fibre-channel show -instance Switch Name: Cisco_10.226.197.34 Switch Domain: - Switch Role: - Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Firmware Version: 6.2(1) Management IP: 10.226.197.34 Errors: Cisco_10.226.197.34(2000547fee78f088): Switch is Unreachable over Management Network. Last Update Time: 7/31/2014 14:41:28 -04:00 Fabric: Switch Name Domain WWN Role IP Address --------------------------- ------ ---------------- ----------- --------------- Cisco_10.226.197.34 0 2000547fee78f088 unknown 10.226.197.34 Cisco_10.226.197.36 0 2000547fee78efb0 unknown 10.226.197.36
The following command displays port information about all back-end FC switches:
cluster::> system switch fibre-channel show -port Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:26:58 -04:00 Ports: Admin Oper SFP Speed BB Port Name Port WWN Status Status Port Mode Present (Gbps) Credit PeerPortWWN --------- -------- -------- ------- --------- ------- ------ ------ ----------- fc1/1 2001547fee78f088 enabled online F-port true 8 1 2100001086608b76 fc1/2 2002547fee78f088 enabled offline auto true 0 1 fc1/3 2003547fee78f088 enabled online F-port true 8 1 21000024ff48edd9 fc1/4 2004547fee78f088 enabled online F-port true 8 1 21000024ff3dd981 fc1/5 2005547fee78f088 enabled online F-port true 4 1 500a098001057f98 fc1/6 2006547fee78f088 enabled online F-port true 4 1 500a098101069778 fc1/7 2007547fee78f088 enabled offline auto true 0 1 fc1/8 2008547fee78f088 enabled offline auto true 0 1 fc1/9 2009547fee78f088 enabled offline auto true 0 1 fc1/10 200a547fee78f088 enabled offline auto true 0 32 fc1/11 200b547fee78f088 enabled offline TE-port true 8 32 200b547fee78efb0 fc1/12 200c547fee78f088 enabled offline TE-port true 8 32 200c547fee78efb0 fc1/13 200d547fee78f088 enabled online F-port true 8 32 2100001086609c2e fc1/14 200e547fee78f088 enabled offline auto true 0 32 fc1/15 200f547fee78f088 enabled offline auto true 0 32 fc1/16 2010547fee78f088 enabled offline auto true 0 32 fc1/17 2011547fee78f088 enabled offline auto true 0 32 fc1/18 2012547fee78f088 enabled offline auto true 0 32 fc1/19 2013547fee78f088 enabled offline auto true 0 32 fc1/20 2014547fee78f088 enabled offline auto true 0 1 fc1/21 2015547fee78f088 enabled offline auto true 0 1 fc1/22 2016547fee78f088 enabled offline auto true 0 32 fc1/23 2017547fee78f088 enabled offline auto true 0 32 fc1/24 2018547fee78f088 enabled offline auto true 0 32 fc1/25 2019547fee78f088 enabled online F-port true 8 32 2100001086609c06 fc1/26 201a547fee78f088 enabled offline auto true 0 32 fc1/27 201b547fee78f088 enabled online F-port true 8 32 21000024ff48ea93 fc1/28 201c547fee78f088 enabled online F-port true 8 32 21000024ff48eacf fc1/29 201d547fee78f088 enabled online F-port true 4 32 500a098101484340 fc1/30 201e547fee78f088 enabled online F-port true 4 32 500a09810147e700 fc1/31 201f547fee78f088 enabled offline auto true 0 32 fc1/32 2020547fee78f088 enabled offline auto true 0 1 fc1/33 2021547fee78f088 enabled offline auto true 0 1 fc1/34 2022547fee78f088 enabled offline auto true 0 32 fc1/35 2023547fee78f088 enabled offline auto true 0 32 fc1/36 2024547fee78f088 enabled offline auto true 0 32 fc1/37 2025547fee78f088 enabled offline auto true 0 32 fc1/38 2026547fee78f088 enabled offline auto true 0 32 fc1/39 2027547fee78f088 enabled offline auto true 0 32 fc1/40 2028547fee78f088 enabled offline auto true 0 32 fc1/41 2029547fee78f088 enabled offline auto true 0 32 fc1/42 202a547fee78f088 enabled offline auto true 0 32 fc1/43 202b547fee78f088 enabled offline auto true 0 32 fc1/44 202c547fee78f088 enabled offline auto true 0 32 fc1/45 202d547fee78f088 enabled offline auto true 0 32 fc1/46 202e547fee78f088 enabled offline auto true 0 32 fc1/47 202f547fee78f088 enabled offline auto true 0 32 fc1/48 2030547fee78f088 enabled offline auto true 0 0 port-channel 1 2401547fee78f088 enabled offline auto true 0 0 port-channel 2 2402547fee78f088 enabled offline auto true 0 0 port-channel 3 2403547fee78f088 enabled offline auto true 0 0 port-channel 4 2404547fee78f088 enabled offline auto true 0 0 port-channel 5 2405547fee78f088 enabled offline auto true 0 0 port-channel 6 2406547fee78f088 enabled offline auto true 0 0 port-channel 7 2407547fee78f088 enabled offline auto true 0 0 port-channel 8 2408547fee78f088 enabled offline auto true 0 0 port-channel 9 2409547fee78f088 enabled offline auto true 0 0 port-channel 10 240a547fee78f088 enabled offline auto true 0 0 port-channel 11 240b547fee78f088 enabled offline auto true 0 0 port-channel 12 240c547fee78f088 enabled offline auto true 0 0 sup-fc0 enabled online unknown true 1 0
The following command displays power supply unit information about all back-end FC switches:
cluster::> system switch fibre-channel show -power Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:41:49 -04:00 Power Supplies: Power Supply Serial Number Status --------------- ------------- ----------- 300.00W 110v AC PAC15494TBZ normal 300.00W 110v AC PAC15494T4D normal
The following command displays san configuration (VSANs and Zones) information about all back-end FC switches:
cluster::> system switch fibre-channel show -san-config Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:41:49 -04:00 VSAN Configuration: Oper VSAN ID Vsan Name Status Load Balancing isIOD ------- ------------------------ ------ --------------- ----- 1 VSAN0001 up src-id-dest-id true 2 dpg_13_storage up src-id-dest-id-ox-id true 3 dpg_13_fcvi down src-id-dest-id-ox-id true 10 dpg_mcc_13_fab1_fcvi up src-id-dest-id true 20 dpg_mcc_13_fab1_storage up src-id-dest-id-ox-id true 30 dpg_mcc_13_fab2_fcvi up src-id-dest-id true 40 VSAN0040 up src-id-dest-id true 70 dpg_mcc_14_fcvi up src-id-dest-id true 80 dpg_mcc_14_storage up src-id-dest-id-ox-id true 110 dpg_mcc_15_fcvi up src-id-dest-id-ox-id true 120 dpg_mcc_15_storage up src-id-dest-id-ox-id true 4094 isolated_vsan down src-id-dest-id-ox-id true VSAN Membership: VSAN ID Switch Name Switch Port Name ------- -------------------- ---------------- 1 Cisco_10.226.197.34 fc1/2 1 Cisco_10.226.197.34 fc1/7 1 Cisco_10.226.197.34 fc1/8 1 Cisco_10.226.197.34 fc1/9 1 Cisco_10.226.197.34 fc1/10 1 Cisco_10.226.197.34 fc1/11 1 Cisco_10.226.197.34 fc1/12 1 Cisco_10.226.197.34 fc1/14 1 Cisco_10.226.197.34 fc1/19 1 Cisco_10.226.197.34 fc1/20 1 Cisco_10.226.197.34 fc1/21 1 Cisco_10.226.197.34 fc1/22 1 Cisco_10.226.197.34 fc1/23 1 Cisco_10.226.197.34 fc1/24 1 Cisco_10.226.197.34 fc1/31 1 Cisco_10.226.197.34 fc1/32 1 Cisco_10.226.197.34 fc1/33 1 Cisco_10.226.197.34 fc1/34 1 Cisco_10.226.197.34 fc1/35 1 Cisco_10.226.197.34 fc1/36 1 Cisco_10.226.197.34 fc1/37 1 Cisco_10.226.197.34 fc1/38 1 Cisco_10.226.197.34 fc1/39 1 Cisco_10.226.197.34 fc1/40 1 Cisco_10.226.197.34 fc1/41 1 Cisco_10.226.197.34 fc1/42 1 Cisco_10.226.197.34 fc1/43 1 Cisco_10.226.197.34 fc1/44 1 Cisco_10.226.197.34 fc1/45 1 Cisco_10.226.197.34 fc1/46 1 Cisco_10.226.197.34 fc1/47 1 Cisco_10.226.197.34 fc1/48 1 Cisco_10.226.197.34 port-channel 1 1 Cisco_10.226.197.34 port-channel 2 1 Cisco_10.226.197.34 port-channel 3 1 Cisco_10.226.197.34 port-channel 4 1 Cisco_10.226.197.34 port-channel 5 1 Cisco_10.226.197.34 port-channel 6 1 Cisco_10.226.197.34 port-channel 7 1 Cisco_10.226.197.34 port-channel 8 1 Cisco_10.226.197.34 port-channel 9 1 Cisco_10.226.197.34 port-channel 10 1 Cisco_10.226.197.34 port-channel 11 1 Cisco_10.226.197.34 port-channel 12 1 Cisco_10.226.197.36 fc1/2 1 Cisco_10.226.197.36 fc1/7 1 Cisco_10.226.197.36 fc1/8 1 Cisco_10.226.197.36 fc1/9 1 Cisco_10.226.197.36 fc1/10 1 Cisco_10.226.197.36 fc1/11 1 Cisco_10.226.197.36 fc1/12 1 Cisco_10.226.197.36 fc1/14 1 Cisco_10.226.197.36 fc1/19 1 Cisco_10.226.197.36 fc1/20 1 Cisco_10.226.197.36 fc1/21 1 Cisco_10.226.197.36 fc1/22 1 Cisco_10.226.197.36 fc1/23 1 Cisco_10.226.197.36 fc1/24 1 Cisco_10.226.197.36 fc1/26 1 Cisco_10.226.197.36 fc1/31 1 Cisco_10.226.197.36 fc1/32 1 Cisco_10.226.197.36 fc1/33 1 Cisco_10.226.197.36 fc1/34 1 Cisco_10.226.197.36 fc1/35 1 Cisco_10.226.197.36 fc1/36 1 Cisco_10.226.197.36 fc1/37 1 Cisco_10.226.197.36 fc1/38 1 Cisco_10.226.197.36 fc1/39 1 Cisco_10.226.197.36 fc1/40 1 Cisco_10.226.197.36 fc1/41 1 Cisco_10.226.197.36 fc1/42 1 Cisco_10.226.197.36 fc1/43 1 Cisco_10.226.197.36 fc1/44 1 Cisco_10.226.197.36 fc1/45 1 Cisco_10.226.197.36 fc1/46 1 Cisco_10.226.197.36 fc1/47 1 Cisco_10.226.197.36 fc1/48 30 Cisco_10.226.197.34 fc1/3 30 Cisco_10.226.197.34 fc1/4 30 Cisco_10.226.197.36 fc1/3 30 Cisco_10.226.197.36 fc1/4 40 Cisco_10.226.197.34 fc1/1 40 Cisco_10.226.197.34 fc1/5 40 Cisco_10.226.197.34 fc1/6 40 Cisco_10.226.197.36 fc1/1 40 Cisco_10.226.197.36 fc1/5 40 Cisco_10.226.197.36 fc1/6 70 Cisco_10.226.197.34 fc1/15 70 Cisco_10.226.197.34 fc1/16 70 Cisco_10.226.197.36 fc1/15 70 Cisco_10.226.197.36 fc1/16 80 Cisco_10.226.197.34 fc1/13 80 Cisco_10.226.197.34 fc1/17 80 Cisco_10.226.197.34 fc1/18 80 Cisco_10.226.197.36 fc1/13 80 Cisco_10.226.197.36 fc1/17 80 Cisco_10.226.197.36 fc1/18 110 Cisco_10.226.197.34 fc1/26 110 Cisco_10.226.197.34 fc1/27 110 Cisco_10.226.197.34 fc1/28 120 Cisco_10.226.197.34 fc1/25 120 Cisco_10.226.197.34 fc1/29 120 Cisco_10.226.197.34 fc1/30 120 Cisco_10.226.197.36 fc1/25 120 Cisco_10.226.197.36 fc1/29 120 Cisco_10.226.197.36 fc1/30 Last Update Time: 7/31/2014 14:45:40 -04:00 Zone Configuration: Member Member Member Zone Name VSAN ID Switch Name Port Name Port ID Member WWN --------- ------- ----------- --------- ------- ---------- dpg_mcc_fcvi 30 Cisco_10.226.197.36 fc1/3 - $default_zone$ 30 Cisco_10.226.197.36 fc1/4 dpg_mcc_storage 40 Cisco_10.226.197.36 fc1/1 $default_zone$ 40 Cisco_10.226.197.36 fc1/5 dpg_mcc_14_fcvi 70 Cisco_10.226.197.36 fc1/15 $default_zone$ 70 Cisco_10.226.197.36 fc1/16 dpg_mcc_14_storage 80 Cisco_10.226.197.34 fc1/13 $default_zone$ 80 Cisco_10.226.197.34 fc1/17 dpg_mcc_15_fcvi 110 Cisco_10.226.197.36 fc1/27 $default_zone$ 110 Cisco_10.226.197.36 fc1/28 dpg_mcc_15_storage 120 Cisco_10.226.197.34 fc1/25 $default_zone$ 120 Cisco_10.226.197.34 fc1/29
The following command displays port SFP information about all back-end FC switches:
cluster::> system switch fibre-channel show -sfp Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:41:49 -04:00 SFP: Port Name Type Tx Type Vendor Part Number Serial Number --------- ------------- ---------------- ----------- ----------- ------------- fc1/1 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629J9 fc1/2 unknown unknown fc1/3 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629H3 fc1/4 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629QH fc1/5 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160628EA fc1/6 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629QT fc1/7 unknown unknown fc1/8 unknown unknown fc1/9 unknown unknown fc1/10 unknown unknown fc1/11 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629GP fc1/12 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061X71 fc1/13 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629P8 fc1/14 unknown unknown fc1/15 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629JP fc1/16 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160628D2 fc1/17 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629NG fc1/18 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629R1 fc1/19 unknown unknown fc1/20 unknown unknown fc1/21 unknown unknown fc1/22 unknown unknown fc1/23 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629NC fc1/24 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160628CX fc1/25 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629NZ fc1/26 unknown unknown fc1/27 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061XB0 fc1/28 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061XA6 fc1/29 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061XA0 fc1/30 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061X9S fc1/31 unknown unknown fc1/32 unknown unknown fc1/33 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS16061NL7 fc1/34 unknown unknown fc1/35 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629M8 fc1/36 sfp-with-serial-id short-wave-laser CISCO-FINISAR FTLF8528P2BCV-CS FNS160629KH fc1/37 unknown unknown fc1/38 unknown unknown fc1/39 unknown unknown fc1/40 unknown unknown fc1/41 unknown unknown fc1/42 unknown unknown fc1/43 unknown unknown fc1/44 unknown unknown fc1/45 unknown unknown fc1/46 unknown unknown fc1/47 unknown unknown fc1/48 unknown unknown port-channel 1 unknown unknown port-channel 2 unknown unknown port-channel 3 unknown unknown port-channel 4 unknown unknown port-channel 5 unknown unknown port-channel 6 unknown unknown port-channel 7 unknown unknown port-channel 8 unknown unknown port-channel 9 unknown unknown port-channel 10 unknown unknown port-channel 11 unknown unknown port-channel 12 unknown unknown sup-fc0
The following command displays port statistics information about all back-end FC switches:
cluster::> system switch fibre-channel show -stats Switch Name: Cisco_10.226.197.34 Switch WWN: 2000547fee78f088 Fabric WWN: 2001547fee78efb1 Vendor: Cisco Model: DS-C9148-16P-K9 Errors: - Last Update Time: 7/31/2014 14:41:49 -04:00 Port Statistics: Rx Rx Tx Tx Error Port Name Frames Octets Frames Octets Frames ------------ ------------ ------------ ------------ ------------ ------------ fc1/1 2116207233 3710682580 3906335374 859905888 0 fc1/2 1 208 1 208 0 fc1/3 3238899002 903116292 3079548736 4014304952 0 fc1/4 1888758418 1643379900 2434821325 2997002344 0 fc1/5 3719731908 1808138824 1878240211 3421335100 0 fc1/6 2644430347 1042009564 249190625 2003353056 0 fc1/7 1 228 1 228 0 fc1/8 1 156 1 156 0 fc1/9 1 148 1 148 0 fc1/10 1 224 1 224 0 fc1/11 3617142898 4129927136 39089396 2595464620 0 fc1/12 473603889 1560909460 2797562521 2833496016 0 fc1/13 1852255936 1091902804 180309704 1769859928 0 fc1/14 1 140 1 140 0 fc1/15 4997082 3519688264 4283938 3370856432 0 fc1/16 4995287 3519577592 4282173 3370732136 0 fc1/17 55146756 178045212 1733567096 3030415436 0 fc1/18 63005788 4287094736 1726651844 2640371212 0 fc1/19 1 200 1 200 0 fc1/20 1 104 1 104 0 fc1/21 1 108 1 108 0 fc1/22 1 108 1 108 0 fc1/23 1 164 1 164 0 fc1/24 1 216 1 216 0 fc1/25 2810698819 1611009260 471527156 1900246656 0 fc1/26 1 104 1 104 0 fc1/27 4165019838 887421780 3848122102 2581891136 0 fc1/28 58607737 1015197080 101621078 3482734024 0 fc1/29 4266270960 222242144 3766674764 2400640552 0 fc1/30 3984658378 1443835508 152597387 678837848 0 fc1/31 1 220 1 220 0 fc1/32 1 120 1 120 0 fc1/33 1 132 1 132 0 fc1/34 1 144 1 144 0 fc1/35 1 160 1 160 0 fc1/36 1 104 1 104 0 fc1/37 1 148 1 148 0 fc1/38 1 184 1 184 0 fc1/39 1 160 1 160 0 fc1/40 1 136 1 136 0 fc1/41 1 196 1 196 0 fc1/42 1 128 1 128 0 fc1/43 1 168 1 168 0 fc1/44 1 212 1 212 0 fc1/45 1 136 1 136 0 fc1/46 1 224 1 224 0 fc1/47 1 104 1 104 0 fc1/48 1 104 1 104 0