SANtricity 11.9 Commands ( CA08871-194 ~ 196 )

Reset storage system InfiniBand statistics baseline

The reset storageArray ibStatsBaseline command resets the InfiniBand statistics baseline to 0 for the storage system.

Supported Series

This command applies to any individual storage system, including the ETERNUS AB2100/AB2200, ETERNUS HB1100/HB1200/HB1300/HB1400, ETERNUS HB2100/HB2200/HB2300/HB2400/HB2500/HB2600, and ETERNUS HB5100/HB5200, as long as all SMcli packages are installed.

Roles

To execute this command on the ETERNUS AB/HB series storage system, you must have the Storage Admin role.

This command is deprecated and is replaced by the Reset storage system host port statistics baseline command.

Syntax

reset storageArray ibStatsBaseline

Parameters

None.

Notes

This command does not actually reset the raw counts maintained in the hardware and firmware. Instead, the firmware creates a snapshot of the current counter values and uses these values to report differences in the counts when the statistics are retrieved. The new baseline time is applied to both controllers so that the controller counts are synchronized with each other. If one controller resets without the other controller resetting, the counters are no longer synchronized. The client becomes aware that the controllers are not synchronized because the timestamp data reported along with the statistics is not the same for both controllers.

Minimum firmware level

11.80 adds ETERNUS AB3100 and ETERNUS AB6100 system support

Top of Page