ONTAP 9.12.1 commands

50←PDF
  • ONTAP 9.12.1 commands(CA08871-263en.pdf)
  • system controller pci show

    Display the PCI Device Table

    Availability: This command is available to cluster administrators at the admin privilege level.

    Description

    The system controller pci show command displays details of the PCI devices present in all of the nodes in a cluster. These commands are available for 80xx, 25xx and later systems. Earlier models are not supported. By default, the command displays the following information about the PCI devices:

    • Node name

    • Display name

    • Correctable error count

    • Functional link width

    • Functional link speed

    • Health monitor status

      To display more details, use the -instance parameter.

    Parameters

    { [-fields <fieldname>,…​]

    Selects the fields that you specify.

    | [-instance ] }

    Displays detailed information for all of the PCI devices.

    [-node {<nodename>|local}] - Node

    Selects the PCI devices that are present in the specified node.

    [-bus-number <integer>] - Bus Number

    Selects the PCI devices with the specified bus number.

    [-device-number <integer>] - Device Number

    Selects the PCI devices with the specified device number.

    [-function-number <integer>] - Function Number

    Selects the PCI devices with the specified function number.

    [-slot-number <integer>] - Slot Info

    Selects the PCI devices with the specified slot number.

    [-monitor {node-connect|system-connect|system|controller|chassis|cluster-switch|example|ethernet-switch}] - Health Monitor Name

    Selects the PCI devices monitored by the specified health monitor.

    [-vendor-id <Hex Integer>] - Vendor ID

    Selects the PCI devices with the specified vendor ID.

    [-device-id <Hex Integer>] - Device ID

    Selects the PCI devices with the specified device ID.

    [-physical-link-width <integer>] - Physical Link Width

    Selects the PCI devices with the specified physical link width.

    [-functional-link-width <integer>] - Functional Link Width

    Selects the PCI devices with the specified functional link width.

    [-physical-link-speed <text>] - Physical Link Speed(GT/s)

    Selects the PCI devices with the specified physical link speed.

    [-functional-link-speed <text>] - Functional Link Speed(GT/s)

    Selects the PCI devices with the specified functional link speed.

    [-unique-name <text>] - Unique Name

    Selects the PCI devices with the specified unique name.

    [-corr-err-count <integer>] - Correctable Error Count

    Selects the PCI devices with the specified correctable error count.

    [-health {ok|ok-with-suppressed|degraded|unreachable|unknown}] - Status

    Selects the PCI devices with the specified health monitor status.

    [-display-name <text>] - Display Name

    Selects the PCI devices with the specified display name.

    [-cerr-diff <integer>] - Correctable Error Difference

    Selects the PCI devices with the specified difference in correctable error count.

    Examples

    The example below displays the information about the PCIe devices present in all of the nodes in the cluster.

    cluster1::> system controller pci show
                  Display                  Correctable Functional Functional
    Node          Name                     Error Count Link Width Link Speed Status
    ------------- ------------------------ ----------- ---------- ---------- ------
    cluster1-01   Ontap PCI Device 0                 0          4      5GT/s ok
    cluster1-02   Ontap PCI Device 4                 0          4      5GT/s ok

    The example below displays detailed information about a PCIe device in a node.

    cluster1::> system controller pcie show -instance -node cluster1-01 -bus-number 1
    Node: cluster1-01
                      Bus Number: 1
                   Device Number: 0
                 Function Number: 0
                       Slot Info: 0
             Health Monitor Name: controller
                       Vendor ID: 11f8
                       Device ID: 8001
             Physical Link Width: 4
           Functional Link Width: 4
       Physical Link Speed(GT/s): 5GT/s
     Functional Link Speed(GT/s): 5GT/s
                     Unique Name: ontap0@pci0:1:0:0
         Correctable Error Count: 0
                          Status: ok
                    Display Name: Ontap PCI Device 0
    Correctable Error Difference: 0
    Top of Page