Test asynchronous mirror group connectivity
The diagnose asyncMirrorGroup
command tests possible communication problems between the local storage system and the remote storage system associated with an asynchronous mirror group.
Supported Series
This command applies to any individual storage system, with some restrictions.
If you are running the command on the HB2100/HB2200/HB2300 or HB5100/HB5200 series, the client type must be set to |
Roles
To execute this command on an HB2100/HB2200/HB2300 or HB5100/HB5200 storage system, you must have the Storage Admin role.
Syntax
diagnose asyncMirrorGroup [asyncMirrorGroupName] testID=(all | connectivity | latency | bandwidth | portConnections)
Parameter
Parameter | Description |
---|---|
|
The name of an existing asynchronous mirror group that you want to test. Enclose the asynchronous mirror group name in square brackets ([ ]). If the asynchronous mirror group name has special characters or numbers, you must enclose the asynchronous mirror group name in double quotation marks (" ") inside square brackets. |
|
The identifier for the diagnostic test you want to run. The identifier and corresponding tests are as follows:
|