ONTAP 9 Manuals ( CA08871-402 )

Manually Fast zero drives

On systems freshly installed with ONTAP 9.7 or later and systems reinitialized with ONTAP 9.7 or later, fast zeroing is used to zero drives.

With fast zeroing, drives are zeroed in seconds. This is done automatically before provisioning and greatly reduces the time it takes to initialize the system, create aggregates, or expand aggregates when spare drives are added.

Fast zeroing is supported on both SSDs and HDDs.

Fast zeroing must be freshly installed or the system must be reinitialized.

If you need to manually zero a drive, you can use one of the following methods. In ONTAP 9.7 and later, manually zeroing a drive also takes only seconds.

CLI command

Use a CLI command to fast-zero drives

About this task

Admin privileges are required to use this command.

Steps
  1. Enter the CLI command:

    storage disk zerospares
Boot menu options

Select options from the boot menu to fast-zero drives

Steps
  1. From the boot menu, select one of the following options:

    • (4) Clean configuration and initialize all disks

    • (9a) Unpartition all disks and remove their ownership information

    • (9b) Clean configuration and initialize node with whole disks

Top of Page