SAN configurations in a MetroCluster environment

You must be aware of certain considerations when using SAN configurations in a MetroCluster environment.

  • MetroCluster configurations do not support front-end FC fabric “routed” vSAN configurations.

  • Beginning with ONTAP 9.12.1, four-node MetroCluster IP configurations are supported on NVMe/FC. MetroCluster configurations are not supported for NVMe prior to ONTAP 9.12.1.

  • Other SAN protocols such as iSCSI, FC, and FCoE are supported on MetroCluster configurations.

  • When using SAN client configurations, you must check whether any special considerations for MetroCluster configurations are included in the notes that are provided by Fujitsu support personnel.

  • Operating systems and applications must provide an I/O resiliency of 120 seconds to support MetroCluster automatic unplanned switchover and Tiebreaker or Mediator-initiated switchover.

  • The MetroCluster is using the same WWPNs on both sides of the front-end SAN.