ONTAP 9.12.1 commands

50←PDF
  • ONTAP 9.12.1 commands(CA08871-263en.pdf)
  • storage shelf show

    Display a list of storage shelves

    Availability: This command is available to cluster administrators at the admin privilege level.

    Description

    The storage shelf show command displays information about all the storage shelves in the storage system. If no parameters are specified, the default command displays the following information about the storage shelves:

    • Shelf Name

    • Shelf ID

    • Serial Number

    • Model

    • Module Type

    • Status

    To display detailed profile information about a single storage shelf, use the -shelf parameter.

    Parameters

    { [-fields <fieldname>,…​]

    Displays the specified fields for all the storage shelves, in column style output.

    | [-bay ]

    Displays the following details about the disk bays in the storage shelf:

    • The unique positional identifier of the disk bay

    • Whether a disk drive is installed in the bay

    • Bay type

    • Operational status of the disk bay

    | [-connectivity ]

    Displays the following details about the connectivity from the node to the storage shelf:

    • Node name

    • Initiator side switch port

    • Target side switch port

    • World-wide port name

    • Target Port Group Number (TPGN)

    | [-cooling ]

    Displays the following details about the cooling elements and temperature sensors of the storage shelf:

    • Element ID of the cooling fan

    • The current speed of the cooling fan in revolutions per minute (rpm)

    • Operational status of the cooling fan

    • Sensor ID of the temperature sensor element

    • Temperature at the sensor in degrees Celsius

    • Whether the current temperature at the sensor is the ambient temperature

    • Low critical threshold value for the temperature sensor

    • Low warning threshold value for the temperature sensor

    • High critical threshold value for the temperature sensor

    • High warning threshold value for the temperature sensor

    • Operational status for the temperature sensor

    | [-errors ]

    Displays the following error status information about the storage shelves that have errors:

    • Error type

    • Error description

    | [-module ]

    Displays the following details about the I/O modules attached to the storage shelf:

    • Module ID

    • Module part number

    • Serial number of the Enclosure Services Controller Electronics element

    • Whether monitoring is enabled on this module

    • Whether this module is the SAS expander master module

    • Whether this module is the element reporting

    • Version of the firmware installed on the module

    • Latest firmware revision

    • Number of times, since the last boot, that this module has been swapped

    • Operational status of the module

    | [-port ]

    Displays the following details about the storage shelf ports:

    • Expander phy element identifier

    • SAS shelf port type

    • World-wide Port Name of the SAS port

    • Operational physical link rate of the SAS port in Gb/s

    • Negotiated physical link rate of the SAS port in Gb/s

    • Power status of the SAS port

    • Status of the SAS port

    • Fibre Channel shelf port ID

    • Fibre Channel shelf port type

    • Fibre Channel shelf port status

    | [-power ]

    Displays the following details about the power supplies, voltage sensors, and current sensors of the storage shelf:

    • Power Supply Unit (PSU) number

    • PSU type

    • PSU part number

    • PSU serial number

    • PSU power rating in watts

    • PSU crest factor

    • Power drawn from the PSU in watts

    • Whether the PSU can be reset via software control

    • Whether the auto power reset of the PSU is enabled

    • PSU firmware revision

    • Operational status of the PSU

    • Voltage sensor number

    • Voltage detected by the voltage sensor, in volts (V)

    • Operational status of the voltage sensor

    • Current sensor number

    • Current detected by the current sensor, in milliamps (mA)

    • Operational status of the current sensor

    | [-instance ]

    Displays expanded information about all the storage shelves in the system.

    [-shelf <text>] - Shelf Name

    Displays information only about the storage shelves that match the names you specify.

    [-node {<nodename>|local}] - Node

    Displays information only about the storage shelves that are attached to the node you specify.

    [-shelf-uid <text>] - Shelf UID

    Displays information only about the storage shelf that matches the shelf UID you specify. Example: `50:05:0c:c0:02:10:64:26 `

    [-stack-id {<integer>|-}] - Stack ID

    Displays information only about the storage shelves that are attached to the stack that matches the stack ID you specify

    [-shelf-id <text>] - Shelf ID

    Displays information only about the storage shelves that match the shelf ID you specify.

    [-module-type {unknown|atfcx|esh4|iom3|iom6|iom6e|iom12|iom12e|iom12f|nsm100|nsm8e|psm3e|iom12b|iom12g}] - Shelf Module Type

    Displays information only about the storage shelves that match the module-type you specify.

    [-connection-type {unknown|fc|sas|nvme}] - Shelf Connection Type

    Displays information only about the storage shelves that match the connection type you specify. Example: FC or SAS.

    [-is-local-attach {true|false}] - Is the Shelf Local to This Cluster?

    Displays information only about the storage shelves that are local (TRUE) or remote (FALSE) to this cluster.

    [-vendor <text>] - Shelf Vendor

    Displays information only about the storage shelves that match the vendor you specify.

    [-product-id <text>] - Shelf Product Identification

    Displays information only about the storage shelves that match the product ID you specify.

    [-serial-number <text>] - Shelf Serial Number

    Displays information only about the storage shelf that matches the serial number you specify.

    [-disk-count {<integer>|-}] - Disk Count

    Displays information only about the storage shelves that have the disk count you specify.

    [-state {unknown|no-status|init-required|online|offline|missing}] - Shelf State

    Displays information only about the storage shelves that are in the state you specify.

    [-op-status {unknown|normal|warning|error|critical|standby-power}] - Shelf Operational Status

    Displays information only about the storage shelves that are currently operating under the status condition you specify.

    [-bay-id {<integer>|-}] - Bay ID

    Displays information only about the storage shelves that have bays that match the bay ID you specify.

    [-bay-type {unknown|single-disk|multi-lun}] - Bay Type

    Displays information only about the storage shelves that have bays that match the type of bay you specify.

    [-bay-has-disk {true|false}] - Bay Has Disk

    Displays information only about the storage shelves that have bays with disk drives inserted in them (true) or empty bays (false).

    [-bay-op-status {unknown|normal|error}] - Bay Operational Status

    Displays information only about the storage shelves that have bays that match the operational state you specify.

    [-controller {<nodename>|local}] - Controller Name

    Displays information only about the storage shelves that are connected to the node you specify.

    [-controller-uuid <text>,…​] - Controller UUID

    Displays information only about the storage shelves that are connected to the node UUID you specify.

    [-initiator <text>,…​] - Initiator

    Displays information only about the storage shelves that are visible to the initiator you specify.

    [-initiator-wwpn <text>,…​] - Initiator WWPN

    Displays information only about the storage shelves that are visible to the initiator WWPN you specify.

    [-initiator-side-switch-port <text>,…​] - Initiator Side Switch Port

    Displays information only about the storage shelves that are visible to an initiator connected to the switch port you specify.

    [-target-side-switch-port <text>,…​] - Target Side Switch Port

    Displays information only about the storage shelves visible on target ports identified by the switch port to which they are connected.

    [-target-port <text>,…​] - Target Port

    Displays information only about the storage shelves visible on the specified target ports identified by their World-Wide Port Name (WWPN).

    [-tpgn {<integer>|-}] - Target Port Group Number

    Displays information only about the storage shelves that belong to the Target Port Group Name (TPGN) you specify.

    [-port-speed {<integer>|-}] - Port Speed

    Displays information only about the storage shelves with ports that match the port speed you specify.

    [-io-kbps {<integer>|-}] - Kbytes/sec on Storage Shelf

    Displays information only about the storage shelves visible to an initiator that has executed I/O at the throughput you specify.

    [-iops {<integer>|-}] - Number IOPS per Second on Storage Shelf

    Displays information only about the storage shelves visible to an initiator that has executed the number of IOPs you specify.

    [-current-sensor-id {<integer>|-}] - Current Sensor ID

    Displays information only about the storage shelves with current sensor that matches the current sensor ID you specify.

    [-current-sensor-location <text>,…​] - Current Sensor Location

    Displays information only about the storage shelves with current sensors installed at the location you specify.

    [-current-sensor-reading {<integer>|-}] - Current Sensor Reading

    Displays information only about the storage shelves with current sensors that match the current reading you specify.

    [-current-op-status {unknown|normal|over-current-critical|under-current-critical|not-supported|not-installed}] - Operational Status

    Displays information only about the storage shelves with current sensors that match the operational status you specify.

    [-fan-id {<integer>|-}] - Fan ID

    Displays information only about the storage shelves with cooling fans that match the fan IDs you specify.

    [-fan-location <text>,…​] - Fan Location

    Displays information only about the storage shelves with cooling fans installed.

    [-fan-rpm {<integer>|-}] - Fan Rotation Per Minute

    Displays information only about the storage shelves with cooling fans that match the rpm rate you specify.

    [-fan-op-status {unknown|normal|off|error|not-supported|not-installed}] - Fan Operational Status

    Displays information only about the storage shelves with cooling fans that match the operational status you specify.

    [-module-id <text>,…​] - Module ID

    Displays information only about the storage shelves with an I/O module that matches the module ID you specify.

    [-module-location <text>,…​] - Module Location

    Displays information only about the storage shelves with I/O modules in the specified shelf module slots.

    [-module-part-number <text>,…​] - Module Part Number

    Displays information only about the storage shelves with I/O modules that match the module part numbers you specify.

    [-is-sas-master-module {true|false}] - Is SAS Expander Master Module?

    Displays information only about the storage shelves with a SAS master I/O module (true) or an I/O module that is not a SAS master (false). This parameter applies only to SAS shelves.

    [-is-monitor-active {true|false}] - Is Monitor Active?

    Displays information only about the storage shelves whose monitoring is enabled (true) or disabled (false).

    [-enclosure-type <text>,…​] - Module Enclosure Type

    Displays information only about the storage shelves that match the enclosure types you specify.

    [-es-serial-number <text>,…​] - ES Electronics Element Serial Number

    Displays information only about the storage shelves with I/O modules that match the electronics serial numbers you specify.

    [-module-fru-id <text>,…​] - Field Replaceable Unit ID

    Displays information only about the storage shelves with I/O modules that match the field replaceable unit (FRU) IDs you specify.

    [-module-is-reporting-element {true|false}] - Is Reporting Element?

    Displays information only about the storage shelves with element reporting I/O modules (true) or not (false).

    [-module-fw-revision <text>,…​] - Firmware Revision

    Displays information only about the storage shelves with I/O modules that match the firmware revision you specify.

    [-module-latest-fw-revision <text>,…​] - Latest Firmware Revision

    Displays information only about the storage shelves with I/O modules that match the latest firmware revision you specify.

    [-module-fw-progress {not-available|ready|in-progress|failed}] - Module Firmware Progress

    Displays information only about the storage shelves with I/O modules that match the specified firmware update progress.

    [-module-swap-count {<integer>|-}] - Module Swap Count

    Displays information only about the storage shelves whose I/O modules have been swapped the specified number of times.

    [-module-op-status {unknown|normal|warning|error|not-installed}] - Module Operational Status

    Displays information only about the storage shelves with I/O modules that match the operational status you specify.

    [-sas-port-id <text>,…​] - Port ID

    Displays information only about the storage shelves with SAS Ports that match the port IDs you specify.

    [-sas-port-type {unknown|circle|square|sil|disk|in|out|unused|host|dcm|aux1|aux2|hi_ho|a_to_b|b_to_a}] - Port Type

    Displays information only about the storage shelves with SAS Ports that match the SAS port type you specify.

    [-sas-port-wwpn <text>,…​] - Port World Wide Port Name

    Displays information only about the storage shelves with SAS Ports that match the World-Wide Port Names you specify.

    [-sas-port-speed <text>,…​] - Port Speed

    Displays information only about the storage shelves with SAS Ports that match the port speed you specify.

    [-sas-negotiated-port-speed <text>,…​] - Negotiated Port Speed

    Displays information only about the storage shelves with SAS Ports that match the negotiated port speed you specify.

    [-sas-port-power-status <text>,…​] - Port Power Status

    Displays information only about the storage shelves with SAS Ports that match the power status you specify.

    [-sas-port-op-status {error|normal|off|unknown|byp-bad-term|bad-zone-recovery|byp_clk_thr|byp_comma_los|byp_crc_brst_thr|byp_data_timeout|byp_drv_fault|byp_drv_pcycle|byp_drv_pwr|byp_drv_self|byp_gen|byp_init|byp_lip_brst_thr|byp_lip_f8|byp_lip_rate_thr|byp_lipf7|byp_ltbi|byp_man|byp_no_drive|byp_osc|byp_other_thr|byp_rec_los|byp_rport|byp_stall_thr|byp_wrd_brst_thr|byp_wrd_rate_thr|byp_xmit_fault|diag_transmit|inserted|loopback|status_unknown|warn_high_clk_delta|warn_high_crc_rate|warn_high_lip|warn_high_wrd_rate|term|phy_dis_clk_fault|phy_dis_crc_err|phy_dis_crc_err_burst|phy_dis_disparity|phy_dis_disparity_burst|phy_dis_emulate_reserve|phy_dis_inval_dword|phy_dis_inval_dword_burst|phy_dis_loss_dword|phy_dis_loss_dword_burst|phy_dis_man_smp|phy_dis_manual|phy_dis_mirrored|empty|phy_dis_phy_change|phy_dis_phy_change_burst|phy_dis_phy_reset|phy_dis_phy_reset_burst|phy_dis_phy_unused|phy_ena|phy_ena_not_attach|phy_ena_unknown|phy_unknown|phy_dis_illegal}] - Port Operational Status

    Displays information only about the storage shelves with SAS Ports that match the operational status you specify.

    [-sas-port-module-id {A|B}] - Port Module ID

    Displays information only about the storage shelves with SAS Ports that match the module ID you specify.

    [-fc-port-id <text>,…​] - Fibre Channel Port ID

    Displays information only about the storage shelves with FC Ports that match the port IDs you specify.

    [-fc-port-mode {unknown|circle|square|sil|disk|in|out|unused|host|dcm|aux1|aux2|hi_ho|a_to_b|b_to_a}] - Fibre Channel Port Mode

    Displays information only about the storage shelves with FC Ports that match the port modes you specify.

    [-fc-port-op-status {error|normal|off|unknown|byp-bad-term|bad-zone-recovery|byp_clk_thr|byp_comma_los|byp_crc_brst_thr|byp_data_timeout|byp_drv_fault|byp_drv_pcycle|byp_drv_pwr|byp_drv_self|byp_gen|byp_init|byp_lip_brst_thr|byp_lip_f8|byp_lip_rate_thr|byp_lipf7|byp_ltbi|byp_man|byp_no_drive|byp_osc|byp_other_thr|byp_rec_los|byp_rport|byp_stall_thr|byp_wrd_brst_thr|byp_wrd_rate_thr|byp_xmit_fault|diag_transmit|inserted|loopback|status_unknown|warn_high_clk_delta|warn_high_crc_rate|warn_high_lip|warn_high_wrd_rate|term|phy_dis_clk_fault|phy_dis_crc_err|phy_dis_crc_err_burst|phy_dis_disparity|phy_dis_disparity_burst|phy_dis_emulate_reserve|phy_dis_inval_dword|phy_dis_inval_dword_burst|phy_dis_loss_dword|phy_dis_loss_dword_burst|phy_dis_man_smp|phy_dis_manual|phy_dis_mirrored|empty|phy_dis_phy_change|phy_dis_phy_change_burst|phy_dis_phy_reset|phy_dis_phy_reset_burst|phy_dis_phy_unused|phy_ena|phy_ena_not_attach|phy_ena_unknown|phy_unknown|phy_dis_illegal}] - Fibre Channel Port Operational Status

    Displays information only about the storage shelves with FC Ports that match the operational status you specify.

    [-psu-id {<integer>|-}] - Power Supply Unit ID

    Displays information only about the storage shelves with power supply units (PSU) that match the unit IDs you specify.

    [-psu-location <text>,…​] - Power Supply Unit Location

    Displays information only about the storage shelves with PSUs that are located at the specified location inside the shelf.

    [-psu-type <text>,…​] - Power Supply Unit Type

    Displays information only about the storage shelves with PSUs that match the PSU types you specify.

    [-psu-part-number <text>,…​] - Power Supply Unit Part Number

    Displays information only about the storage shelves with PSUs that match the PSU part number you specify.

    [-psu-serial-number <text>,…​] - Power Supply Unit Serial Number

    Displays information only about the storage shelves with PSUs that match the PSU serial numbers you specify.

    [-psu-reset-capable {true|false}] - Power Supply Unit Reset Capability

    Displays information only about the storage shelves with reset capable PSUs (true) or reset incapable PSUs (false).

    [-psu-is-enabled {true|false}] - Power Supply Unit Enable/Disable Status

    Displays information only about the storage shelves with PSUs that are enabled (true) or disabled (false).

    [-psu-fw-version <text>,…​] - Power Supply Unit Firmware Version

    Displays information only about the storage shelves with PSUs that have the firmware version you specify.

    [-psu-op-status {unknown|normal|error|dc-over-voltage|dc-under-voltage|dc-over-current|over-temperature-error|failed|off|not-supported|not-installed}] - Operational Status

    Displays information only about the storage shelves with PSUs that match the operational status you specify.

    [-psu-power-rating {<integer>|-}] - Power Supply Power Ratings In Watts

    Displays information only about the storage shelves with PSUs that match the power rating you specify.

    [-psu-crest-factor {<integer>|-}] - Power Supply Crest Factor

    Displays information only about the storage shelves with PSUs that match the crest factor value you specify.

    [-psu-power-drawn {<integer>|-}] - Power Drawn From PSU In Watts

    Displays information only about the storage shelves with PSUs that match the drawn power you specify.

    [-temp-sensor-id {<integer>|-}] - Sensor Name

    Displays information only about the storage shelves with temperature sensors that match the sensor IDs you specify.

    [-temp-sensor-location <text>,…​] - Sensor Location

    Displays information only about the storage shelves with temperature sensors that match the specified sensor locations inside the shelf.

    [-temp-sensor-reading {<integer>|-}] - Temperature Reading

    Displays information only about the storage shelves with temperature sensors that match the temperature reading you specify.

    [-temp-is-ambient {true|false}] - Temperature Reading at Ambient Value

    Displays information only about the storage shelves with temperature sensors whose current temperature reading is ambient (true) or not (false).

    [-temp-high-critical-threshold {<integer>|-}] - High Critical Threshold

    Displays information only about the storage shelves with temperature sensors that match the high critical threshold you specify.

    [-temp-high-warning-threshold {<integer>|-}] - High Warning Threshold

    Displays information only about the storage shelves with temperature sensors that match the high warning threshold you specify.

    [-temp-low-warning-threshold {<integer>|-}] - Low Warning Threshold

    Displays information only about the storage shelves with temperature sensors that match the low warning threshold you specify.

    [-temp-low-critical-threshold {<integer>|-}] - Low Critical Threshold

    Displays information only about the storage shelves with temperature sensors that match the low critical threshold you specify.

    [-temp-op-status {unknown|normal|under-temperature|over-temperature|error|not-supported|not-installed}] - Operational Status

    Displays information only about the storage shelves with temperature sensors that match the operational status you specify.

    [-voltage-sensor-id {<integer>|-}] - Voltage Sensor ID

    Displays information only about the storage shelves with voltage sens- ors that match the sensor IDs you specify.

    [-voltage-sensor-location <text>,…​] - Voltage Sensor Location

    Displays information only about the storage shelves with voltage sens- ors that match the specified sensor locations inside the shelf.

    [-voltage-sensor-reading <text>,…​] - Voltage Current Reading

    Displays information only about the storage shelves with voltage sens- ors that match the voltage reading you specify.

    [-voltage-op-status {unknown|normal|over-voltage-critical|under-voltage-critical|not-supported|not-installed|not-recoverable}] - Operational Status

    Displays information only about the storage shelves with voltage sens- ors that match the operational status you specify.

    [-nsm-port-module-id {A|B}] - Port Module ID

    Displays information only about the storage shelves with PCIe Ports from the specified module.

    [-nsm-port-id <integer>,…​] - Port ID

    Displays information only about the storage shelves with PCIe Ports that match the specified ID.

    [-nsm-port-type {cpu|disk|cx5|ethernet}] - Port Type

    Displays information only about the storage shelves with PCIe Ports that match the specified type.

    [-nsm-port-state {ok|off-link-disabled|off-dll-link|link-down|no-drive}] - Port State

    Displays information only about the storage shelves with PCIe Ports that match the specified state.

    [-nsm-port-bay <integer>,…​] - Port Bay

    Displays information only about the storage shelves with PCIe Ports that match the specified bay.

    [-nsm-port-disk-id <integer>,…​] - Port Disk ID

    Displays information only about the storage shelves with PCIe Ports that match the specified disk ID.

    [-nsm-port-is-installed {true|false}] - Port Is Disk Installed

    Displays information only about the storage shelves with PCIe Ports that have a disk installed.

    [-nsm-port-is-error {true|false}] - Port Has Error

    Displays information only about the storage shelves with PCIe Ports that have errors.

    [-nsm-port-speed {2.5|5.0|8.0}] - Port Speed

    Displays information only about the storage shelves with PCIe Ports that match the specified speed.

    [-nsm-port-speed-max {2.5|5.0|8.0}] - Max Port Speed

    Displays information only about the storage shelves with PCIe Ports that match the specified maximum speed.

    [-nsm-port-lane-width <integer>,…​] - Port Lane Width

    Displays information only about the storage shelves with PCIe Ports that match the specified lane width.

    [-nsm-port-lane-width-max <integer>,…​] - Max Port Lane Width

    Displays information only about the storage shelves with PCIe Ports that match the specified maximum lane width.

    [-dimm-module-id {A|B}] - DIMM Module ID

    Displays information only about the storage shelves with DIMMs from the specified module.

    [-dimm-id <integer>,…​] - DIMM ID

    Displays information only about the storage shelves with DIMMs that match the specified ID.

    [-dimm-serial-number <text>,…​] - DIMM Serial Number

    Displays information only about the storage shelves with DIMMs that match the specified serial number.

    [-dimm-part-number <text>,…​] - DIMM Part Number

    Displays information only about the storage shelves with DIMMs that match the specified part number.

    [-dimm-vendor <text>,…​] - DIMM Vendor

    Displays information only about the storage shelves with DIMMs that match the specified vendor.

    [-dimm-type <text>,…​] - DIMM Type

    Displays information only about the storage shelves with DIMMs that match the specified type.

    [-dimm-size <text>,…​] - DIMM Size

    Displays information only about the storage shelves with DIMMs that match the specified size.

    [-dimm-speed <text>,…​] - DIMM Speed

    Displays information only about the storage shelves with DIMMs that match the specified speed.

    [-dimm-location <text>,…​] - DIMM Location

    Displays information only about the storage shelves with DIMMs that match the specified location.

    [-dimm-op-status {unknown|normal|error|not-supported|not-installed}] - DIMM Operational Status

    Displays information only about the storage shelves with DIMMs that match the specified operational status.

    [-boot-device-module-id {A|B}] - Boot Device Module ID

    Displays information only about the storage shelves with boot devices from the specified module.

    [-boot-device-id <integer>,…​] - Boot Device ID

    Displays information only about the storage shelves with boot devices that match the specified ID.

    [-boot-device-serial-number <text>,…​] - Boot Device Serial Number

    Displays information only about the storage shelves with boot devices that match the specified serial number.

    [-boot-device-part-number <text>,…​] - Boot Device Part Number

    Displays information only about the storage shelves with boot devices that match the specified part number.

    [-boot-device-vendor <text>,…​] - Boot Device Vendor

    Displays information only about the storage shelves with boot devices that match the specified vendor.

    [-boot-device-type <text>,…​] - Boot Device Type

    Displays information only about the storage shelves with boot devices that match the specified type.

    [-boot-device-size <text>,…​] - Boot Device Size

    Displays information only about the storage shelves with boot devices that match the specified size.

    [-boot-device-op-status {unknown|normal|error|not-supported|not-installed}] - Boot Device Operational Status

    Displays information only about the storage shelves with boot devices that match the specified operational status.

    [-coin-battery-module-id {A|B}] - Coin Battery Module ID

    Displays information only about the storage shelves with coin batteries from the specified module.

    [-coin-battery-id <integer>,…​] - Coin Battery ID

    Displays information only about the storage shelves with coin batteries that match the specified ID.

    [-coin-battery-voltage <integer>,…​] - Coin Battery Voltage (mV)

    Displays information only about the storage shelves with coin batteries that match the specified voltage.

    [-coin-battery-op-status {unknown|normal|error|low|high|not-supported|not-installed}] - Coin Battery Operational Status

    Displays information only about the storage shelves with coin batteries that match the specified operational status.

    [-error-type {Unknown|ACPP|Bootdevice|Coinbattery|Configuration|Current|Dimm|Expander|Fan|Module|PCM|Power|Temperature|Voltage}] - Error Type

    Displays information only about the storage shelves with errors that match the error type you specify.

    [-error-severity {unknown|notice|warning|error|critical}] - Error Severity

    Displays information only about the storage shelves with errors that match the error severity you specify.

    Examples

    The following example displays information about all storage shelves:

    cluster1::> storage shelf show
    Module  Operational
               Shelf Name  Shelf ID  Serial Number    Model        Type    Status
        -----------------  --------  ---------------  -----------  ------  -----------
                      1.1         1  6000832415       DS2246       IOM6    Critical
                      1.2         2  6000647652       DS2246       IOM6    Normal
                      1.3         3  6000003844       DS2246       IOM6    Normal
                      1.4         4  SHJ000000013A9E  DS4246       IOM6    Normal
                      1.5         5  SHJ000000013A84  DS4246       IOM6    Normal
                      1.6         6  6000005555       DS2246       IOM6    Normal
        6 entries were displayed.
    cluster1::>

    The following example displays expanded information about a storage shelf named 1.2:

    cluster1::> storage shelf show -shelf 1.2 -instance
    Shelf Name: 1.2
                     Stack ID: 1
                     Shelf ID: 2
                    Shelf UID: 50:0a:09:80:01:b9:75:41
                Serial Number: 6000647652
                  Module Type: IOM6
                        Model: DS2246
                 Shelf Vendor: NETAPP
                   Disk Count: 12
              Connection Type: SAS
                  Shelf State: Online
                       Status: Normal
    Modules:                                          Module is
                                         Monitor   Is     Reporting FW Update             Latest   Swap Operational Module
         ID Part No.     ES Serial No.   is Active Master Element   Progress      FW Rev. FW Rev. Count Status      Location
        --- ------------ --------------- --------- ------ --------- ------------- ------- ------- ----- ----------- --------------
          a 111-00190+A0 8006437891      true      false  false     not-available 0191    -           0 normal      rear of the shelf at the top left
          b 111-00190+A0 8006435180      true      true   true      not-available 0191    -           0 normal      rear of the shelf at the top right
    Paths:
                                                                                                                     Speed
        Controller         Initiator Initiator Side Switch Port Target Side Switch Port    Target Port        TPGN    Gb/s I/O KB/s    IOPS
        ------------------ --------- -------------------------- -------------------------- ------------------ ------ ----- -------- -------
        stsw-8020-01       0a        -                          -                          -                  -          -        -       -
        stsw-8020-01       2b        -                          -                          -                  -          -        -       -
        stsw-8020-02       0a        -                          -                          -                  -          -        -       -
        stsw-8020-02       2b        -                          -                          -                  -          -        -       -
    Power Supply Units:
                                                             Crest  Power   Reset   PSU              Operational
         ID Type Part#        Serial#         Power Rating   Factor Drawn   Capable Enabled Firmware Status           PSU Location
        --- ---- ------------ --------------- -------------- ------ ------- ------- ------- -------- ---------------- ------------------------
          1 9C   114-00065+A1 XXT131052637    -              -      -       false   true    020F     normal           rear of the shelf at the bottom left
          2 9C   114-00065+A1 XXT131052551    -              -      -       false   true    020F     normal           rear of the shelf at the bottom right
    Voltage Sensors:
            Voltage Operational
         ID     (V) Status                 Sensor Location
        --- ------- ---------------------- ------------------------
          1    5.70 normal                 rear of the shelf on the lower left power supply
          2  12.300 normal                 rear of the shelf on the lower left power supply
          3    5.70 normal                 rear of the shelf on the lower right power supply
          4  12.180 normal                 rear of the shelf on the lower right power supply
    Current Sensors:
            Current Operational
         ID    (mA) Status                 Sensor Location
        --- ------- ---------------------- ------------------------
          1       0 normal                 rear of the shelf on the lower left power supply
          2       0 normal                 rear of the shelf on the lower left power supply
          3       0 normal                 rear of the shelf on the lower right power supply
          4       0 normal                 rear of the shelf on the lower right power supply
    Fans:
             Speed Operational
         ID  (RPM) Status                  Fan Location
        --- ------ ----------------------- ----------------------
          1   3000 normal                  rear of the shelf on the lower left power supply
          2   2970 normal                  rear of the shelf on the lower left power supply
          3   3000 normal                  rear of the shelf on the lower right power supply
          4   2970 normal                  rear of the shelf on the lower right power supply
    Temperature:
                         -- Thresholds °C --
            Temp Is       Low  Low High High Operational
         ID   °C Ambient Crit Warn Crit Warn Status             Sensor Location
        --- ---- ------- ---- ---- ---- ---- ------------------ --------------------------------
          1   23 true       0    5   42   40 normal             front of the shelf on the left, on the OPS panel
          2   26 false      5   10   55   50 normal             inside of the shelf on the midplane
          3   24 false      5   10   55   50 normal             rear of the shelf on the lower left power supply
          4   39 false      5   10   70   65 normal             rear of the shelf on the lower left power supply
          5   25 false      5   10   55   50 normal             rear of the shelf on the lower right power supply
          6   36 false      5   10   70   65 normal             rear of the shelf on the lower right power supply
          7   25 false      5   10   60   55 normal             rear of the shelf at the top left, on shelf module A
          8   26 false      5   10   60   55 normal             rear of the shelf at the top right, on shelf module B
    SAS Ports:
                                              -- Port Speeds Gb/s -- Power  Port
        Phy # IOM Port Type WWPN              Operational Negotiated Status Status
        ----- --- --------- ----------------- ----------- ---------- ------ -----------
            0  A  Square    500a098004b063b0          6.0          - -      Enabled
            1  A  Square    500a098004b063b0          6.0          - -      Enabled
            2  A  Square    500a098004b063b0          6.0          - -      Enabled
            3  A  Square    500a098004b063b0          6.0          - -      Enabled
            4  A  Circle    500a09800569f03f          6.0          - -      Enabled
            5  A  Circle    500a09800569f03f          6.0          - -      Enabled
            6  A  Circle    500a09800569f03f          6.0          - -      Enabled
            7  A  Circle    500a09800569f03f          6.0          - -      Enabled
            8  A  Disk      500605ba00c1cb8d          6.0        6.0 on     Enabled
            9  A  Disk      500605ba00c1ea8d          6.0        6.0 on     Enabled
           10  A  Disk      500605ba00c1d111          6.0        6.0 on     Enabled
           11  A  Disk      500605ba00c1bc49          6.0        6.0 on     Enabled
           12  A  Disk      500605ba00c1cdfd          6.0        6.0 on     Enabled
           13  A  Disk      500605ba00c1c531          6.0        6.0 on     Enabled
           14  A  Disk      500605ba00c1eb05          6.0        6.0 on     Enabled
           15  A  Disk      500605ba00c1ec29          6.0        6.0 on     Enabled
           16  A  Disk      500605ba00c1bc29          6.0        6.0 on     Enabled
           17  A  Disk      500605ba00c1c471          6.0        6.0 on     Enabled
           18  A  Disk      500605ba00c039a9          6.0        6.0 on     Enabled
           19  A  Disk      500605ba00c1c4dd          6.0        6.0 on     Enabled
           20  A  Disk      -                           -          - -      Empty
           21  A  Disk      -                           -          - -      Empty
           22  A  Disk      -                           -          - -      Empty
           23  A  Disk      -                           -          - -      Empty
           24  A  Disk      -                           -          - -      Empty
           25  A  Disk      -                           -          - -      Empty
           26  A  Disk      -                           -          - -      Empty
           27  A  Disk      -                           -          - -      Empty
           28  A  Disk      -                           -          - -      Empty
           29  A  Disk      -                           -          - -      Empty
           30  A  Disk      -                           -          - -      Empty
           31  A  Disk      -                           -          - -      Empty
           32  A  SIL       -                           -          - -      Disabled
           33  A  SIL       -                           -          - -      Disabled
           34  A  SIL       -                           -          - -      Disabled
           35  A  SIL       -                           -          - -      Disabled
            0  B  Square    500a098004af9e30          6.0          - -      Enabled
            1  B  Square    500a098004af9e30          6.0          - -      Enabled
            2  B  Square    500a098004af9e30          6.0          - -      Enabled
            3  B  Square    500a098004af9e30          6.0          - -      Enabled
            4  B  Circle    500a098005688dbf          6.0          - -      Enabled
            5  B  Circle    500a098005688dbf          6.0          - -      Enabled
            6  B  Circle    500a098005688dbf          6.0          - -      Enabled
            7  B  Circle    500a098005688dbf          6.0          - -      Enabled
            8  B  Disk      500605ba00c1cb8e          6.0        6.0 on     Enabled
            9  B  Disk      500605ba00c1ea8e          6.0        6.0 on     Enabled
           10  B  Disk      500605ba00c1d112          6.0        6.0 on     Enabled
           11  B  Disk      500605ba00c1bc4a          6.0        6.0 on     Enabled
           12  B  Disk      500605ba00c1cdfe          6.0        6.0 on     Enabled
           13  B  Disk      500605ba00c1c532          6.0        6.0 on     Enabled
           14  B  Disk      500605ba00c1eb06          6.0        6.0 on     Enabled
           15  B  Disk      500605ba00c1ec2a          6.0        6.0 on     Enabled
           16  B  Disk      500605ba00c1bc2a          6.0        6.0 on     Enabled
           17  B  Disk      500605ba00c1c472          6.0        6.0 on     Enabled
           18  B  Disk      500605ba00c039aa          6.0        6.0 on     Enabled
           19  B  Disk      500605ba00c1c4de          6.0        6.0 on     Enabled
           20  B  Disk      -                           -          - -      Empty
           21  B  Disk      -                           -          - -      Empty
           22  B  Disk      -                           -          - -      Empty
           23  B  Disk      -                           -          - -      Empty
           24  B  Disk      -                           -          - -      Empty
           25  B  Disk      -                           -          - -      Empty
           26  B  Disk      -                           -          - -      Empty
           27  B  Disk      -                           -          - -      Empty
           28  B  Disk      -                           -          - -      Empty
           29  B  Disk      -                           -          - -      Empty
           30  B  Disk      -                           -          - -      Empty
           31  B  Disk      -                           -          - -      Empty
           32  B  SIL       -                           -          - -      Disabled
           33  B  SIL       -                           -          - -      Disabled
           34  B  SIL       -                           -          - -      Disabled
           35  B  SIL       -                           -          - -      Disabled
    FC Ports:
                      Port
         ID Port Type Status
        --- --------- -----------
          - -         -
    Bays:
    Has               Operational
         ID Disk  Bay Type    Status
        --- ----- ----------- -----------
          0 true  single-disk normal
          1 true  single-disk normal
          2 true  single-disk normal
          3 true  single-disk normal
          4 true  single-disk normal
          5 true  single-disk normal
          6 true  single-disk normal
          7 true  single-disk normal
          8 true  single-disk normal
          9 true  single-disk normal
         10 true  single-disk normal
         11 true  single-disk normal
         12 false single-disk normal
         13 false single-disk normal
         14 false single-disk normal
         15 false single-disk normal
         16 false single-disk normal
         17 false single-disk normal
         18 false single-disk normal
         19 false single-disk normal
         20 false single-disk normal
         21 false single-disk normal
         22 false single-disk normal
         23 false single-disk normal
    cluster1::>

    The following example displays information about the power supplies, voltage sensors and current sensors of the storage shelf 1.1:

    cluster1::> storage shelf show -shelf 1.1 -power
    Shelf Name: 1.1
                     Stack ID: 1
                     Shelf ID: 1
                    Shelf UID: 50:0a:09:80:01:cb:d6:84
                Serial Number: 6000832415
                  Module Type: IOM6
                        Model: DS2246
                 Shelf Vendor: NETAPP
                   Disk Count: 12
              Connection Type: SAS
                  Shelf State: Online
                       Status: Normal
    Power Supply Units:
                                                             Crest  Power   Reset   PSU              Operational
         ID Type Part#        Serial#         Power Rating   Factor Drawn   Capable Enabled Firmware Status
        --- ---- ------------ --------------- -------------- ------ ------- ------- ------- -------- ---------------------
          1 9C   114-00065+A1 XXT132835072    -              -      -       false   true    020F     normal
          2 9C   114-00065+A1 XXT132835073    -              -      -       false   true    020F     normal
    Voltage Sensors:
            Voltage Operational
         ID     (V) Status
        --- ------- ----------------------
          1    5.70 normal
          2  12.180 normal
          3    5.70 normal
          4  12.300 normal
    Current Sensors:
            Current Operational
         ID    (mA) Status
        --- ------- ----------------------
          1       0 normal
          2       0 normal
          3    3900 normal
          4       0 normal
    Errors:
        ------
        Critical condition is detected in storage shelf power supply unit "1". The unit might fail.
        Critical over temperature failure for temperature sensor "1". Current temperature: "75" C ("167" F).
    cluster1::>

    The following example displays information about the cooling elements and temperature sensors inside the storage shelf 1.2:

    cluster1::> storage shelf show -shelf 1.2 -cooling
    Shelf Name: 1.2
                     Stack ID: 1
                     Shelf ID: 2
                    Shelf UID: 50:0a:09:80:01:b9:75:41
                Serial Number: 6000647652
                  Module Type: IOM6
                        Model: DS2246
                 Shelf Vendor: NETAPP
                   Disk Count: 12
              Connection Type: SAS
                  Shelf State: Online
                       Status: Normal
    Fans:
           Speed Operational
        ID (RPM) Status
        -- ----- -------------
         1  3000 normal
         2  3000 normal
         3  3000 normal
         4  2970 normal
    Temperature:
                     -- Thresholds °C --
            Temp Is       Low  Low High High Operational
         ID   °C Ambient Crit Warn Crit Warn Status
        --- ---- ------- ---- ---- ---- ---- ------------------
          1   23 true       0    5   42   40 normal
          2   26 false      5   10   55   50 normal
          3   24 false      5   10   55   50 normal
          4   39 false      5   10   70   65 normal
          5   25 false      5   10   55   50 normal
          6   36 false      5   10   70   65 normal
          7   25 false      5   10   60   55 normal
          8   27 false      5   10   60   55 normal
    Errors:
        ------
        -
    cluster1::>

    The following example displays information about the connectivity from the node to the storage shelf 1.2:

    cluster1::> storage shelf show -shelf 1.2 -connectivity
                   Shelf Name: 1.2
                     Stack ID: 1
                     Shelf ID: 2
                    Shelf UID: 50:0a:09:80:01:b9:75:41
                Serial Number: 6000647652
                  Module Type: IOM6
                        Model: DS2246
                 Shelf Vendor: NETAPP
                   Disk Count: 12
              Connection Type: SAS
                  Shelf State: Online
                       Status: Normal
    Paths:
    Controller         Initiator Initiator Side Switch Port Target Side Switch Port    Target Port        TPGN
        ------------------ --------- -------------------------- -------------------------- ------------------ ------
        stsw-8020-01       0a        -                          -                          -                  -
        stsw-8020-01       2b        -                          -                          -                  -
        stsw-8020-02       0a        -                          -                          -                  -
        stsw-8020-02       2b        -                          -                          -                  -
    Errors:
        ------
        -
    cluster1::>

    The following example displays information about the disk bays of the storage shelf 1.2:

    cluster1::> storage shelf show -shelf 1.2 -bay
    Shelf Name: 1.2
                         Stack ID: 1
                         Shelf ID: 2
                        Shelf UID: 50:0a:09:80:01:b9:75:41
                    Serial Number: 6000647652
                      Module Type: IOM6
                            Model: DS2246
                     Shelf Vendor: NETAPP
                       Disk Count: 12
                  Connection Type: SAS
                      Shelf State: Online
                           Status: Normal
    Bays:
    Has               Operational
         ID Disk  Bay Type    Status
        --- ----- ----------- -----------
          0 true  single-disk normal
          1 true  single-disk normal
          2 true  single-disk normal
          3 true  single-disk normal
          4 true  single-disk normal
          5 true  single-disk normal
          6 true  single-disk normal
          7 true  single-disk normal
          8 true  single-disk normal
          9 true  single-disk normal
         10 true  single-disk normal
         11 true  single-disk normal
         12 false single-disk normal
         13 false single-disk normal
         14 false single-disk normal
         15 false single-disk normal
         16 false single-disk normal
         17 false single-disk normal
         18 false single-disk normal
         19 false single-disk normal
         20 false single-disk normal
         21 false single-disk normal
         22 false single-disk normal
         23 false single-disk normal
    Errors:
        ------
        -
    cluster1::>

    The following example displays information about the ports of the storage shelf 1.2:

    cluster1::> storage shelf show -shelf 1.2 -port
    Shelf Name: 1.2
                     Stack ID: 1
                     Shelf ID: 2
                    Shelf UID: 50:0a:09:80:01:b9:75:41
                Serial Number: 6000647652
                  Module Type: IOM6
                        Model: DS2246
                 Shelf Vendor: NETAPP
                   Disk Count: 12
              Connection Type: SAS
                  Shelf State: Online
                       Status: Normal
    SAS Ports:
                                              -- Port Speeds Gb/s -- Power  Port
        Phy # IOM Port Type WWPN              Operational Negotiated Status Status
        ----- --- --------- ----------------- ----------- ---------- ------ -----------
            0  A  Square    500a098004b063b0          6.0          - -      Enabled
            1  A  Square    500a098004b063b0          6.0          - -      Enabled
            2  A  Square    500a098004b063b0          6.0          - -      Enabled
            3  A  Square    500a098004b063b0          6.0          - -      Enabled
            4  A  Circle    500a09800569f03f          6.0          - -      Enabled
            5  A  Circle    500a09800569f03f          6.0          - -      Enabled
            6  A  Circle    500a09800569f03f          6.0          - -      Enabled
            7  A  Circle    500a09800569f03f          6.0          - -      Enabled
            8  A  Disk      500605ba00c1cb8d          6.0        6.0 on     Enabled
            9  A  Disk      500605ba00c1ea8d          6.0        6.0 on     Enabled
           10  A  Disk      500605ba00c1d111          6.0        6.0 on     Enabled
           11  A  Disk      500605ba00c1bc49          6.0        6.0 on     Enabled
           12  A  Disk      500605ba00c1cdfd          6.0        6.0 on     Enabled
           13  A  Disk      500605ba00c1c531          6.0        6.0 on     Enabled
           14  A  Disk      500605ba00c1eb05          6.0        6.0 on     Enabled
           15  A  Disk      500605ba00c1ec29          6.0        6.0 on     Enabled
           16  A  Disk      500605ba00c1bc29          6.0        6.0 on     Enabled
           17  A  Disk      500605ba00c1c471          6.0        6.0 on     Enabled
           18  A  Disk      500605ba00c039a9          6.0        6.0 on     Enabled
           19  A  Disk      500605ba00c1c4dd          6.0        6.0 on     Enabled
           20  A  Disk      -                           -          - -      Empty
           21  A  Disk      -                           -          - -      Empty
           22  A  Disk      -                           -          - -      Empty
           23  A  Disk      -                           -          - -      Empty
           24  A  Disk      -                           -          - -      Empty
           25  A  Disk      -                           -          - -      Empty
           26  A  Disk      -                           -          - -      Empty
           27  A  Disk      -                           -          - -      Empty
           28  A  Disk      -                           -          - -      Empty
           29  A  Disk      -                           -          - -      Empty
           30  A  Disk      -                           -          - -      Empty
           31  A  Disk      -                           -          - -      Empty
           32  A  SIL       -                           -          - -      Disabled
           33  A  SIL       -                           -          - -      Disabled
           34  A  SIL       -                           -          - -      Disabled
           35  A  SIL       -                           -          - -      Disabled
            0  B  Square    500a098004af9e30          6.0          - -      Enabled
            1  B  Square    500a098004af9e30          6.0          - -      Enabled
            2  B  Square    500a098004af9e30          6.0          - -      Enabled
            3  B  Square    500a098004af9e30          6.0          - -      Enabled
            4  B  Circle    500a098005688dbf          6.0          - -      Enabled
            5  B  Circle    500a098005688dbf          6.0          - -      Enabled
            6  B  Circle    500a098005688dbf          6.0          - -      Enabled
            7  B  Circle    500a098005688dbf          6.0          - -      Enabled
            8  B  Disk      500605ba00c1cb8e          6.0        6.0 on     Enabled
            9  B  Disk      500605ba00c1ea8e          6.0        6.0 on     Enabled
           10  B  Disk      500605ba00c1d112          6.0        6.0 on     Enabled
           11  B  Disk      500605ba00c1bc4a          6.0        6.0 on     Enabled
           12  B  Disk      500605ba00c1cdfe          6.0        6.0 on     Enabled
           13  B  Disk      500605ba00c1c532          6.0        6.0 on     Enabled
           14  B  Disk      500605ba00c1eb06          6.0        6.0 on     Enabled
           15  B  Disk      500605ba00c1ec2a          6.0        6.0 on     Enabled
           16  B  Disk      500605ba00c1bc2a          6.0        6.0 on     Enabled
           17  B  Disk      500605ba00c1c472          6.0        6.0 on     Enabled
           18  B  Disk      500605ba00c039aa          6.0        6.0 on     Enabled
           19  B  Disk      500605ba00c1c4de          6.0        6.0 on     Enabled
           20  B  Disk      -                           -          - -      Empty
           21  B  Disk      -                           -          - -      Empty
           22  B  Disk      -                           -          - -      Empty
           23  B  Disk      -                           -          - -      Empty
           24  B  Disk      -                           -          - -      Empty
           25  B  Disk      -                           -          - -      Empty
           26  B  Disk      -                           -          - -      Empty
           27  B  Disk      -                           -          - -      Empty
           28  B  Disk      -                           -          - -      Empty
           29  B  Disk      -                           -          - -      Empty
           30  B  Disk      -                           -          - -      Empty
           31  B  Disk      -                           -          - -      Empty
           32  B  SIL       -                           -          - -      Disabled
           33  B  SIL       -                           -          - -      Disabled
           34  B  SIL       -                           -          - -      Disabled
           35  B  SIL       -                           -          - -      Disabled
    FC Ports:
                      Port
         ID Port Type Status
        --- --------- -----------
          - -         -
    Errors:
        ------
        -
    cluster1::>

    The following example displays error information about the storage shelves that have errors:

    cluster1::> storage shelf show -errors
    Shelf Name: 1.1
             Shelf UID: 50:0a:09:80:01:cb:d6:84
         Serial Number: 6000832415
    Error Type          Description
        ------------------  ---------------------------
        Power               Critical condition is detected in storage shelf power supply unit "1". The unit might fail.
        Temperature         Critical over temperature failure for temperature sensor "1". Current temperature: "75" C ("167" F).
    Top of Page