SANtricity 11.8 Commands

to Japanese version

Save check volume parity job parity errors

The save check volume parity job parity errors command saves the parity errors logged by a check volume parity job to the specified file. The output file is written in the same format as the deprecated check volume parity command, and therefore can be used as input to the existing repair volume parity command.

Supported Systems

This command applies to any individual storage array, including the AB6100 and AB3100 systems; as long as all SMcli packages are installed.

Roles

To execute this command on an AB6100 and Ab3100 system, you must have the Storage Admin role.

Syntax

save check volume parity job parityErrors jobId=<job_id> parityErrorFile=<parity_error_file>;

Parameters

Parameter Description

jobId

The job id for which to retrieve and save logged parity errors. This value is required.

parityErrorFile

The file specified by the user to indicate where the logged parity errors should be saved. This value is required.

Minimum firmware level

11.80

Top of Page