SANtricity 11.8 Commands ( CA08871-194 ~ 196 )

Suspend synchronous mirroring

The suspend syncMirror primaries command suspends a synchronous mirroring operation.

Supported Series

This command applies to any individual storage system, including the HB2100/HB2200/HB2300, HB5100/HB5200, AB6100 and AB3100 series, as long as all SMcli packages are installed.

Roles

To execute this command on an HB2100/HB2200/HB2300, HB5100/HB5200, AB6100 or AB3100 storage system, you must have the Storage Admin role.

Context

In previous versions of this command the feature identifier was remoteMirror. This feature identifier is no longer valid and is replaced by syncMirror.

Syntax

suspend syncMirror (primary [primaryVolumeName]
primaries [primaryVolumeName1 ... primaryVolumeNameN)]
[writeConsistency=(TRUE | FALSE)]

Parameters

Parameter Description

primary

The name of the primary volume for which you want to suspend operation. Enclose the volume name in square brackets ([ ]). If the volume name has special characters or numbers, you must enclose the volume name in double quotation marks (" ") inside square brackets.

primaries

The names of several primary volumes for which you want to suspend operations. All of the volumes will have the same properties. Enter the names of the volumes using these rules:

  • Enclose all of the names in square brackets ([ ]).

  • Separate each of the names with a space.

If the volume names have special characters or numbers, enter the names using these rules:

  • Enclose all of the names in square brackets ([ ]).

  • Enclose each of the names in double quotation marks (" ").

  • Separate each of the names with a space.

writeConsistency

This parameter defines whether the volumes identified in this command are in a write-consistency group or are separate. For the volumes in the same write-consistency group, set this parameter to TRUE. For the volumes that are separate, set this parameter to FALSE.

Notes

If you set the writeConsistency parameter to TRUE, the volumes must be in a write-consistency group (or groups). This command suspends all write-consistency groups that contain the volumes. For example, if volumes A, B, and C are in a write-consistency group and they have remote counterparts A’, B’, and C’, the command:

suspend syncMirror volume ["A"] writeConsistency=TRUE

suspends A-A’, B-B’, and C-C’. If you have a write-consistency group 1={A, B, C} and write-consistency group 2={D, E, F}, the command:

suspend syncMirror volumes ["A" "D"] writeConsistency=TRUE

suspends both write-consistency groups.

Minimum firmware level

11.80 adds AB6100 and AB3100 system support

Top of Page