ONTAP 9.12.1 commands

50←PDF
  • ONTAP 9.12.1 commands(CA08871-263en.pdf)
  • system ha interconnect status show

    Display the high-availability interconnect connection status

    Availability: This command is available to cluster administrators at the advanced privilege level.

    Description

    The system ha interconnect status show command displays the high-availability interconnect connection status. Connection status information displayed by this command varies by controller model. For nodes with two HA interconnect links over the backplane or connected externally, this command displays the following information:

    • Node

    • Link status on the first port

    • Link status on the second port

    • Is the link on first port active?

    • Is the link on second port active?

    • Interconnect RDMA status

    For nodes with a single HA interconnect link, this command displays following the information:

    • Node

    • Link status

    • Interconnect RDMA status

    Running the command with the -instance or -node parameter displays detailed information about the interconnect device and its ports.

    Parameters

    { [-fields <fieldname>,…​]

    If you specify the -fields <fieldname>,…​ parameter, the command displays only the fields that you specify.

    | [-instance ] }

    Use this parameter to display all the fields for the specified node or all the nodes.

    [-node {<nodename>|local}] - Node

    Use this parameter to display all the fields for the specified node.

    [-link-status {up|down}] - Link Status

    Selects the nodes that match this parameter value. The value up means link is online.

    [-link0-status {up|down}] - Link 0 Status

    Selects the nodes that match this parameter value. The value up means link is online.

    [-link1-status {up|down}] - Link 1 Status

    Selects the nodes that match this parameter value. The value up means link is online.

    [-ic-rdma {up|down}] - IC RDMA Connection

    Selects the nodes that match this parameter value. The value up means active interconnect connection with its partner.

    [-is-link0-active {true|false}] - Is Link 0 Active

    Selects the nodes that match this parameter value. The value true means the interconnect data channels are established on this link.

    [-is-link1-active {true|false}] - Is Link 1 Active

    Selects the nodes that match this parameter value. The value true means the interconnect data channels are established on this link.

    [-slot <integer>] - Slot Number

    Selects the nodes that match this PCI slot number.

    [-driver-name <text>] - Driver Name

    Selects the nodes that match this interconnect device driver name.

    [-firmware <text>] - Firmware Revision

    Selects the nodes that match this firmware version.

    [-version <text>] - Version Number

    Selects the nodes that match this parameter value.

    [-device-type <text>] - Device Type

    Selects the nodes that match this interconnect device type.

    [-serial-number <text>] - Serial Number

    Selects the nodes that match this interconnect device serial number.

    [-debug-firmware {yes|no}] - Debug Firmware

    Selects the nodes that match this parameter value.

    [-command-revision <integer>] - Command Revision

    Selects the nodes that match this interconnect device command revision.

    [-hardware-revision <integer>] - Hardware Revision

    Selects the nodes that match this interconnect device hardware revision.

    [-port1 <integer>] - Port Number 1

    Selects the nodes that match this parameter value.

    [-port1-port-name <text>] - Port Name

    Selects the nodes that match this port name.

    [-port1-gid <text>] - Global Identifier

    Selects the nodes that match this global identifier value.

    [-port1-base-lid <text>] - Base Local Identifier

    Selects the nodes that match this base local identifier value.

    [-port1-rm-lid <text>] - Remote Local Identifier

    Selects the nodes that match this remote local identifier value.

    [-port1-mtu <integer>] - Maximum Transmission Unit

    Selects the nodes that match this parameter value.

    [-port1-data-rate <text>] - Data Rate

    Selects the nodes that match this parameter value.

    [-port1-link-info <text>] - Link Information

    Selects the nodes that match this parameter value.

    [-port1-qsfp-vendor <text>] - QSFP Vendor

    Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) vendor name.

    [-port1-qsfp-part-number <text>] - QSFP Part Number

    Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) part-number.

    [-port1-qsfp-type <text>] - QSFP Type

    Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) type.

    [-port1-qsfp-serial-number <text>] - QSFP Serial Number

    Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) serial number.

    [-port2 <integer>] - Port Number 2

    Selects the nodes that match this parameter value.

    [-port2-port-name <text>] - Port Name

    Selects the nodes that match this port name.

    [-port2-gid <text>] - Global Identifier

    Selects the nodes that match this global identifier value.

    [-port2-base-lid <text>] - Base Local Identifier

    Selects the nodes that match this base local identifier value.

    [-port2-rm-lid <text>] - Remote Local Identifier

    Selects the nodes that match this remote local identifier value.

    [-port2-mtu <integer>] - Maximum Transmission Unit

    Selects the nodes that match this parameter value.

    [-port2-data-rate <text>] - Data Rate

    Selects the nodes that match this parameter value.

    [-port2-link-info <text>] - Link Information

    Selects the nodes that match this parameter value.

    [-port2-qsfp-vendor <text>] - QSFP Vendor

    Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) vendor name.

    [-port2-qsfp-part-number <text>] - QSFP Part Number

    Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) part number.

    [-port2-qsfp-type <text>] - QSFP Type

    Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) type.

    [-port2-qsfp-serial-number <text>] - QSFP Serial Number

    Selects the nodes that match this QSFP (Quad Small Form-factor Pluggable) serial number.

    Examples

    The following example displays status information about the HA interconnect connection on FAS8000 series nodes with two HA interconnect links in the cluster:

    cluster1::*> system ha interconnect status show
    Node: ic-f8040-01
                  Link 0 Status: up
                  Link 1 Status: up
               Is Link 0 Active: true
               Is Link 1 Active: false
             IC RDMA Connection: up
    Node: ic-f8040-02
                  Link 0 Status: up
                  Link 1 Status: up
               Is Link 0 Active: true
               Is Link 1 Active: false
             IC RDMA Connection: up
    2 entries were displayed.

    The following example displays status information about the HA interconnect connection on FAS2500 series nodes with a single HA interconnect link in the cluster:

    cluster1::*> system ha interconnect status show
    Node: ic-f2554-01
                    Link Status: up
             IC RDMA Connection: up
    Node: ic-f2554-02
                    Link Status: up
             IC RDMA Connection: up
    2 entries were displayed.

    The following example displays detailed information about the HA interconnect link when parameters like -instance , -node are used with the `system ha interconnect status show ` command

    cluster1::*> system ha interconnect status show -instance -node ic-f8040-01
    Node: ic-f8040-01
                  Link 0 Status: up
                  Link 1 Status: up
               Is Link 0 Active: true
               Is Link 1 Active: false
             IC RDMA Connection: up
                           Slot: 0
                    Driver Name: IB Host Adapter i0 (Mellanox ConnectX MT27518 rev. 0)
                       Firmware: 2.11.534
                 Debug Firmware: no
    
    Interconnect Port 0 :
                      Port Name: ib0a
                            GID: fe80:0000:0000:0000:00a0:9800:0030:33ec
                       Base LID: 0x3ec
                            MTU: 4096
                      Data Rate: 40 Gb/s (4X) QDR
               Link Information: ACTIVE
    
    Interconnect Port 1 :
                      Port Name: ib0b
                            GID: fe80:0000:0000:0000:00a0:9800:0030:33ed
                       Base LID: 0x3ed
                            MTU: 4096
                      Data Rate: 40 Gb/s (4X) QDR
               Link Information: ACTIVE
    Top of Page