ONTAP 9.12.1 commands

50←PDF
  • ONTAP 9.12.1 commands(CA08871-263en.pdf)
  • storage failover mailbox-disk show

    Display information about storage failover mailbox disks

    Availability: This command is available to cluster administrators at the advanced privilege level.

    Description

    The storage failover mailbox-disk show command lists the mailbox disks that are used by storage failover. The command displays the following information:

    • Node name

    • Whether the mailbox disk is owned by the local node or by its partner

    • Disk name

    • Disk universal unique identifier (UUID)

    This command is available only at the advanced privilege level and higher.

    Parameters

    { [-fields <fieldname>,…​]

    If -fields <fieldname>,…​ is used, the command displays only the specified fields.

    | [-instance ] }

    If this parameter is used, the command displays detailed information about all entries.

    [-node {<nodename>|local}] - Node

    Selects the mailbox disks that are associated with the specified node.

    [-location {local|partner|tertiary}] - Mailbox Owner

    Selects the mailbox disks that have the specified relationship to the node.

    [-diskindex <integer>] - Mailbox Disk Index

    Selects the mailbox disk that has the specified index number.

    [-diskname <text>] - Mailbox Disk Name

    Selects the mailbox disks that match the specified disk name.

    [-diskuuid <text>] - Mailbox Disk UUID

    Selects the mailbox disks that match the specified UUID.

    [-physical-location {local|partner|mediator}] - Mailbox Disk Physical Location

    Selects the mailbox disks that match the specified physical location.

    [-location-id <nvramid>] - System ID of the Node where the Disk is Attached

    Selects the mailbox disks that match the specified location-id.

    [-location-name <text>] - Mailbox Disk Location

    Selects the mailbox disks that match the specified location-name.

    Examples

    The following example displays information about the mailbox disks on a node named node1:

    cluster1::*> storage failover mailbox-disk show -node node1
    Node    Location  Index Disk Name     Physical Location   Disk UUID
    ------- --------- ----- ------------- ------------------ --------------------
    node1
            local         0 1.0.4         local     20000000:8777E9D6:[...]
            local         1 1.0.6         partner     20000000:8777E9DE:[...]
            partner       0 1.0.1         local     20000000:877BA634:[...]
      partner       1 1.0.2         partner     20000000:8777C1F2:[...]
    Top of Page