ONTAP 9.12.1 commands

50←PDF
  • ONTAP 9.12.1 commands(CA08871-263en.pdf)
  • system controller config show-errors

    Display configuration errors

    Availability: This command is available to cluster administrators at the admin privilege level.

    Description

    The system controller config show-errors displays configuration errors.

    • node

    • description

    To display more details, use the -instance parameter.

    Parameters

    { [-fields <fieldname>,…​]

    Selects the fields that you specify.

    | [-instance ] }

    Displays detailed information for all the PCI devices.

    [-node {<nodename>|local}] - Node

    Displays configuration errors on the specified node.

    [-verbose <true>] - Verbose Output?

    The -verbose parameter enables verbose mode, resulting in the display of more detailed output.

    [-description <text>] - Error Description

    Displays the node with the specified configuration error.

    Examples

    The example below displays configuration errors on all the nodes in the cluster.

    cluster1::> system controller config show-errors
    
    Configuration Info and Errors for Node: cluster1-01
    ------------------------------------------------------------------------------
    Chelsio T320E 2x10G NIC card (PN X1008A) in slot 1 is not supported on model FAS3210
    
    Configuration Info and Errors for Node: cluster1-02
    ------------------------------------------------------------------------------
    PCI-E Dual 10/100/1000 Ethernet G20 card (PN X1039A) in slot 2 is not supported on model FAS3210
    
    cluster1::>
    
    cluster1::> system controller config show-errors -verbose
    
    Configuration Info and Errors for Node: cluster1-01
    ------------------------------------------------------------------------------
    sysconfig: Card in slot 2 (7-1275-0008-46848) is not supported.
    sysconfig: slot 12 OK: X2067: Proprietary embedded SAS HBA
    
    cluster1::>
    Top of Page